Loading...
HomeMy WebLinkAboutWPO201600021 Plan - VSMP WPO VSMP 2016-09-14R L_ -TWA "iPLIV, COUNTY OF ALBEMARLE, VIRGINIA SITE DATA: TAX MAP PARCEL: TM 44-12W (DB 1937 PG 255) AND TM 44-12F (DB 1937 PG 255) ZONING: RA MAGISTERIAL DISTRICT: JACK JOUETT PROJECT AREA: 23.011 ACRES SOURCE OF BOUNDARY AND TOPOGRAPHY: TIMMONS GROUP. 2815 N AUGUSTA ST SUITE C STAUNTON, VA 24401 (540) 885-0920 COMPLETED ON NOVEMBER, 23 2015 DATUM: HORIZONTAL: BASED ON NAD83, VIRGINIA STATE GRID SOUTH ZONE. VERTICAL: BASED ON NAVD 88, ESTABLISHED THROUGH LEICA SMARTNET. BUILDING SETBACKS: FRONT: 75 FT FROM EXISTING PUBLIC ROAD FRONT - LOTS 1, 3, 4, 7 & 8: 25 FT FROM INTERNAL ROADS FRONT - LOTS 5 & 6: 65 FT FROM INTERNAL ROADS SIDE: 25 FT REAR: 35 FT LOT FRONTAGE: EACH LOT MUST HAVE AT LEAST 150' OF FRONTAGE AILONG THE PROPOSED ROAD AND/OR 250' OF FRONTAGE ALONG WOODLANDS ROAD. ALLOWABLE DENSITY: TM 44-12W CONTAINS 3 DEVELOPMENT RIGHTS + TM 44-12F CONTAINS 5 DEVELOPMENT RIGHTS TOTAL LOTS ALLOWED: 8 LOTS DEVELOPMENT RIGHTS REMAINING: LOTS 1, AND 3-8 ARE ASSIGNED 1 DEVELOPMENT RIGHT EACH AND MAY NOT BE FURTHER DIVIDED. THE RESIDUE OF TAX MAP/PARCEL 44-12W (LOT 2) IS RETAINING 1 DEVELOPMENT RIGHT AND MAY NOT BE FURTHER DIVIDED. PROPOSED USES: 8 SINGLE FAMILY UNITS MAXIMUM GROSS DENSITY ALLOWED: 0.5 D.U. / ACRE. GROSS DENSITY PROVIDED: 8 LOTS / 23.011 ACRES = 0.348 D.U. / ACRE:. LOT SIZE: 2.0 ACRE MINIMUM LOT SIZE (BY RIGHT DEVELOPMENT) PARKING: ALL PARKING SHALL BE LOCATED OFF STREET IN DRIVEWAY'S AND GARAGES. PHASING: PROJECT SHALL BE BUILT IN ONE PHASE. BUILDING SITES: LOTS 1-8 MAY NOT BE FURTHER DIVIDED. ONLY 1 DWE=LLING UNIT PER LOT SHALL BE ALLOWED. BURIAL SITES: NO CEMETERIES FOUND ON SITE. WATER SUPPLY WATERSHED: THIS SITE LIES WITHIN THE ALBEMARLE: COUNTY SOUTH FORK RIVANNA RESERVOIR WATER SUPPLY WATERSHED. WETLAND IMPACTS: NONE WATER SUPPLY AND UTILITIES: UNDERCURRENT COUNTY POLICY, PUBLIC WATER AND/OR SEWER WILL NOT BE AVAILABLE TO THIS PROPERTY. ALL LOTS WILL BE SERVED BY INDIVIDUAL DRAIN FIELDS AND WELLS. STORMWATER: WATER QUALITY REQUIREMENTS AND FLOW ATTENUA71ON WILL BE ACHIEVED THROUGH AN ONSITE DETENTION SYSTEM. AGRICULTURAL/FOREST DISTRICT: NONE FLOOD PLAIN: BASED ON FEMA FLOOD INSURANCE RATE MAP (FIRM), MAP NUMBER 51003CO260D, EFFECTIVE 4, 2005, THE PROPERTY SHOWN LIES IN UNSHADED ZONE'X', AREAS DETERMINED Tf0 BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. BUILDING SITE NOTE: EACH PROPOSED LOT CONTAIN A BUILDING SITE THAT COMPLIES WITH SECTION 4.2.1 OF THE ALBEMARLE COUNTY ZONING ORDINANCE. ALBEMARLE COUNTY EXCEPTION: ON MARCH 11, 2016 THE SUBDIVISION AGENT GRANTED LOT 2 AN EXCEPTION TO SECTION 14-404(A) TO CONTINUE UTILIZING THE EXISTING DRIVEWAY ACCESSING WOODLANDS ROAD (SR 676) WITH A CONDITION THAT ADEQUATE SIGHT DISTANCE FOR THE PRIVATE ENTRANCE SHALL BE DEPICTED ON THE ROAD PLAN. PARCEL AREA SUMMARY: PUBLIC R/W: 0.971 AC PUBLIC R/W DEDICATION FOR WOODLANDS ROAD: 0.425 AC PROPOSED LOTS: 21.615 AC TOTAL SITE AREA: 23.011 ACRES ALL PROPOSED STORMWATER MANAGEMENT FACILITIES ARE TO BE OWNED AND MAINTAINED BY A HOME OWNERS ASSOCIATION. TRAFFIC GENERATION AVERAGE DAILY TRIPS FOR SINGLE FAMILY RESIDENTIAL (ITE 210) = 10 ADT WOODLAWN ROAD: 80 ADT (8 SINGLE FAMILY RESIDENTIAL UNITS) PROPO E w 03/25/"2016 VICINITY MAP SCALE: 1" = 21000' OWNER: MARJORIE M.. PAUL 2163 BONAVENTUIRA DRIVE VIENNA, VA 22181 DEVELOPER: WOODLAWN DEVELOPMENT, LLC 2180 OWENSVI LLE RD. CHARLOTTESVILLE, VA 22901 CONTACT: JUSTIN BEIGHTS TELEPHONE: (434) 531-1899 EMAIL: JUSTINBEIGHT;S@C_u .COM ENGINEER OF RECORD: TIMMONS GROUP 919 2ND STREET, S.E. CHARLOTTESVILLE, VA 22902 CONTACT: CRAIG KOTARSKI, PE TELEPHONE: (434) 327-1688 EMAIL: CRAIG.KOTARSKII@T[MMONS.COM Sheet Index Sheet Number Sheet Title C0.0 COVER C1.0 NOTES & DETAILS C2.0 EXISTING CONDITIONS AND DEMOLITION PLAN C3.0 OVERALL LAYOUT PLAN C4.0 EROSION AND SEDIMENT CONTROL NOTES & DETAILS C4.1 EROSION AND SEDIMENT CONTROL NOTES & DETAILS C4.2 EROSION AND SEDIMENT CONTROL PLAN C4.3 EROSION AND SEDIMENT CONTROL PLAN C5.0 SITE LAYOUT C5.1 SITE LAYOUT C6.0 CULVERT PROFILES AND CALCULATIONS C7.0 PRE -DEVELOPMENT DRAINAGE AREA MAP C7.1 POST -DEVELOPMENT DRAINAGE AREA MAP C7.2 STORMWATER MANAGEMENT PLAN DETAILS & CALCULATIONS TOTAL: 14 SHEETS APPROVED by the Albemarle Country Community Development Department Date_ " '` It i�i File E (t1 DATE v 03125116 0 V) O0 C. SHIFFLETT DESIGNED BY c,E C. SHIFFLETT CHECKED BY w "E C. KOTARSKI SCALE N.A. i Q U. N 's C) U_ U,0,>r Q � ° m J z U�0� w� oma; o U :JJ U M z—� U w � vi � W d- a LnN z = Lq O � �– r,4 L H > O� d M w � LLj W W 00 D 0 C.7 j j O O 0 U U z LU LU w ¢ 0 0 z 0 Q f .3 0 o I u) o Q tzt o 0 In 0 !11 2 --i Q cu w w Q H m > o U_ couLU ) 20 0 ® wz U wo o ;� c t6 0 O N _ a o � U J z n o� � x a o 0 o 0 0 0 0 Q� 0 0 2 O) o� > Y �o U O axi o o .E) L � N 0 � L O O U � O W � a U JOB NO. N In ._o @ U 37545 �o SHEET NO. n o CO.0 � E (t1 DATE 03125116 0 DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE N.A. i Q f .3 0 o I u) o Q tzt o 0 In 0 !11 2 --i Q cu w w Q H m > o U_ couLU ) 20 0 ® wz U wo o ;� c t6 0 O N _ a o � U J z n o� � x a o 0 o 0 0 0 0 Q� 0 0 2 O) o� > Y �o U O axi o o .E) L � N 0 � L O O U � O W � a U JOB NO. N In ._o @ U 37545 �o SHEET NO. n o CO.0 � E 14 GENERAL NOTES: 1. ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS. 2. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES. 3. LAND USE PERMITS (LUP-A) MUST BE OBTAINED FROM THE VIRGINIA DEPARTMENT" OF TRANSPORTATION PRIOR TO BEGINNING ANY CONSTRUCTION( WITHIN THE EXISTING STATE MAINTAINED RIGHT OF WAY (INCLUDING ACCESS). 4. VDOT IS TO RECEIVE WRITTEN NOTIFICATION 48 HOURS PRIOR TO COMMENCING WITH INITIAL CONSTRUCTION ACTIVITIES. 5. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC, PRIOR TO CONSTRUCTION. 6. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE OWNER. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE OWNER, BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH CURRENT, 7. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT I AND I LD -94 (D) 121.13. 8. ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN ACCORDANCE WITH ASTM -C-76. PIPE WITHIN THE RIGHT OF WAY SHALL BE MINIMUM CLASS III OR GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS. 9. IF PRE -CAST UNITS ARE TO BE USED, VDOT SHALL BE NOTIFIED AND THE MANUFACTURER SHALL SUBMIT DRAWING DETAILS FOR REVIEW. CEIRTIFICATION AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS. 10. ALL CONCRETE SHALL BE A3 -AE (AIIR ENTRAINED 3,000 PSI), UNLESS OTHERWISE NOTED. 11. ALL ENTRANCES ARE TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CURRENT VDOT STANDARDS. 12. DESIGN CHANGES, SPECIFIED MATEIRIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED AND APPROVED BY THE ENGINEER. 13. CONTRACTOR SHALL VERIFY LOCATI(ON AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAN SHOWN ON PLAN, IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN, CALL MISS UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001, THE OWNER SHALL. BE RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING AND/OR PROPOSED RIGHT-OF-WAY )REQUIRED BY THE DEVELOPMENT. 14. CASING SLEEVES SHALL BE PLACED AT ALL ROAD CROSSINGS FOR GAS, POWER, TELEPHONE AND CABLE TV SERVICE TRUNK LINES. (N/A) 15. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE. 16. VDOT & ALBEMARLE COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY . 17. VDOT SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR INSPECTION FOR THE AtGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 18. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE: YARD (REC-250 PRIME COAT) PER VDOT STANDARDS AND SPECIFICATIONS. 19. THE SCHEDULING OF AGGREGATE BLASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE SPECIFICATIONS. 20. THE OWNERS REPRESENTATIVE SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 21. A GEOTECHNICAL ENGINEER IS TO ASCERTAIN CAUSE AND CERTIFY RECOMMENDED METHOD OF REPAIR FOR ALL PAVEMENT STRUCTURAL FAILURES PRIOR TO STATE ACCEPTANCE. (N/A) 22. ALL VEGETATION AND ORGANIC MATERIAL MATERIAL IS TO BE REMOVED FROM THE PROPOSED PAVEMENT LIMITS PRIOR TO CONDITIONING OF THE SUBGRADE. 23. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO THE OWNER FOR ALL MATERIALS AND BE IN ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICATIONS AND ROAD AND BRIDGE STANDARDS. 24. APPROVAL OF A DETAILED CONSTRUICTION SEQUENCING/MAINTENANCE OF TRAFFIC NARRATIVE FOR THE WORK ZONE IS A PREREQUISITE FOR ISSUANCE OF A LAND USE PERMIT ALLOWING ACCESS TO AND CONSTRUCTION WITHIN VDOT MAINTAINED RIGHT 0)F WAY. (N/A) 25. GRADE LINES ON PROFILES DENOTE (FINISHED GRADE OF CENTER LINE OF ROAD. 26. ALL APPROACH GUTTERS TO SAG INLIETS SHALL MAINTAIN A MINIMUM SLOPE OF 0.004 ft./ft. 27. WHERE A TYPE "B" NOSE IS SPECIFIED ON AN INLET IN CONJUNCTION WITH ROLL FACE CURB AND GUTTER OR CG -7, THERE SHALL BE A 20' TRANSITION ON EACH SIDE OF THE INLET. (N/A) 28. CONTRACTOR SHALL PROVIDE A SEQUENCE OF CONSTRUCTION/MAINTENANCE OF TRAFFIC PLAN IN ACCORDANCE WITH THE STANDARDS AND GUIDELINES CONTAINED IN THE 2011 EDITION OF THE VIRGINIA WORK AREA PROTECTION MANUEL FOR REVIEW BY THE ENGINEER, SCHOOL OFFICIALS, AND VDOT PRIOR TO STARTING WORK THAT IMPACTS TRAFFIC ON STATE ROADS. 29. ALL NEW HANDICAP ACCESSIBLE REQUIREMENTS ON-SITE AND WITHIN ALL NEW STRUCTURES SHALL COMPLY WITH THE 2006 UNIFORM STATEWIDE BUILDING CODE, 2006 VIRGINIA CONSTRUCTION CODE, AND ICC/ANSI Al 17.1-03. 30. THE CLEAR ZONE IS TO BE FREE OF STORED MATERIALS AND PARKED EQUIPMENT. 31. HORIZONTAL AND VERTICAL SIGHT DISTANCES SHALL BE FREE OF PARKED VEHICLES. 32. ALL EXCAVATED AREAS WITHIN THE CLEAR ZONE THAT HAVE A DEPTH GREATER THAN 6" SHALL HAVE A 6:1 STONE WEDGE PLACED AT THE END OF THE DAY 33. SOME LOTS MAY EXPERIENCE WATER, PRESSURE GREATER THAN 80 PSI. ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES: 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT OF WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT. 3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLANT AND MUST BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL: VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. 6. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, I'.T IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 8. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS III. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 (CFR PART 1926). BLASTING NOTES: 1. BLASTING SHALL NOT BE PERMITTED 'ON THIS PROJECT. ALBEMARLE COUNTY STORMWATER MANAGEMENT NOTES: 1. ALL DAMS AND CONSTRUCTED FILL TO BE WITHIN 95% OF MAXIMUM DRY DENSITY AND 2% OF OPTIMUM MOISTURE CONTENT. ALL FILL MATERIAL TO BE APPROVED BY A GEOTECHNICAL ENGINEER. A GEOTECHNICAL ENGINEER IS TO BE PRESENT DURING CONSTRUCTION OF DAMS. 2. PIPE AND RISER JOINTS ARE TO BE WATERTIGHT WITHIN STORMWATER MANAGEMENT FACILITIES. 3. FOR TEMPORARY SEDIMENT TRAPS OR BASINS WHICH ARE TO BE CONVERTED TO PERMANENT STORMWATER MANAGEMENT FACILITIES; CONVERSION IS NOT TO TAKE PLACE UNTIL THE SITE IS STABILIZED, AND PERMISSION HAS BEEN OBTAINED FROM THE COUNTY EROSION CONTROL INSPECTOR. MUTCD STOP SIGN DETAIL No Scale 9 ROAD CROSS SECTION) STARLIGHT VIEW LANE (25 MPH DESIGN SPEED) 40' R/W N STREET PARKING IS NOT PERMITTED C%L 10' (TRAVEL LANE) ') 8%20Y r COMPACTED SUBGRADE - `� 4'M IN. GRASS 4" UNTREATED AGGREGATE SHOULDER NOTE: ROAD CROSS SECTION COMPLIES WITH VDOT SSAR DESIGN STANDARDS. ROAD CROSS SECTION No Scale 1" SM-9.OA _ 10' (TRAVEL LANE) 2' 2%_ 8% _ 2.5" BM-25.OA 4' MIN. GRASS SHOULDER 4'FORESLOPE LEGEND STORM PIPE - - 200 - W_ - EXISTING CONTOUR 200 PROPOSED CONTOUR TC 240.5 PROPOSED SPOT ELEVATION I- DESIGNED BY C. SHIFFLETT CHECKED BY 0 u SCALE N.A. ui cv C:) C3, E Lu (N E CN tj u> u. LL = ®0>r. im, <zw v 00 'J z a J 0 O C'Iw Um H v X <Ivi"t w r a4� �t U) = cn r',J Z z 1q0 �- fq Ln cn rn °' - r' > 4 Lij ww O O 0 0 (D j 00 0 Fr Lu LLJ LuF- � Q z 0 cri DATE 03/25/16 0 DRAWN BY C. SHIFFLETT amO Z, N 70 1� O0 o Olu Q LLI WN Q LLJ >m�� � J o LL o L� O. LU uj :-a 20 " o 0 Qo ® z u o� �o O a.- o cm Z N oa Q � x o- O T 0 Q:F� O O� 0-1) >� �o U N o O U L i N � O N U � O N O U O � C � Q U JOB NO. N o � U 37545 c 2 o v O � U SHEET NO. Q o Cl. 0 v DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE N.A. amO Z, N 70 1� O0 o Olu Q LLI WN Q LLJ >m�� � J o LL o L� O. LU uj :-a 20 " o 0 Qo ® z u o� �o O a.- o cm Z N oa Q � x o- O T 0 Q:F� O O� 0-1) >� �o U N o O U L i N � O N U � O N O U O � C � Q U JOB NO. N o � U 37545 c 2 o v O � U SHEET NO. Q o Cl. 0 v ry L E DATE H 7 0 y 03/25/16 O U) m r DRAWN BY C. SHIFFLETT N CD DESIGNED BY C. SHIFFLETT rn E CHECKED BY C. KOTARSKI ui N E N , SCALE 1 "=60' F LU < U. N 7s LL = ®0'yre < uj "Vz o� O W H C7 U m X cn <pC t1)� W x�N z gL O r N Ln V ) Q� H N 01 d LU re Q' H W W z z O O ZD O > � Z Z O O 0LU a LU Lu , rn = Q 0 0 z O o G < 0 L)J U. 0 0 Q Q ce 0 0 O O N to O N Q U O P-1 ® C N ui F P� Q Q m d 0 Q 0 LL °0 0 a a Ho(L) ::) O od z ]— O }--4 ° z U (Do os 0 u o a )Q ) /� N \J O O m :5R Q Li x �X U LU(D o Q� O§ N (B o U O X O O N U N in C O N U O O N Ea C U cu O a � a� O a U JOB NO. 0 7 [jj� (6 V 37545 �N N O O U SHEET NO. Q o C2.0 ma C,2 .0 (D- F _E DATE H 7 03/25/16 O r DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE 1 "=60' o G < 0 L)J U. 0 0 Q Q ce 0 0 O O N to O N Q U O P-1 ® C N ui F P� Q Q m d 0 Q 0 LL °0 0 a a Ho(L) ::) O od z ]— O }--4 ° z U (Do os 0 u o a )Q ) /� N \J O O m :5R Q Li x �X U LU(D o Q� O§ N (B o U O X O O N U N in C O N U O O N Ea C U cu O a � a� O a U JOB NO. 0 7 [jj� (6 V 37545 �N N O O U SHEET NO. Q o C2.0 ma C,2 .0 (D- F _E E DATE n 03/25/16 d V DRAWN BY C. SHIFFLETT N C ® O E DESIGNED BY C. SHIFFLETT CHECKED BY U1 N LU N C. KOTARSKI SCALE i 1 "=60' ui moi' try U. QLu �r ® iL 0 > r� Uj N (� Q J W J ULuUm Zh'—�t X U W Q.' � LL -W Q U) v) z U) o O _H ,n T C H I- N Ln (f} N } LU m LU Q W W O O O � 2 � O O 0 w LU rn rn < O O Z C:? cn DATE n 03/25/16 O DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY 00 C. KOTARSKI SCALE i 1 "=60' v 0 N O Q O_ T C (6 O N 0 N Q LU 70--� Q co U- Z 2O 0 0 a C7 o m T, z U > s02 0 o T ~ OO -0 O C � O8 O O.O O� Z N O N cc° Q X N O O O N C 7 Y N (q O N U � X N � O U r 2 N 6 o O N U � O N r � U � O � � C co ffi U JOB NO. �° o N 545 "— 7 (B U .3/ N o r. O U SHEET NO. ¢ o (L' -o C3, 0 � � R rr L EROSION AND SEDIMENT CONTROL NARRATIVE: PROJECT DESCRIPTION THIS PROJECT IS A RESIDENTIAL DEVELOPMENT THAT INCLUDES THE ADDITION OF 7 SINGLE FAMILY LOTS AS WELL AS ONE EXISTING SINGLE FAMILY LOT, ALONG WITH ASSOCIATED ROAD, CULVERTS AND STORMWATER MANAGEMENT FACILITIES. LIMITS OF CLEARING AND GRADING ARE 7.94 ACRES, ADJACENT PROPERTY THESE IMPROVEMENTS ARE BEING MADE WITHIN THE PROPERTY BOUNDARY. THE PROPERTY IS BOUNDED BY WOODLANDS ROAD ON THE EAST, AND A RESIDENTIAL PROPERTIES TO THE NORTH, SOUTH, AND WEST, EXISTING SITE CONDITIONS THE SITE IS CURRENTLY A MOSTLY WOODED RESIDENTIAL PROPERTY WITH ONE HOUSE AND ASSOCUATED SITE FEATURES. OFF-SITE AREAS A NEW ENTRANCE ROAD WILL BE CONNECTED TO WOODLANDS ROAD. CRITICAL EROSION AREAS PROPOSED SLOPES STEEPER THAN 3:1 WILL BE STABILIZED WITH BLANKET MATTING. EROSION AND SEDIMENT CONTROL MEASURES UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE CURRENT ADDITION OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. THE MINIMUM STANDARDS OF THE VESCH SHALL BE ADHERED TO UNLESS OTHERWISE VNAIVED OR APPROVED BY A VARIANCE BY LOCAL AUTHORITIES HAVING JURISDICTION. STORMWATER QUALITY CONSIDERATIONS STORMWATER QUALITY REQUIREMENTS ARE BEING MET BY THE USE OF PROPOSED GRASS CHANNELS AND A LEVEL 1 EXTENDED DETENTION FACILITY. STORMWATER RUNOFF CONSIDERATIONS ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED IN ACCORDANCE WITH VESCH AND THE CONSTRUCTION SEQUENCE, INCLUDING THE INSPECTION OF ALL MEASURES AFTER ALL RAIN EVENTS. STRUCTURAL PRACTICES: 1. TEMPORARY CONSTRUCTION ENTRANCE - 3.02 A TEMPORARY CONSTRUCTION ENTRANCE SHALL BE PROVIDED AT THE LOCATION INDICATED ON THE PLANS. IT IS IMPERATIVE THAT THIS MEASURE BE MAINTAINED THROUGHOUT CONSTRUCTION. ITS PURPOSE IS TO REDUCE THE AMOUNT OF MUD TRANSPORTED ONTO PAVED PUBLIC ROADS BY MOTOR VEHICLES OR RUNOFF. 2. SILT FENCE BARRIER - 3.05 SILT FENCE SEDIMENT BARRIERS SHALL BE INSTALLED DOWNSLOPE: OF AREAS WITH MINIMAL GRADES TO FILTER SEDIMENT -LADEN RUNOFF FROM SHEET FLOW AS INDIICATED. ITS PURPOSE IS TO INTERCEPT SMALL AMOUNTS OF SEDIMENT FROM DISTURBED AREAS AND PREEVENT SEDIMENT FROM LEAVING THE SITE. 3. STORM DRAIN INLET PROTECTION - 3.07 STONE FILTERS SHALL BE PLACED AT THE INLET OF ALL DRAINAGE STRUCTURES AS INDICATED ON PLANS. ITS PURPOSE IS TO PREVENT SEDIMENT FROPM ENTERING THE STORM DRAINAGE SYSTEM PRIOR TO PERMANENT STABILIZATION. 4, CULVERT INLET PROTECTION - 3.08 A SEDIMENT FILTER LOCATED AT THE INLET TO A CULVERT T(O PREVENT SEDIMENT FROM ENTERING THE SYSTEM PRIOR TO PERMANENT STABILIZATION. 5, DIVERSION DIKE - 3.09 A TEMPORARY RIDGE OF COMPACTED SOIL TO DIVERT WATER FROM A CERTAIN AREA. 6. SEDIMENT TRAP - 3.13 A TEMPORARY BARRIER OR DAM WITH A CONTROLLED STORMWATER RELEAISE TO DETAIN SEDIMENT -LADEN RUNOFF FROM DISTURBED AREAS IN "WET" AND "DRY" STORAGE LONG EINOUGH FOR THE MAJORITY OF SEDIMENT TO SETTLE OUT. 6.1. MAINTENANCE OF SEDIMENT TRAP - INSPECT TRAP EMBANKMENT WEEKLY TO ENSURE IT IS STRUCTURALLY SOUND AND HAS NOT BEEN DAMAGED DURING CONSTRUCTION ACTIVITIES. ADDITIONALLY THE TRAP SHALL BE CHECKED AFTER EVERY RAINFALL EVENT. ONCE THE SEDIMENT HAS REACHED THE DESIGNATED CLEANOUT LEVEL IT SHALL BE REMOVED AND PROPERLY DISPOSEC) OF, 7. DUST CONTROL - 3.39 DUST CONTROL IS TO BE USED THROUGH THE SITE IN AREAS SUBJECT TOS SURFACE AND AIR MOVEMENT. VEGETATIVE PRACTICES: 8. TOPSOIL (TEMPORARY STOCKPILE) - 3.30 TOPSOIL SHALL BE STRIPPED FROM AREAS TO BE GRADED AND STOCKPILED FOR LATER SPREADING. STOCKPILE LOCATIONS SHALL BE LOCATED ONSITE AND SHALL BE STABILIZED WITH TEMPORARY SILT FENCE AND VEGETATION. 9. TEMPORARY SEEDING - 3.31 ALL DENUDED AREAS WHICH WILL BE LEFT DORMANT FOR MORE TIHAN 30 DAYS SHALL BE SEEDED WITH FAST GERMINATING TEMPORARY VEGETATION IMMEDIATELY FOLLCDWING GRADING OF THOSE AREAS. SELECTION OF THE SEED MIXTURE SHALL DEPEND ON THE TIME OF YEAR IT IS APPLIED. 10. PERMANENT SEEDING - 3.32 FOLLOWING GRADING ACTIVITIES, ESTABLISH PERENNIAL VEGETATIVE COVER BY PLANTING SEED TO REDUCE EROSION, STABILIZE DISTURBED AREAS, AND ENHANCE NATURAL BEAUTY. 11. SOIL STABILIZATION BLANKETS & MATTING - 3.36 A PROTECTIVE COVERING BLANKET OR SOIL STABILIZATION MAT SHALL BE INSTALLED ON PREPARED PLANTING AREAS OF CHANNELS TO PROTECT AND PROMOTE VEGETATION ESTABLISHMENT AND REINFORCE ESTABLISHED TURF. MANAGEMENT STRATEGIES 1, PROVIDE SEDIMENT TRAPPING MEASURES AS A FIRST STEP IN GRADING, SEED AND MULCH IMMEDIATELY FOLLOWING INSTALLATION. 2. PROVIDE TEMPORARY SEEDING OR OTHER STABILIZATION IMMEDIATELY AFTER GRADING. 3. ISOLATE TRENCHING FOR UTILITIES AND DRAINAGE FROM DOWNSTREAM CONVEYANCES IN ORDIER TO MINIMIZE PERIMETER CONTROLS. 4. ALL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE MAINTAINED UNTIL THEY ARE NO LONGER REQUIRED TO COMPLY WITH THE CONTRACT DOCUMENTS OR STATE LAW. PERMANENT STABILIZATION ALL NON -PAVED AREAS DISTURBED BY CONSTRUCTION SHALL BE STABILIZED WITH PERMANENT SEEMING IMMEDIATELY FOLLOWING FINISHED GRADING. SEEDING SHALL BE IN ACCORDANCE WITH STD. & SP?EC. 3.32, PERMANENT SEEDING. SEED TYPE SHALL BE AS SPECIFIED FOR "MINIMUM CARE LAWNS" AND "GENERAL SLOPES" IN THE HANDBOOK FOR SLOPES LESS THAN 3:1. FOR SLOPES GREATER THAN 3:1;, SEED TYPE SHALL BE AS SPECIFIED FOR "LOW MAINTENANCE SLOPES" IN TABLE 3.32-D OF THE HANDBOOK,. FOR MULCH (STRAW OR FIBER) SHALL BE USED ON ALL SEEDED SURFACES. IN ALL SEEDING OPERATIONS; SEED, FERTILIZER AND LIME SHALL BE APPLIED PRIOR TO MULCHING. SEQUENCE OF INSTALLATION 1, A PRE -CONSTRUCTION MEETING IS REQUIRED WITH ALBEMARLE COUNTY E&S INSPECTOR, CONTfRACTOR, OWNER, AND ENGINEER. THIS MEETING SHALL TAKE PLACE AT THE COUNTY OFFICE BUILDING. CLEARING LIMITS MUST BE FLAGGED PRIOR TO THE MEETING WITH ONE (1) WEEK OF NOTICE. 2, INSTALL CONSTRUCTION ENTRANCE. 3. INSTALL PERIMETER SILT FENCE AND TREE PROTECTION FENCING. 4. CLEAR AND GRADE AREA FOR SEDIMENT BASIN 1 AND INSTALL. 5. INSTALL DIVERSION DIKE, AND REMAINING SILT FENCE, 6. ONCE SEDIMENT BASIN 1 AND THE PERIMETER CONTROL MEASURES ARE IN PLACE, CONSTRUCTION ON WOODLAWN ROAD MAY BEGIN. 7, ROUGH GRADE PROJECT AREA. 8, INSTALL WOODLAWN ROAD, AND CULVERTS A AND B, INSTALL CULVERT INLET AND OUTLET PROTECTION. 9. ONCE UPSLOPE AREAS ARE PERMANENTLY STABILIZED, AND WITH THE COUNTY INSPECTOR APPROVAL, REMOVE CULVERT INLET PROTECTION, DEWATER SEDIMENT BASIN 1, REMOVE SATURATED SEDIMIIENT BASIN MATERIAL, AND CONVERT TO SWM -1, LEVEL 1 EXTENDED DETENTION FACILITY, REMOVE REMAINING EROSION AND SEDIMENT CONTROL MEASURES. 10. FINALIZE GRASS CHANNEL GRADING AND GROUNDCOVER ONLY AFTER CONTRIBUTING DRAINAGE- AREA IS STABILIZED. 11. SEED ALL DENUDED AREAS PER VESCH STANDARDS. MINIMUM STANDARDS: GENERAL CONSTRUCTION NOTES FOR EROSION AND SEDIMENT CONTROL: AN EROSION AND SEDIMENT CONTROL PROGRAM ADOPTED BY A DISTRICT OR LOCALITY MUST BE 1. THE PLAN APPROVING AUTHORITY MUST BE NOTIFIED ONE WEEK PRIOR TO THE PRE -CONSTRUCTION CONSISTENT WITH THE FOLLOWING CRITERIA, TECHNIQUES AND METHODS: 0 V CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE MS -1. PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIIN SCALE WEEK PRIOR TO THE FINAL INSPECTION. SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL 2. ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CONSTRUCTED AND MAINTAINED STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMEN-T AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT a, E CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN REGULATIONS. ONE YEAR. 3. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE FIRST STEP MS -2. DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES AND BORROW AREAS SHALL BE IN CLEARING, STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE SITIE RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL AT ALL TIMES. STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE THE PROJECT SITE. PLANS (INCLUDING, BUT NOT LIMITED TO, OFF-SITE BORROW OR WASTE AREAS), THE CONTRACTOR MS -3. A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE SHALL SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND PERMANENTLY STABILIZED, PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED APPROVAL BY THE PLAN APPROVING AUTHORITY. UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL WILL INHIBIT EROSION. MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE PLAN MS -4. SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES Lu 0 APPROVING AUTHORITY. INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES LAND -DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND Lu ¢ _j tco z DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION DISTURBANCE TAKES PLACE. IS ACHIEVED. MS -5. STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES 8. DURING DEWATERING OPERATIONS, WATER WILL BE PUMPED INTO AN APPROVED FILTERING DEVICE. AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 9. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH MS -6. SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP OR BASIN. OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. A. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE 10. ALL FILL MATERIAL TO BE TAKEN FROM AN APPROVED, DESIGNATED BORROW AREA. OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE 11. ALL WASTE MATERIALS SHALL BE TAKEN TO AN APPROVED WASTE AREA. EARTH FILL SHALL BE INERT ACRES. r- X u MATERIALS ONLY, FREE OF ROOTS, STUMPS, WOOD, RUBBISH, AND OTHER DEBRIS. B. SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE 12, BORROW OR WASTE AREAS ARE TO BE RECLAIMED WITHIN 7 DAYS OF COMPLETION PER ZONING AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASRN. c ice u ORDINANCE SECTION 5.1.28. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134 CUBIC YARDS PER ACRE: 13. ALL INERT MATERIALS SHALL BE TRANSPORTED IN COMPLIANCE WITH SECTION 13-301 OF THE CODE OF OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL ALBEMARLE. INTEGRITY OF THE BASIN DURING A 25 -YEAR STORM OF 24-HOUR DURATION. RUNOFF 14. BORROW, FILL OR WASTE ACTIVITY INVOLVING INDUSTRIAL -TYPE POWER EQUIPMENT SHALL BE COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL CORRESPOND TO A BARE EARTH m��" z LIMITED TO THE HOURS OF 7:OOAM TO 9:OOPM. CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS 15. BORROW, FILL OR WASTE ACTIVITY SHALL BE CONDUCTED IN A SAFE MANNER THAT MAINTAINS UTILIZED. Lq 0 LATERAL SUPPORT, OR ORDER TO MINIMIZE ANY HAZARD TO PERSONS, PHYSICAL DAMAGE TO MS -7. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL ADJACENT LAND AND STRUCTURES/IMPROVEMENTS, AND DAMAGE TO ANY PUBLIC STREET BECAUSE OF MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR N Ln ccn SLIDES, SINKING, OR COLLAPSE, OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING 16, THE DEVELOPER SHALL RESERVE THE RIGHT TO INSTALL, MAINTAIN, REMOVE OR CONVERT TO MEASURES UNTIL THE PROBLEM IS CORRECTED. PERMANENT STORMWATER MANAGEMENT FACILITIES WHERE APPLICABLE ALL EROSION CONTROL MS -8. CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED MEASURES REQUIRED BY THIS PLAN REGARDLESS OF THE SALE OF ANY LOT, UNIT, BUILDING OR OTHER WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN � ML/ PORTION OF THE PROPERTY. STRUCTURE. 17, TEMPORARY STABILIZATION SHALL BE TEMPORARY SEEDING AND MULCHING, SEEDING IS TO BE AT 75 MS -9. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION LBS/ACRE, AND IN THE MONTHS OF SEPTEMBER TO FEBRUARY TO CONSIST A 50/50 MIX OF ANNUAL SHALL BE PROVIDED. RYEGRASS AND CEREAL WINTER RYE, OR IN MARCH AND APRIL TO CONSIST OF ANNUAL RYE, OR MAY MS -10. ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE Lu THROUGH AUGUST TO CONSIST OF GERMAN MILLET. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. PROTECTED SO THAT SEDIMENT -LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR, WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 18. PERMANENT STABILIZATION SHALL BE LIME AND FERTILIZER, PERMANENT SEEDING, AND MULCH. MS -11. BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE AGRICULTURAL GRADE LIMESTONE SHALL BE APPLIED AT 90LBS/1000SF, INCORPORATED INTO THE TOP OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENTF 4-6 INCHES OF SOIL. FERTILIZER SHALL BE APPLIED AT 1000LBS/ACRE AND CONSIST OF A 10-20-10 CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING NUTRIENT MIX. PERMANENT SEEDING SHALL BE APPLIED AT 180LBS/ACRE AND CONSIST OF 95% CHANNEL. KENTUCKY 31 OR TALL FESCUE AND 0-5% PERENNIAL RYEGRASS OR KENTUCKY BLUE -GRASS. STRAW MS -12. WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO EROSION CONTROL INSPECTOR. THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE 19, MAINTENANCE: ALL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL EVENT. ANY USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED vi DAMAGE OR CLOGGING TO STRUCTURAL MEASURES SHALL BE REPAIRED IMMEDIATELY, SILT TRAPS FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. SHALL BE CLEANED WHEN 50% OF THE WET STORAGE VOLUME IS FILLED WITH SEDIMENT. ALL SEEDED MS -13. WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE � AREAS SHALL BE RESEEDED WHEN NECESSARY TO ACHIEVE A GOOD STAND OF GRASS, SILT FENCE AND IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF DIVERSION DYKES WHICH COLLECT SEDIMENT TO HALF THEIR HEIGHT MUST BE CLEANED AND NONERODIBLE MATERIAL SHALL BE PROVIDED. 0 REPAIRED IMMEDIATELY. MS -14. ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS PERTAINING TO WORKING IN OR 20. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS OF CROSSING LIVE WATERCOURSES SHALL BE MET, FINAL SITE STABILIZATION, WHEN MEASURES ARE NO LONGER NEEDED, SUBJECT TO APPROVAL BY THE MS -15. THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN COUNTY EROSION CONTROL INSPECTOR. THE WATERCOURSE IS COMPLETED. 21. THIS PLAN SHALL BE VOID IF THE OWNER DOES NOT OBTAIN A PERMIT WTIHIN 1 YEAR OF THE DATE OF MS -16, UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING APPROVAL. (WATER PROTECTION ORDINANCE SECTION 17-204G.) STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: 22. PERMANENT VEGETATION SHALL BE INSTALLED ON ALL DENUDED AREAS WITHIN NINE (9) MONTHS A. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. AFTER THE DATE THE LAND DISTURBING ACTIVITY COMMENCED. (WATER PROTECTION ORDINANCE B. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. SECTION 17-2078) C. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY, D. MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. E. RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. F. APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH, MS -17. WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, Q PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR w w rn PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING ANDS TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWE'ED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER, THIS PROVISION SHALL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND -DISTURBING ACTIVITIES. MS -18. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE LOCAL PROGRAM AUTHORITY. TRAPPED z SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARIY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND 0 SEDIMENTATION. MS -19. PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE STANDARDS AND CRITERIA LISTED IN SECTION 19 OF THE VIRGINIA ADMINISTRATIVE CODE 9VAC25-840-40 MINIMUM STANDARDS. GENERAL EROSION AND SEDIMENT CONTROL NOTES: ES -1: UNLESS OTHERWISE INDICATED, CONSTRUCT AND MAINTAIN ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL PRACTICES ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE LATEST EDITION OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS, ES -2: THE CONTROLLING EROSION AND SEDIMENT CONTROL AUTHORITY WILL MAKE A CONTINUING REVIEW AND EVALUATION OF THE METHODS AND EFFECTIVENESS OF THE EROSION CONTROL PLAN, ES -3: PLACE ALL EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO OR AS THE FIRST STEP IN CLEARING, GRADING, OR LAND DISTURBANCE. ES -4: MAINTAIN A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN ON THE SITIE AT ALL TIMES. ES -5: PRIOR TO COMMENCING LAND -DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFFSITE BORROW OR WASTE AREA), SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE ARCHITECT/ENGINEER AND THE CONTROLLING EROSION AND SEDIMENT CONTROL AUTHORITY FOR REVIEW AND ACCEPTANCE. ES -6: PROVIDE ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE RESPONSIBLE LAND DISTURBER. (MODIFIED NOTE) ES -7: ALL DISTURBED AREAS SHALL DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND -DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT. ES -8: DURING DEWATERING OPERATIONS, PUMP WATER INTO AN APPROVED FILTERING DEVICE. ES -9: INSPECT ALL EROSION CONTROL MEASURES DAILY AND AFTER EACH RUNOFF- PRODUCING RAINFALL EVENT. MAKE ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES IMMEDIATELY. ww #. L ic- No. 0-10,20118507 7 I s E DESIGNED BY C. SHIFFLETT CHECKED BY 0 V C. KOTARSKI SCALE 1"=30` U) N 0 ® o a, E Lu cv E N , r- F u > yS LL Lu 0 Lu ¢ _j tco z w., (D uj U m; r- X u c ice u m��" z Lq 0 N Ln ccn � ML/ Lu ww O 0 vi � U U 0 X: z z O 0 Q w w rn rn o z 0 V) DATE 03/25/16 0 D RAW N BY C. SHIFFLETT am N U 0 CL C o o 2- Lf u o 0 0Q > Lu 0J m ! m O < 0 � c� 0 ® �o a�--i o E �o W �c 0 � U 66 o= o o z N o0 :�v 1... i g x t--� °' U) o 0 0 o 00 L N (p N U x O O U s� v n �a N U � a Ei3 U � O - 0 -O E- N � 70 U � JOB NO. o 0 N - m U 37545 c2 �o � U SHEET NO. Q o C4.0 DESIGNED BY C. SHIFFLETT CHECKED BY 00 C. KOTARSKI SCALE 1"=30` am N U 0 CL C o o 2- Lf u o 0 0Q > Lu 0J m ! m O < 0 � c� 0 ® �o a�--i o E �o W �c 0 � U 66 o= o o z N o0 :�v 1... i g x t--� °' U) o 0 0 o 00 L N (p N U x O O U s� v n �a N U � a Ei3 U � O - 0 -O E- N � 70 U � JOB NO. o 0 N - m U 37545 c2 �o � U SHEET NO. Q o C4.0 .............. .......... .............. Table 15: Sediment Basin design (spec 3.14) ti # 's s • � s ..... ........ .._... ..... .._.... ........ ....... ,..... ..... MIN, I'M SP#LL'. - Y 2",MTHOU'T CREST OF DAMANcf SF'tCUS'.kY drainage area (acres) 11.36 ..... DESIGN H10 WATER � f 03/25/16 basin volumes (using 2' contour internals) „ I..i,..,., ,:3" MIN. (JL5 -YR, MRM FXV,) (LOLIUM (MULTI-FLORUM) TEMPORARY SEEDING PLANT MATERIALS elevation (ft) ..c..._ontour area (s..f.). .... volume c --" - - J. SHOWALTER CEREAL (WINTER) RYE 2850 ......... 530 8930 4363 s _u52.5 _.__ N$s R CREST __. ...... X32 10660 .. _ ........ 725.6 " DRY"' S71C3r2�.GE �- -.: -.•-- Cit ti.YiEiYI Nt3 NICE ..... 534 12550 859.6 ° WET ' STfO Aar CARE LAWN } 536 14230 ....._ .............. ........ ....... ......... 991.9 .. .....,.... �x 175-200 LBS. 5.1 i 'ON SHALLOW SLOPES, STRIPS NETTING ........ ............... ............_.... ...........- ........ .............. SE£rtMEtJLE Ck.£AICU?" P014T ✓"J (" WON! $VAACc RE3UCEu ... B-B ....... .. .........----.-. ........ ........._. ................. ................. ...._......_._ ..... TV ,'-•44 C.Y,aACI{F,) IMPROVED PERENNIAL RYEGRASS 0-5% Wet storage .. ..... ..... . 0-5% ..... ... Wet storage required (cy) (67*DA) ......... ...._.... 761.1 Ides€gn high water 535-0 dewatering orifice elevation (ft) ......... 531.0 Itop of darn (fit) OVER THE BERM AND ANCHOR IT BEHIND THE BERM. 536.0 Diet storage provided at this elevation (cy) 798.5" .... ltop width of dam (ft) RED TOP GRASS 8.0 available v`o ume before cleanout (cy) 399.3 lbottom of basin (ft) 20 LBS. 529.5 ......... ._..... cleanout elevation (ft) ... 5300 ........ +approx. bottom dimensions ..... 140x80' distance frc�rn cleanout to orifice (ft) (> 1') 1 0:: lupstream face slope' k6 101 KENTUCKY 31 FESCUE .............................. ... ............................................. idgwnstream face slope- 3:1 RED TOP GRASS * .... .... dry storage: U LEVEL AREA BEFORE SEASONAL NURSE CROP 20 LBS. dry storage required (cy) (67 BA) 761.1 lbaffles no ........ __ ......... ......... `principle spillway crest (ft)...... ...... 5332 liength of flow, L (ft) DITCH` 140. `dry storage provided at this elevation (Cy) ._ 951.0 ....... ........ leffective Width, We (ft) ,FLOW 80 ..... - ............. diameter of dewateringorifice (€n) _......._..._.. 3.0 ......... IL / We (baffles required if > 2) STATED BELOW: 1-8: ........ ..............._ ......._..._ _... ..... ..---.... ,............. diameter of flexible tubing (in) (orifice+2") ......................... 6.0' .. _....._ ANNUALRYE .._.......... ...... _ _ ....... _ ................... +collars: n€� AS REQUIRED. AVOID JOINING MATERIAL IN ........ runoff z . ........ ....... . idepth of Water at spillway crest (ft) ... ............. 4.7 C (use 0.45 for bare earth) 0.45 Slope of upstream face (Z 1 } ........................ '3 tc (min) ... 20 . ;slope of barrel (Sb) 2-78 ... . 12yi 2.8 0 2yr ...... . ......... 14.3 liength of barrel in saturated zone (Ls)...... ......... ...... ... 60 125yt 4 3 0 25yr . 22.0 ... (number collars required ..... .............. 2 ......... sdirnension of collars 5x5 . principle spillway ......... ... ......... .. ....... ....: ...... ...... ....... ....... ..... available head (ft) .. .... ..... ......... ............... 1.8' +emergency spillway. ......... ....... ....:.... yes ... ........ ....... __ diameter nser (in) ... ... ........ ...... ....... 48 (required capacity (Q25-Qp) (cfs);; N/A ....................... spillway capacity, Qp (cfs) 75.0 (bottom width (ft) 16 diameter trash racy (in) 72 ;slope of exist channel (ft/ft) 0.1 head on barrel through embankment (ft) 5.5 ,crest of spillway (ft) 53�_? diameter of barrel (in) 24'; ........ ....... Riser crest elevation and dry storage determined by extended detnetion facility SWM -1 design SB -1 SEDIMENT BASIN #1 No Scale SPACING BETWEEN CHECK DAMS AND B ARE OF EQUAL ELEVATION 0 91 11MR--kikkkil 10 • i' a � ; ><:Z••ia•._. ...!i An. _.•i.•::� �._..J �L����i���r Vii. 3do PIPE OUTLET CONDITIONS A A SECTION A -A do La 0% FILTER CLOTH CREST ELEV. 533.20 DRY STORAGE DEWATERING DEVICE 6" PERFORATED PVC 3" ORIFICE WET STORAGEEW-1 PLUG 3" ORIFICE (FOR SWM -1) SWM -1 BOTTOM 529.50 8' DIIA. X 1.5' CONC. BASE 6'- 6" PVC, @ 1.7% IPE OUTLET TO FLAT AREA /ITH NO DEFINED CHANNEL KEY IN 6"-9"; RECOMMENDED FOR ENTIRE PERIMETER La 0% 3do(MIN.) IPE OUTLET TO WELL EFINED CHANNEL SECTION A -A FILTER KEY IN 6"-9"; RECOMMENDED FOR CLOTH ENTIRE PERIMETER NOTES: 1. APRON LINING MAY BE RIPRAP, GROUTED RIPRAP, GABION BASKET, OR CONCRETE. 2. La IS THE LENGTH OF THE RIPRAP APRON AS CALCULATED USING PLATES 3.18-3 AND 3.18-4. 3. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER, BUT NOT LESS THAN 6 INCHES. NO SCALE TREE PROTECTION TOP OF DAM = 536.00 10'SAFETY 8' BENCH 48" RCP RISER W/ ANTI -VORTEX DEVICE INV IN 529.40 (6" PVC) INV OUT 529.30 (24" HDPE) 90.00'- 24" HDPE @ 2.78% 16'GRASS SPILLWAY ELEV. 534.20 IMPERVIOUS CORE AND CUTOFF TRENCH NOTES:RIP-RAP OUTLET - 1. IMPERVIOUS CORE AND CUTOFF TRENCH SHOWN FOR PROTECTION INFORMATIONAL PURPOSES ONLY. FINAL DESIGN TO BE PROVIDED BY GEOTECHNICAL ENGINEER. 2. REFER TO SHEET C7.2 FOR FINAL DESIGN OF SWM -1 2 X 4" WOOD SILT FENCE DROP INLET PROTECTION FRAME TABLE 3.31-BMAX.ACCEPTABLE TEMPORARY SEEDING PLANT MATERIALS "QUICK REFEREINCE FOR ALL REGIONS" PLANTING DATES SPECIES RATE (LBS./ACRE DRAINS A RELATIVELY FLAT AREA (SLOPE NO GREATER THAN 5%) WHERE > SEPT. 1 - FEB. 15 50/150 MIX OF THE INLET SHEET OR OVERLAND FLOWS (NOT EXCEEDING 1 C.F.S.) ARE TYPICAL. THE METHOD SHALL NOT APPLY TO INLETS RECEIVINGCONCENTRATED 03/25/16 ANNUAL RYEGRASS „ I..i,..,., ,:3" MIN. FLOWS, SUCH AS IN STREET OR HIGHWAY MEDIANS. (LOLIUM (MULTI-FLORUM) TEMPORARY SEEDING PLANT MATERIALS FILTER CLOTHSECTION A -A & 50-10 J. SHOWALTER CEREAL (WINTER) RYE DESIGNED BY (SECALE CEREALE) 6'-7" FEB. 16 - APR. 30 ANNUAL RYEGRASS 60-1 CHECKED BY (LOLIUM MULTI-FLORUM) Lu N N :,_, MAY 1 - AUG. 31 GERMAN MILLET (SETARIA ITALICA) 70' MIN. 5:1 EXISTING 3 PAVEMENT FILTER 6' M MOUNTABLE BERM A CLOTH (OPTIONAL) EXISTING GROUND SIDE ELEVATION I 70' MIN. [ WASHRACK0' MIN. EI( (OPTIONAL)JIN B I EXISTING 12' MIN. i;€II; " PAVEMENT E ....._ .,I . VDOT #1 COARSE AGGREGATE B POSITIVE'MIN.DRAINAGE TFic € MUST EXTEND FULL WIDTH OF SEDIMENT I INGRESS AND EGRESS OPERATION TRAPPING DEVICE DROP INLET WITH GRATE FRAME STONE CONSTRUCTION ENTRANCE No Scale �nanonn-rcn call 0 r�r�Jr«. t s v� vILYYJ I No Scale STAKM )IN FABRIC -y li 1. SET THE STAKES. 2. EXCAVATE A 4"X 4" TRENCH UPSLOPE ALONG THE LINE OF STAKES.7.7 JMIN. 6' 50 ; ;`DETAIL AFLOW '' / r' ELEVATION OF STAKE AND FABRIC ORIENTATION �4SPECIFIC APPLICATION 3. STAPLE FILTER MATERIAL TO STAKES AND 4. BACKFILL AND COMPACT THE THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE THE INLET EXTEND IT INTO THE TRENCH. EXCAVATED SOIL. U0 -._3" DRAINS A RELATIVELY FLAT AREA (SLOPE NO GREATER THAN 5%) WHERE > MIN. THE INLET SHEET OR OVERLAND FLOWS (NOT EXCEEDING 1 C.F.S.) ARE TYPICAL. THE METHOD SHALL NOT APPLY TO INLETS RECEIVINGCONCENTRATED 03/25/16 „ I..i,..,., ,:3" MIN. FLOWS, SUCH AS IN STREET OR HIGHWAY MEDIANS. ES -1 TEMPORARY SEEDING PLANT MATERIALS FILTER CLOTHSECTION A -A INIV 526.80 J. SHOWALTER No Scale DESIGNED BY No Scle 6'-7" C. KOTARSKI TYPICAL ORIENTATION OF TREATMENT - 1 SOIL (STABILIZATION BLANKET) SITE SPECIFIC SEEDING MIXTURES FOR PIEDMONT AREASHALLOWTOTAL CHECKED BY Lu N N :,_, C. KOTARSKI LBS. PER ACRESLOPEMINIMUM CARE LAWN } - ' (`F,COMMERCIAL OR RESIDENTIAL 175-200 LBS. 5.1 i 'ON SHALLOW SLOPES, STRIPS NETTING REINFORCED CONCRETE DRAIN SPACESECTION ''PROTECTIVE COVERINGS MAY BE B-B 90-100% DROP INLET WITH GRATE FRAME STONE CONSTRUCTION ENTRANCE No Scale �nanonn-rcn call 0 r�r�Jr«. t s v� vILYYJ I No Scale STAKM )IN FABRIC -y li 1. SET THE STAKES. 2. EXCAVATE A 4"X 4" TRENCH UPSLOPE ALONG THE LINE OF STAKES.7.7 JMIN. 6' 50 ; ;`DETAIL AFLOW '' / r' ELEVATION OF STAKE AND FABRIC ORIENTATION �4SPECIFIC APPLICATION 3. STAPLE FILTER MATERIAL TO STAKES AND 4. BACKFILL AND COMPACT THE THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE THE INLET EXTEND IT INTO THE TRENCH. EXCAVATED SOIL. SUBSTITUTE SERICEA LESPEDEZA FOR CROWNVETCH EAST OF FARMVILLE, VA (MAY THROUGH SEPTEMBER USE HULLED SERICEA, ALL OTHER PERIODS, USE UNHULLED SERICEA), IF FLATPEA IS USED IN LIEU OF CROWNVETCH, INCREASE RATE TO 30 LBS./ACRE. ALL LEGUME SEED MUST BE PROPERLY INOCULATED. WEEPING LOVEGRASS MAY BE ADDED TO ANY SLOPE OR LOW -MAINTENANCE MIX DURING WARMER SEEDING PERIODS; ADD 10-20 LBS./ACRE IN MIXES. PERMANENT SEEDING MIX FOR PIEDMONT AREA OUTLET PROTECTION No Scale No Scale 1l � !� 1 I-�STANDARD ORANGE VINYL OR PLASTIC CONSTRUCTION FENCE ATTACHED TO POSTS (PRE -WEATHERED WOOD, GALVANIZED STEEL, IRON OR THICK PVC PLASTIC), AT LEAST 40" ABOVE FINISH GRADE WITH SPAN BETWEEN POSTS NO GREATER THAN 6'ON CENTER. EVERY NINTH POST SHALL CONTAIN A WARNING SIGN THAT CLEARLY IDENTIFIES THE FENCE AS A TREE PROTECTION FENCE. SOIL STABILIZATION BLANKET (EC - 2) No Scale SILT FENCE CULVERT INLET PROTECTIION LFLOW DISTANCE IS 6'MINIMUM IF FLOW IS TOWARD EMBANKMENT "OPTIONAL STONE COMIBINATION 1.0' 1.5' ni FEew _ 2.5' **VDOT #3, #357, #5, #56 OR #57 CLASS I COARSE AGGREGATE TO REPLACE SILT RIPRAP FENCE IN " HORSESHOE " WHEN HIGH 3.38 CSP VELOCITY OF FLOW IS EXPECTEDC3,08-1 CULVERT INLET PROTECTION No Scale FLC SHEET FLOW INSTALLATION (PERSPECTIVE VIEW) POINTS A SHOULD BE HIGHER THAN POINT B. SF DRAINAGEWAY INSTALLATION 3.05-2 (FRONT ELEVATION) SILT FENCE (W/O WIRE SUPPORT) No Scale C 7 / I I i PROFILE �101N;TPI i MSF+, , 2% 2% x IVU {1I I' , P-, .L= ddI ti I F lit Irk i, €:+- 21 SS k PLAN i I %' MIN, i I I- II rr iRf Iti .tF Iii :: II s_•.ir WYIk IF+IIC", F Ii_Tr� ca_c-rl l SECTION A A A minim m tit atet tai) of 1 ilial iuu'4 be iTi; tr111ed With a TuhliT>ium 1 ilich b0cocic slrtTtTiiT <at. e ugptyiTa a' inti hose with a diameter oft, ~ inches tiler acteeluate Constant pre."Ilre. 'txv ilsl, wa(er anus>t be c:aniechTti m! flow the eutx uw.e to an at�pro�°etl ;~ettliTT�,� at e� to Tema;ie ;�eduueitt. _�E1 secliTuent i,lrall be pret�eriteci ii ck�tl e>rteiinw' Manu draim, ciitk,iie€; or ��'tlterc+nTTr;eS. �4 y fi k II� ��� I1 ♦ � ��� iMr ani I` iVf iI�I pNtl i E U0 DATE DRAINS A RELATIVELY FLAT AREA (SLOPE NO GREATER THAN 5%) WHERE > THE INLET SHEET OR OVERLAND FLOWS (NOT EXCEEDING 1 C.F.S.) ARE TYPICAL. THE METHOD SHALL NOT APPLY TO INLETS RECEIVINGCONCENTRATED 03/25/16 FLOWS, SUCH AS IN STREET OR HIGHWAY MEDIANS. TEMPORARY SEEDING PLANT MATERIALS N � STORM DRAIN INLET PROTECTION J. SHOWALTER No Scale DESIGNED BY No Scle TABLE 3.32-D C. KOTARSKI TYPICAL ORIENTATION OF TREATMENT - 1 SOIL (STABILIZATION BLANKET) SITE SPECIFIC SEEDING MIXTURES FOR PIEDMONT AREASHALLOWTOTAL CHECKED BY Lu N N :,_, C. KOTARSKI LBS. PER ACRESLOPEMINIMUM CARE LAWN } - ' (`F,COMMERCIAL OR RESIDENTIAL 175-200 LBS. 5.1 i 'ON SHALLOW SLOPES, STRIPS NETTING N ''PROTECTIVE COVERINGS MAY BE KENTUCKY 31 OR TURF -TYPE TALL FESCUE 90-100% """` APPLIED ACROSS THE SLOPE. IMPROVED PERENNIAL RYEGRASS 0-5% KENTUCKY BLUEGRASS 0-5% ,L - WHERE THERE IS A BERM AT THE TPBERM OF THE SLOPE, BRING THE MATERIALGENERAL SLOPE (3:1 OR LESSi) LU 0 STEEP OVER THE BERM AND ANCHOR IT BEHIND THE BERM. KENTUCKY 31 FESCUE 128 LBS. SLOPE RED TOP GRASS 2 LBS. SEASONAL NURSE CROP * 20 LBS. ON STEEP SLOPES, APPLY PROTECTIVE O 150 LBS.,` Y COVERING PARALLEL TO THE DIRECTION LOW -MAINTENANCE SLOPE (STEEPER THAN 3:1) k6 r :rOF FLOW AND ANCHOR SECURELY. KENTUCKY 31 FESCUE 108 LBS. BRING MATERIAL DOWN TO A RED TOP GRASS * 2 LBS. U LEVEL AREA BEFORE SEASONAL NURSE CROP 20 LBS. TERMINATING THE4INSTALLATION. CROWNVETCH *'` 20 LBS. TURN THE END 2„ 150 LBS. DITCH` UNDER 4" AND STAPLE AT 12" W ,FLOW USE SEASONAL NURSE CROP IN ACCORDANCE WITH SEEDING DATESfAS 0 STATED BELOW: r•' : �;.. IN DITCHES, APPLY PROTECTIVE COVERING FEBRUARY 16TH THROUGH APRIL ................ ... ...............IFMAY ANNUALRYE - ` °t PARALLEL TO THE DIRECTiION OF FLOW. USE CHECK 1ST THROUGH AUGUST 15TH ............................ FOXTAIL MILLETSLOTS AS REQUIRED. AVOID JOINING MATERIAL IN cnxv"" z THE CENTER OF THE DITCH IF AT ALL POSSIBLE. AUGUST 16TH THROUGH OCTOBER ............................... NOVEMBER THROUGH FEBRUARY 15TH ANNUAL RYE WINTER RYE U� I- N Ln ........................ SUBSTITUTE SERICEA LESPEDEZA FOR CROWNVETCH EAST OF FARMVILLE, VA (MAY THROUGH SEPTEMBER USE HULLED SERICEA, ALL OTHER PERIODS, USE UNHULLED SERICEA), IF FLATPEA IS USED IN LIEU OF CROWNVETCH, INCREASE RATE TO 30 LBS./ACRE. ALL LEGUME SEED MUST BE PROPERLY INOCULATED. WEEPING LOVEGRASS MAY BE ADDED TO ANY SLOPE OR LOW -MAINTENANCE MIX DURING WARMER SEEDING PERIODS; ADD 10-20 LBS./ACRE IN MIXES. PERMANENT SEEDING MIX FOR PIEDMONT AREA OUTLET PROTECTION No Scale No Scale 1l � !� 1 I-�STANDARD ORANGE VINYL OR PLASTIC CONSTRUCTION FENCE ATTACHED TO POSTS (PRE -WEATHERED WOOD, GALVANIZED STEEL, IRON OR THICK PVC PLASTIC), AT LEAST 40" ABOVE FINISH GRADE WITH SPAN BETWEEN POSTS NO GREATER THAN 6'ON CENTER. EVERY NINTH POST SHALL CONTAIN A WARNING SIGN THAT CLEARLY IDENTIFIES THE FENCE AS A TREE PROTECTION FENCE. SOIL STABILIZATION BLANKET (EC - 2) No Scale SILT FENCE CULVERT INLET PROTECTIION LFLOW DISTANCE IS 6'MINIMUM IF FLOW IS TOWARD EMBANKMENT "OPTIONAL STONE COMIBINATION 1.0' 1.5' ni FEew _ 2.5' **VDOT #3, #357, #5, #56 OR #57 CLASS I COARSE AGGREGATE TO REPLACE SILT RIPRAP FENCE IN " HORSESHOE " WHEN HIGH 3.38 CSP VELOCITY OF FLOW IS EXPECTEDC3,08-1 CULVERT INLET PROTECTION No Scale FLC SHEET FLOW INSTALLATION (PERSPECTIVE VIEW) POINTS A SHOULD BE HIGHER THAN POINT B. SF DRAINAGEWAY INSTALLATION 3.05-2 (FRONT ELEVATION) SILT FENCE (W/O WIRE SUPPORT) No Scale C 7 / I I i PROFILE �101N;TPI i MSF+, , 2% 2% x IVU {1I I' , P-, .L= ddI ti I F lit Irk i, €:+- 21 SS k PLAN i I %' MIN, i I I- II rr iRf Iti .tF Iii :: II s_•.ir WYIk IF+IIC", F Ii_Tr� ca_c-rl l SECTION A A A minim m tit atet tai) of 1 ilial iuu'4 be iTi; tr111ed With a TuhliT>ium 1 ilich b0cocic slrtTtTiiT <at. e ugptyiTa a' inti hose with a diameter oft, ~ inches tiler acteeluate Constant pre."Ilre. 'txv ilsl, wa(er anus>t be c:aniechTti m! flow the eutx uw.e to an at�pro�°etl ;~ettliTT�,� at e� to Tema;ie ;�eduueitt. _�E1 secliTuent i,lrall be pret�eriteci ii ck�tl e>rteiinw' Manu draim, ciitk,iie€; or ��'tlterc+nTTr;eS. �4 y fi k II� ��� I1 ♦ � ��� iMr ani I` iVf iI�I pNtl i E U0 DATE > 0 v 03/25/16 N � J. SHOWALTER DESIGNED BY O E C. KOTARSKI CHECKED BY Lu N N :,_, C. KOTARSKI SCALE } N ¢ �. v ,L - LU 0 Q w " Cc z Q > O k6 (D LU Ut U Lj X <IY � W 0 oa r cnxv"" z U� I- N Ln rn �' > w m tY �i- LU ww O O Ui vv � O � z z O Q) h - LU LU LU LLJ = Q o am 2 _ P ­q N 3 U I- O o Ca r),. 06 0 Q LU � o ON N Om Q Q 0 Uj N (Y LU Q m o IC LjILL 0o s W �o z -0[)� LU E0 U so » o� Q E_ �o �v -0 660 z N O Q 5�x o Q)0 0 o Q� Oo� Q LU �� �N U � �o U U E EN o U � o E o -a c JOB NO. 0 o 37545 c N N C U SHEET NO. Q o C4.1W LD F U0 DATE > 03/25/16 DRAWN BY J. SHOWALTER DESIGNED BY C. KOTARSKI CHECKED BY C. KOTARSKI SCALE AS SHOWN am 2 _ P ­q N 3 U I- O o Ca r),. 06 0 Q LU � o ON N Om Q Q 0 Uj N (Y LU Q m o IC LjILL 0o s W �o z -0[)� LU E0 U so » o� Q E_ �o �v -0 660 z N O Q 5�x o Q)0 0 o Q� Oo� Q LU �� �N U � �o U U E EN o U � o E o -a c JOB NO. 0 o 37545 c N N C U SHEET NO. Q o C4.1W LD F E (!) DATE O V 03/25/16 0 V) N � 0 6 DRAWN BY C. SHIFFLETT E DESIGNED BY C. SHIFFLETT LU N E CHECKED BY C. KOTARSKI LU 1- u > 'S SCALE 1 "=40` Q LL N 3: LL Lu0> n < -j W M 00 71 a L N fa 0 W U M — 1— W �2! i LL- W L Q V) z -0Ln 0 2 r r -i N m LLJ M � d' u-, W U) OO U ::DU 0 = Z Z � O O 0 U U F- 0 0 w �10 w Q O Q N O O N 0 a 3 z Q J d U Ly N d' U L0 N O N O Cn Q O (T W ry o C cu O O M M O Jo Z c U C N N O N O Q C 0 O 1 N N N Q S > C) O 1�r'7 C LLuL N ry cu P-1 < ui ui U UJ Q Q LLJ O � 2O �r � 2 o 0 m Z U�o o � c - �o m � �.1 C a o 00 � U C Cn LUz N o� �Q X N O } 0 � O 2 w A N C } N (B (D .0 U O � O N U 2 h cu cO y7 U O O N O O U � O "O O O Q U JOB NO. N .- o N 37545� U l0n w O O U SHEET NO, Q o N � C4.2 JzF- (!) DATE 03/25/16 0 DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI i SCALE 1 "=40` Z c U C N N O N O Q C 0 O 1 N N N Q S > C) O 1�r'7 C LLuL N ry cu P-1 < ui ui U UJ Q Q LLJ O � 2O �r � 2 o 0 m Z U�o o � c - �o m � �.1 C a o 00 � U C Cn LUz N o� �Q X N O } 0 � O 2 w A N C } N (B (D .0 U O � O N U 2 h cu cO y7 U O O N O O U � O "O O O Q U JOB NO. N .- o N 37545� U l0n w O O U SHEET NO, Q o N � C4.2 JzF- V Lic. No, f)44,1204 850", gry 7119J IG �4 ag gi "�CWAL lllala-� -' Ln 0 -1: 0 uj u O U) 0 DATE 03125116 DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE •1 "=401 < icL O OS Z ry 7. rn 0 O < 2: > 0 LL� U 70 cl� <1 >f ;7 U.iLU cc < U- 0 Lu co Z) Z) C(D L 0 2 z (v 0 U < �� 2 02 lz -6 0 CU 0 L) 0 0 Z ui 0 4 Li 46 0 0 C3 2 O Ea 70 (D .6-0 30B NO. .2 37545 70. SHEET NO. C4.3 C s C cn DATE H O V 03/25/16 O N N 0 DRAWN BY C. SHIFFLETT ®O c, E DESIGNED BY C. SHIFFLETT W N N CHECKED BY C. KOTARSKI LU SCALE 1 "=40` Q 0 Lu O > r - Q �v M00 Z W o �; O L H N C7 LU U c Zu S O w SC (n g < U— w U) = cn z =�vG,n O N vi H N m CL/ W W O O ® t I OO O O LU LU W W S Q < O O z O N a s U C O N O t N O Q Q T O 'O 0 N to N 1 �l i O l 7 / C / L Lq L. N 6 D H <t 0 > m <2 O O N O Lua o �- ._ 0 IL LU 20 70� 0 ry�� Q o '...J 2 Z U 2 � o � c — E H `° o c � c a o � U O� Z N O(l) 2E Q 0 :E X N O O O 0 O 0-0) N C Y N {� U N X O O U L 2 � y t9 O N U C LO O E 6 U O -O.S U JOB NO. o 0 U) - � U 37545 0 N �o � U SHEET NO. Q o w-0 C5, 0 0 F-- cn DATE H 03/25/16 O DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE 1 "=40` 0 a s U C O N O t N O Q Q T O 'O 0 N to N 1 �l i O l 7 / C / L Lq L. N 6 D H <t 0 > m <2 O O N O Lua o �- ._ 0 IL LU 20 70� 0 ry�� Q o '...J 2 Z U 2 � o � c — E H `° o c � c a o � U O� Z N O(l) 2E Q 0 :E X N O O O 0 O 0-0) N C Y N {� U N X O O U L 2 � y t9 O N U C LO O E 6 U O -O.S U JOB NO. o 0 U) - � U 37545 0 N �o � U SHEET NO. Q o w-0 C5, 0 0 F-- DRAINAGE AREA TO CULVERT B I DITCH A = 4.770 AC C= 0.44 TC= 20 MIN 1(2)= 2.8 IN/HR Q(2) = 0.44(4.77)(2.8) = 5.88 CFS 1(10) = 4.0 IN/HR Q(10) = 0.44(4.77)(4.0) = 8.40 CFS V(2) = 4.41 FT/S (ALLOWABLE VELOCITY = 5 FT/S) D(10) = 0.76' GRASS LINED DITCH n=0.035;S=5% DITCH A - ROAD SIDE SCC C� ...... I Xxx r : .rte. a... .... ........... .....:o.,. o, E I (� DATE O U 03/25/16 O N = CD o DRAWN BY C. SHIFFLETT m E DESIGNED BY C. SHIFFLETT W N E Lu N CHECKED BY C. KOTARSKI 11J Q SCALE 1 "=40` ® LL Lu ® 7 I� ¢'x' " z J00 LufaH o O L Iti (D Lu U m 01 U 0, W Q u') <Ca ti W 04+;� U) x cn C z = a Lq O i- N U-)ccn �rn H N > Lu Lu � ti W W vi O O U U O = Z � O O O c� z n �D ',D ui L'i H R < o Q) z O _ 0 0 _ Q _ o70 N O N i O N Ld ce Z C F---1 w Q L LU 30 Q0 ® z �0 �o � o � U Q � cq 0 N N A 2i X H O N O N � O cy A � N C � Y N (B � N U X C 0,0 N w U i N � O � O O B`a z U O - -0 O -0 _C N a - II U JOB NO. o 0 cu U 37545 0 N � O O U SHEET NO. 0-2 m � C5.1 r - (� DATE 03/25/16 O DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE 1 "=40` _ 0 0 _ Q _ o70 N O N i O N Ld ce Z C F---1 w Q L LU 30 Q0 ® z �0 �o � o � U Q � cq 0 N N A 2i X H O N O N � O cy A � N C � Y N (B � N U X C 0,0 N w U i N � O � O O B`a z U O - -0 O -0 _C N a - II U JOB NO. o 0 cu U 37545 0 N � O O U SHEET NO. 0-2 m � C5.1 r - 14 0 m10 0 10 20 30 40 50 60 Station Uj LU (Y > > w LLl > U U U U 00 0 ® �� o 580 o `no " r- r80 560 o f9 c�i 560 + LD LUn0 U) /� r �..I vJ T Q 0-> </� L > W 'r^ ._0 O LL LU V! L7 > Z z W U Z Lu Z U 575 575 555 555 Q LU OF- Z LU SHOULDER ELEVATION = 570.50-----_______U Q SHOULDER ELEVATION = 548.38 0 O O 570" 570 550 3: 550 PROPOSED GRADE EX P 565 _._565 545 545 ___- d-- -:.-_-_-----------------___..._._.____... 3 OP 560_..__ S4F._...._..... .T 560 540 S3 _ 540 EXISTI jG GRADE 1 555 555 535 535 550 550 530 530 9+50 10+00 11+00 CULVERT A HORIZ SCALE: 1 "=40' VERT SCALE: 1 "=4 HY-8 Analysis Results Culvert Summary Table - 18" HDPE Culvert Crossing: Culvert A Discha Tota! Culvert Headw Inlet Out{ett Flow 25 -YR FREEBOARD: SHOULDER ELEV. - Hvv -> 570.50 - 566.13 = 4.37' Grassing - CulvertA, Design Discharge - 4.2 cfs Calvert - 18" HDPE, Calvert Discharge - 4.2 cfs Critical ......:........................._ Normal Pr0fi1 Tailwater Headwater Strearnbed ».:.. 570 r 569_ ... 567... f% i n w 566 ;,a y ED 565 564M € is 563 w 562 s: "s. 561..,;.,, ..;;%� ..::.✓"�...�`" :,,; {_ ,,,.,.i ',. „�..-.;; vi' ....,.. .y ii';..,,k,,,,,.,�M��,.>:G�:1.a:3uum,.,.c<:,,.,.<6, .wJ:3;. i., �:z i ,ti,,,�✓.�::2�,c�,,;�.;ii�,�,:5r�iiS%. -20 -10 0 10 20 30 40 0 60 70 o 90 Station (ft) HY-8 Analysis Results Normal Critical Outlet Tailwat Outlet Tailwat rge Discha Discha after Control Control Type Depth Depth Depth er Velocity er Names rge rge Elevati (ft) (ft) (fit) Depth (ftfs) Velocity (cfs} (cfs} on (ft) Depth(f Depth(f f) {ft) (ft/s) 10 year 3.53 3.53 566.01 1.01 O.d* 1-S2n 0.36 0.72 0.44 0.34 8.13 3.37 25 year .23 4.23 566.13 1.13 0.0* 1-S2n 0.39 0.79 0.50 0.38 8.28 3.55 DRAINAGE AREA TO CULVERT A = 2.26 AC C= 0.39 TC= 20 MIN I(10) = 4.0 IN/HR Q(10) = 0.39(2.26)(4.0) = 3.53 CFS 1(25) = 4.8 IN/HR Q(25) = 0.39(2.26)(4.8) = 4.23 CFS CULVERT A CALCULATION No Scale 9+50 10+00 11+00 CULVERT B HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 B Discha Total Culverrt Headw Inlet outlet Flow Normal Critical Outlet Tailwat Outlet Tailwat rge Discha Discha ater Control Control Type Depth Depth Depth er Velocity er Names rge rge Elevati (ft) (ft) (ft) Depth {ft/s} Velocity (cfs) (cfs) on (ft) Depth(f Depth(f (ft) (ft/s) t) Ebl5tll 10 year 8.40 8.40 546.47 1.87 n 0.58 1.12 0.74 0.54 9.64 4.30 25 year 10.07 10.07 J546,8512.25 n 0.64 1.22 d.83 10-59 ISTING GRADE ROPOSED GRADE Culvert Summary Tante - 18" HDPE Culvert Crossing: Culvert 25 -YR FREEBOARD: SHOULDER ELEV. - Hw -> 548.38 - 546.85 = 1.53' _._. Culvert - 18" BDPa, Calvert Discharge - 10, l e£s y - Cdtical Normal Profile T"aiYrater Headwater Stream 548 547 5 0 50 PROFILE SCALE 5ed 543 MR (ft) DRAINAGE AREA TO GULVER;T B = 4.770 AC C= 0.44 TC= 20 MIN I(10 = 4.0 IN/HR Q(10) = 0.44(4.77)(4.0) = 8.40 CFS I(25) = 4.8 IN/HR Q(25) = 0.44(4.77)(4.8) = 10.07 CFS CULVERT !B CALCULATION _ c, ..Y . 2°.,f 10.49 .52 25 -YR FREEBOARD: SHOULDER ELEV. - Hw -> 548.38 - 546.85 = 1.53' _._. Culvert - 18" BDPa, Calvert Discharge - 10, l e£s y - Cdtical Normal Profile T"aiYrater Headwater Stream 548 547 5 0 50 PROFILE SCALE 5ed 543 MR (ft) DRAINAGE AREA TO GULVER;T B = 4.770 AC C= 0.44 TC= 20 MIN I(10 = 4.0 IN/HR Q(10) = 0.44(4.77)(4.0) = 8.40 CFS I(25) = 4.8 IN/HR Q(25) = 0.44(4.77)(4.8) = 10.07 CFS CULVERT !B CALCULATION _ c, ..Y . 2°.,f O 0 r� DATE 03/25/16 DRAWN 8Y C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE AS SHOWN Lf)Q U C tv O0 N O Q I- o O Lz 016 LU UQ s Q LL 2 Lii�il N � z � �o a � o � Q LE E 2 Z g� c a� a � a o D U Z N O N � X O F N O O O o � Q � N � > '1 N (>S � N �o O U L � o N U cz O Q1 E � U � o- �a Q U JOB NO. � o 375 45 U SHEET NO. Q o � O O Z O O 0 r� DATE 03/25/16 DRAWN 8Y C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE AS SHOWN Lf)Q U C tv O0 N O Q I- o O Lz 016 LU UQ s Q LL 2 Lii�il N � z � �o a � o � Q LE E 2 Z g� c a� a � a o D U Z N O N � X O F N O O O o � Q � N � > '1 N (>S � N �o O U L � o N U cz O Q1 E � U � o- �a Q U JOB NO. � o 375 45 U SHEET NO. Q o w I L ARM A 7 00 10 m SCALE 1"=60' 'ME 0 60, 120' . c .4 'U ip �A- CIQ�, Lic, No� (04 020d 85 011 71191 �r it" m E DATE O 03125116 C:,c C. SHIFFLETT DESIGNED BY Q, E C. SHIFFLETT CHECKED BY Lu " E m r\l C. KOTARSKI SCALE ji F- Lu < L. Q LL 0 LU < _j co a- ;� LU 0 lay > U UJ U I- —'T C� 0 Lj X u <cn < -1 ui LL ui 0� Q� Q C) -T U) 0 L9 N V) ui m 0') m LU � LU C) 0 F- r) LU U.j rn Q Z: o 0 0 -�n r) CL < '0') LU LZ 7." < 0 < > LLJ o ULL� ) —i < cro cu < > LU < ry < Qo) LL 0 Ake% Q LLJ 70 >- :3 "o o 0:D z 0 L(l) 1 2 U Ljj -j so :�E 0 2E c > T'6 E'6 CL =) o U 0 < 0 Q) X Q) r) I 0 Q) (D 0--l- 2 0 X (D 2 0 E O 7(-) _o. Q) JOB NO. o -- m �o 2 37545 c - w o SHEET NO. w-0 2 C7. 0 wQ) - DATE 03125116 DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE ji 1 "=60' o 0 0 -�n r) CL < '0') LU LZ 7." < 0 < > LLJ o ULL� ) —i < cro cu < > LU < ry < Qo) LL 0 Ake% Q LLJ 70 >- :3 "o o 0:D z 0 L(l) 1 2 U Ljj -j so :�E 0 2E c > T'6 E'6 CL =) o U 0 < 0 Q) X Q) r) I 0 Q) (D 0--l- 2 0 X (D 2 0 E O 7(-) _o. Q) JOB NO. o -- m �o 2 37545 c - w o SHEET NO. w-0 2 C7. 0 wQ) - Q) Wo .Y" F l y q r ) 1 t7{ N 04 i' 'y i a j�'�bt � F � � �' •€ '4�'�' H �.ry i ME L- SCALE 1"=60' 0 60' 120' E v vi N CD o cT, E W cv E ry }, I— L.1 < Q U. ® U. _ W 0 '> rn Q LV � M a- -100 LU 21,ri O ry ,> In W Q - LL- 0Q+� d U*) r14 i V2 rq Ln rd � LU Ln,/ 6�L 0 U 0 D w Lu U 0 M 0 z O_ ry U cn LU 0 O IHI^^ Vl W ry DATE 03/25/16 DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE 1 "=60` JOB NO. 37,54.5 SHEET NO. C7.1 24" LONG EPDXY C 24" TW ELEV. 531.00 GABION BASKET FOREBAY WALL No Scale WATER QUANTITY ANALYSIS GENERAL NOTES FOR TRASH RACK (TYP.) X 1 1/2" X TEEL ANGLE LB PER FT2 NDED STEEL E BASED ON FLOW OPENING HOLES HOWN (TYP.) 1/2" X 1/4" LE (TYP.) /4" STEEL _DED TO OAJL AJ JHOWN 1, STEEL TO CONFORM TO ASTM A-36. 2. ALL SURFACES OF TRASH RACK(S) MUST BE HOT DIPPED GALVANIZED AFTER FABRICATION. 3. TRASH RACK(S) TO BE FASTENED TO WALL WITH 1/2" MASONRY ANCHORS. TRASH RACK(S) TO BE REMOVABLE. 4. TRASH RACK(S) TO BE CENTERED HORIZONTALLY OVER THE OPENING. 5. FABRICATOR MAY MODIFY COMPONENTS OF TRASH RACK FRAME TO IMPROVE CONSTRUCTABILITY OF TRASH RACK. MODIFICATIONS MUST BE APPROVED BY MCDPS PRIOR TO FABRICATION. ORIFICE TRASH RACK DETAIL DETAIL TAKEN FROM MONTGOMERY COIUNTY, MD WATER RESOURCES SPECIFICATIONS 1.12' FREEBOARD 100 -YR ELEV. 534.88 CREST ELEV. 533.20 TOP OF DAM = 536.00 10' SAFETY 8' BENCH 16' GRASS SPILLWAY ELEV. 534.20 IMPERVIOUS CORE AND CUTOFF TRENCH 1 -YR ELEV = 532.31 2 -YR ELEV = 533.30 10 -YR ELEV = 533.89 100 -YR ELEV = 534.88 PLUG 3" ORIFICE N FROM SB -1 48" RCP RISER W/ ANTI -VORTEX DEVICE INV IN 529.40 (6" PVC) INV OUT 529.30 (24" HDPE) EW -1 f' 3" ORIFICE W/ TRASHRACK 529.50 fir` 90.00'- 24" HDPE @ Z78% POND BOTTOM 529.50 ,f ; 6'-6"PVC@1.7% 8'DIA.X1.5' CONC.BASE s .............. :..........................,.,...............---.._......................�......��.....-7-........................... m.._m.__.�..�... , EMBED 6" IN CONCRETE NOTES: 1. TRASH RACK TO BE INSTALLED ON 3" ORIFICE AS SHOWN ON RIP -RAP OUTLET DETAIL ON THIS SHEET OR APPROVED EQUAL. PROTECTION 2. IMPERVIOUS CORE AND CUTOFF TRENCH SHOWN FOR INFORMATIONAL PURPOSES ONLY. FINAL DESIGN TO BE PROVIDED BY GEOTECHNICAL ENGINEER. QUALITY CALCULATIONS: Tv = 13,147 CU. FT. VOLUME PROVIDED AT RISER CREST (533.20) = 17,395 CU. FT. 24 -HR DRAW DOWN ORIFICE SIZING CALCULATION: SWM -1 - EXTENDED DETENTION FACILITY DETAIL (LEVEL ONE No Scale n = 0.20 2'1 7' Slope = 1.5% 1.33' l•T f \"-GRASS CHANNEL QUALITY CALCULATIONS: (PER SPECIFICATION NO. 3, VERSION 1.9.) DRAINAGE AREA TO GRASS CHANNEL A = 2.750 AC 1" RUNOFF CALCULATION PER VSMH 11.5.3 AS REFERENCED IN SPECIFICATION 3, VERSION 2.0, PAGE 12.: 1. CN CALCULATION: CN = 1000 [10+ 5(1 In) + 10Qa - 10(Qa2+ 1.250a )1.5 ] Qa = Tv / Drainage Area -> [2582 Cf / (2.75 Ac X 43,560 Sq Ft)] X 12 In. = 0.259 In CN = 1000 [10+ 5(1 In) + 10(0.259) - 10((0.259) + 1.25(0.259))0.5 ] CN=88 2. Tc: 24.2 MINUTES (REFER TO CALC BOOK) 3. 1" RAINFALL WATER QUALITY FLOW RATE, gpTv la= 0.273 (FROM TR -55 TABLE, BASED ON CN = 88) gpTv = q,, X A X Qa (q,, from Exhibt 4 -IA in TR -55; A in Square Miles) gpTv = 72 X 0.0043 Mi X 0.259 = 0.08 CFS CHANNEL DESIGN: MAXIMUM DEPTH FOR THE Tv PEAK FLOW (1" RAINFALL) = 3" DEPTH PROVIDED = 0.84" MINIMUM HYDRAULIC RESIDENCY TIME = 9 MINUTES HYDRAULIC RESIDENCY TIME PROVIDED = L / V(1") / (60 S/MIN) 125'1 (0.15 FT/S) / 60 = 13.89 MINUTES GRASS CHANNEL A CALCULATIONS No Scale WATER QUANTITY IS ADDRESSED BY THE USE OF A PROPOSED EXTENDED DETENTION SWM FACILITY. THE FACILITY IS DESIGNED TO DETAIN AND RELEASE STORMWATER AT AN APPROPRIATE RATE FOR THE 1, 2, AND 10 YEAR DESIGN STORM EVENTS. THE EMERGENCY SPILLWAY IS DESIGNED SUCH THAT A MINIMUM OF V FREEBOARD IS MAINTAINED. 1 -YEAR STORM EVENT CALCULATIONS: ENERGY BALANCE EQUATION: MAX. 01(1YR POST -DEV) = 0.8[Q(1YR PRE -DEV)X(Rv(lYR PRE -DEV] 1 Rv(1YR POST -DEV) FROM HYDROGRAPHS WITHIN CALCULATIONS BOOK: Q(1YRfPRE) = 6.23 CFS; RUNOFF VOLUME (Rv) = 0.974 AC -FTX 43,560 = 42,427 CF Rv(1YR POST) = POST DEV. #1A + POST DEV. #1 B + POST DEV. #1 + POST DEV. #1 U = 4,274 CF + 9,428 CF + 11,491 CF + 19,639 CF = 44,832 CF = 0.8(6.23 CFS X 42,427 CU.FT.) / 44,832 CU.FT = 4.72 CFS POST D)EVELOPED Q(1) = 2.80 CFS 2 AND 10 -YEAR STORM EVENT SUMMARY: Q(2) PR;E-DEV = 14.65 CFS Q(2) POST -DEV = 7.18 CFS Q(10) PIRE-DEV = 47.46 CFS Q(10) POST -DEV = 46.24 CFS Qavg = 13,147 CU.FT. / (24hr)(3,600 s/hr) = 0.152 CFS Qmax = 2(Qavg) = 0.304 CFS REQUIRED ORIFICE AREA = 0.304 CFS / 0.6 (64.4)(h) = 0.033 SQ.FT. -> DIAMETER = 2.46" ORIFICE DIAMETER PROVIDED: 3" (MINIMUM RECOMMENDED) EROSION/ CAPACITY CALCULATIONS: DRAINAGE AREA TO GRASS CHANNEL A = 2.75 AC Q(2 -YR) = 1.64 CFS Q(10 -YR) = 4.83 CFS MAXIMUM Q(2 -YR) VELOCITY = 5 FT/S Q(2 -YR) VELOCITY PROVIDED = 0.45 FT/S Q(10 -YR) CAPACITY: MINIMUM FREEBOARD = 0.5' D(10 -YR): 0.76' CHANNEL DEPTH: 1.33' FREEBOARD PROVIDED = 0.57' WATER OUALITY ANALYSIS SITE DATA POST DEVELOPED SITE AREA: 23.01 ACRES IMPERVIOUS = 1.77 ACRES MANAGED TURF = 18.04 ACRE WOODS = 3.20 ACRE TOTAL LOAD REDUCTION REQUIRED (LB/YR) = 2.86 LB/YR ON SITE TREATMENT PROPOSED GRASS CHANNELS A 8, B AND EXTENDED DETENTION LEVEL ONE: TOTAL PHOSPHOROUS LOAD REDUCTION ACHIEVED (LB/YR) = 2.86 LB/YR n = 0.035 (-2'1 Slope = 1.5% 24' -j GRASS CHANNEL QUALITY CALCULATIONS: (PER SPECIFICATION NO. 3, VERSION 1.9.) DRAINAGE AREA TO GRASS CHANNEL A = 5.179 AC 1" RUNOFF CALCULATION PER VSMH 11.5.3 AS REFERENCED IN SPECIFICATION 3, VERSION 2.0, PAGE 12.: 1. CN CALCULATION: CN = 1000 [10+ 5(1 In) + 10Qa - 10(Qa2-+ 1.25Qa)0.5 ] - Qa = Tv / Drainage Area -> [5984 Cf / (5.1£8 Ac X 43,560 Sq Ft)] X 12 In. = 0.318 In CN = 1000 [10+ 5(1 In) + 10(0.318) - 10(;(0.318) '+1.25(0.318)) 0. 1.25(0.318))0.5 ] CN = 90 2. TO: 26.1 MINUTES (REFER TO CALC BOOK) 3. 1" RAINFALL WATER QUALITY FLOW RATE, gpTv la= 0.222 (FROM TR -55 TABLE, BASED ON CN = 88) gpTv = qU X A X Qa (qu from Exhibt 4 -IA in TR -55; PN in Square Miles) gpTv = 95 X 0.008 Mi X 0.318 = 0.242 CFS CHANNEL DESIGN: MAXIMUM DEPTH FOR THE Tv PEAK FLOW (1" RAINFAILL) = 3" DEPTH PROVIDIED = 1.08" MINIMUM HYDRAULIC RESIDENCY TIME = 9 MINUTES HYDRAULIC RESIDENCY TIME PROVIDED = L / V(1") / ((60 S/MIN) 115'/ (0.11 FT/S) / 60 = 17.42 MINUTES GRASS CHANNEL B CALCULATIONS No Scale Cel: EROSION / CAPACITY CALCULATIONS: ES -1 INV 526.80 DRAINAGE AREA TO GRASS CHANNEL A = 5.179 AC Q(2 -YR) = 3.50 CFS Q(1 0 -YR) = 9.57 CFS MAXIMUM Q(2 -YR) VELOCITY = 5 FT/S Q(2 -YR) VELOCITY PROVIDED = 0.29 FT/S Q(10 -YR) CAPACITY: MINIMUM FREEBOARD = 0.5' D(10 -YR): 0.83' CHANNEL DEPTH: 1.33' FREEBOARD PROVIDED = 0.5' LEVEL SPREADER DETAIL No Scale 12" v _TD. CLASS Al RIPRAP, E N C CD rn E CV E LU ry +, i- J-4 > Q LL N 3: LL LU 0 ul 1-1 ¢ UJ M a- 1 UJ O a U) UUJ UM 2,_ _ ct x cl ifL 0 d �t Ln cV F- r4 Ln O) rn ';1' LU z O 0- U 00 w Z O U) W ri DATE 03/25/16 DRAWN BY C. SHIFFLETT DESIGNED BY C. SHIFFLETT CHECKED BY C. KOTARSKI SCALE 1 "=40' o 0 7 N < U 0 � iu Q) r � 0 `.J N m < "`,a ym o n Q 0 U o N 0� Q) Q > o WUj C� Q `° w < co jLj 0 U_ I-- l.Li 0 0o o� 8- OLU U 0 -20 < ��_ T f- <_ ao � V Q o= ® LU z� ,- o Qx F(D o w 0 D N U Qw o� 0 ID_> F N cz 0 y v= �o �E �N o N U � O N __ U � 0 va Ma .- U JOB NO. 0 o " .- � U 3/7 545 002 _ �o = U SHEET NO. - o C7.2