Loading...
HomeMy WebLinkAboutARB201800032 Staff Report 2018-03-26ARCHITECTURAL REVIEW BOARD STAFF REPORT Project #/Name ARB-2018-32: Royal Fern Townhomes, Initial Site Plan Review Type Initial Site Development Plan Parcel Identification 07600000005400 Location North of 5th Street (Route 631/Old Lynchburg Road), east of Old Lynchburg Road, and west of Wahoo Way Zoned R10 Residential (R10), Entrance Corridor (EC) Owner/Applicant Gambit LLC & Snow Paws LLC, et. al./Landstriker LLC & Shimp Engineering (Justin Shimp) Magisterial District Scottsville Proposal To construct 30 single-family attached units on 3.43 acres. Context The site lies immediately west of the Cavalier Crossing development, on the north side of Old Lynchburg Road. The area is characterized by a mix of single-family detached dwellings and multi -family residential development; the County's 51 Street Office Building lies to the south and the Region Ten facility lies adjacent to the north. The northernmost point of the triangular site lies approximately 680 feet south of the southern edge of the 1-64 right-of- way while the eastern property line lies approximately 2,250 feet west of the 1-64 interchange with 5th Street [Figure 1]. The parcel is wooded while a knoll on the eastern edge of the property line is fill from previous development at Cavalier Crossing. Managed slopes lie along the southern property line, adjacent to the EC [Figure 2]. The southern edge of the parcel varies from 4 to 20 feet north of the north side of 5t' Street. Visibility When the site is cleared for development, the majority of the townhouses will be readily visible from the EC. Two buildings of 7 units each are proposed parallel to the EC, while another building containing 6 units proposed on the northeast side will be visible via Wahoo Way. The remaining 10 units divided between two buildings positioned on the northwest property line and at the northern apex of the triangular site are not expected to be visible from the EC. ARB Meeting Date April 2, 2018 Staff Contact Heather N. McMahon Figure]: the subject parcel (TMP 76-54) lies behveen Old Lynchburg Road, Wahoo Way, and 5'Street/Route 631. Figure 2: the subject parcel ('1'MP 76-54) has significant grade changes and managed slopes, especially along the EC frontage/southern property boundary. PROJECT HISTORY The ARB has not reviewed cases pertaining to this undeveloped parcel previously, although the ARB has reviewed several projects relating to the neighboring parcel to the east, the residential development now called Cavalier Crossing. DATE APPLICATION REVIEW TYPE RESULT 6/18/1997 ZMA-1996-24 Application to rezone TMPs 76-54, 76-54A, 76-5513, and 76-55D (approximately 43 acres) from R-2 to R-15 Request denied; BOS approved rezoning the parcels from R-2 to R-10 4/2/18 ARB-2018-32 Royal Fern Townhomes Initial Site Development Plan This is the first time the ARB will review this project ANALYSIS Gray highlight = means the guideline can't be reviewed at initial site plan stage, but recommendations can be provided for final Yellow highlight = means the guideline can only be reviewed for location/configuration at the initial plan stage Regular text = means the guideline can be reviewed at initial plan stage, can be made a condition of initial plan approval, and can be the basis for denial REF GUIDELINE ISSUE RECOMMENDATION GENERAL GUIDELINES Purpose 1 The goal of the regulation of the design of development No architectural elevations, plans or material Submit architectural plans, within the designated Entrance Corridors is to insure that new samples have been submitted for review. elevations, and material development within the corridors reflects the traditional The site plan proposes 30, three-story (45- samples for review with the architecture of the area. Therefore, it is the purpose of ARB feet tall) townhouse units divided among 5 final site plan. review and of these Guidelines, that proposed development buildings: 2 buildings containing 7 units within the designated Entrance Corridors reflect elements of each lie on the southern property line, design characteristic of the significant historical landmarks, adjacent to the EC; 2 buildings containing 6 buildings, and structures of the Charlottesville and Albemarle units and 3 units lie on the northeast area, and to promote orderly and attractive development property line; and 1 building containing 7 within these corridors. Applicants should note that replication units lies on the northwest property line. of historic structures is neither required nor desired. [Figure 3] The fagades of the 14 units adjacent to the EC will be visible, as will 4 2 Visitors to the significant historical sites in the Charlottesville and Albemarle area experience these sites as ensembles of side elevations of the end units. Similarly, buildings, land, and vegetation. In order to accomplish the the southernmost 6 units on the northeast integration of buildings, land, and vegetation characteristic of property line will be visible via Wahoo Way. these sites, the Guidelines require attention to four primary The 3 units at the northernmost apex of the factors: compatibility with significant historic sites in the triangular site and the building containing 7 area; the character of the Entrance Corridor; site development units on the northwestern property line are and layout; and landscaping. not expected to be visible from the EC. Figure 3: proposed site plan for the subject parcel (TW 76-54), Initial Site Development Plan for Royal Fern Townhomes, Albemarle County, Virginia, (C3: Site Plan), drawn by Shimp Engineering, P.C., 2120118 4 Compatibility with significant historic sites: 3 New structures and substantial additions to existing structures No architectural elevations, plans or material See recommendation in #1. should respect the traditions of the architecture of historically samples have been submitted for review. significant buildings in the Charlottesville and Albemarle area. Photographs of historic buildings in the area, as well as drawings of architectural features, which provide important examples of this tradition are contained in Appendix A. 4 The examples contained in Appendix A should be used as a guide for building design: the standard of compatibility with the area's historic structures is not intended to impose a rigid design solution for new development. Replication of the design of the important historic sites in the area is neither intended nor desired. The Guideline's standard of compatibility can be met through building scale, materials, and forms which may be embodied in architecture which is contemporary as well as traditional. The Guidelines allow individuality in design to accommodate varying tastes as well as special functional requirements. Compatibility with the character of the Entrance Corridor 5 It is also an important objective of the Guidelines to establish The character of this portion of the EC is See recommendation in # 1. a pattern of compatible architectural characteristics largely residential, with a mix of single - throughout the Entrance Corridor in order to achieve unity family detached homes and multi -family and coherence. Building designs should demonstrate residential development, although the sensitivity to other nearby structures within the Entrance Region Ten facility lies northwest of the Corridor. Where a designated corridor is substantially parcel and the County Office Building lies developed, these Guidelines require striking a careful balance directly across 5t' Street, to the south. The between harmonizing new development with the existing development of this block is entirely character of the corridor and achieving compatibility with the residential and is in keeping with this significant historic sites in the area. parcel's zoning. Site development and layout 6 Site development should be sensitive to the existing natural The site plan is configured to fit within the None. landscape and should contribute to the creation of an triangular -shaped parcel [see Figure 3]. 5 organized development plan. This may be accomplished, to buildings are oriented around a central, the extent practical, by preserving the trees and rolling terrain triangular open space encompassing 6,129 typical of the area; planting new trees along streets and square feet; a private street (Road A) and a pedestrian ways and choosing species that reflect native private alley circumscribe the open space. forest elements; insuring that any grading will blend into the The rear elevations are oriented to the surrounding topography thereby creating a continuous interior of the site. landscape; preserving, to the extent practical, existing The topography of the site is drastically significant river and stream valleys which may be located on undulating, with managed slopes within the the site and integrating these features into the design of site, predominantly on the southern property surrounding development; and limiting the building mass and line (closest to the EC) [Figure 4]. Extensive height to a scale that does not overpower the natural settings grading will be necessary to create building of the site, or the Entrance Corridor. sites. While this guideline recommends "preserving the ... rolling terrain" to the extent practical, the dramatic character of this site would preclude any development without significant grading and fill. Still, grading could be accomplished that "insures any grading will blend into the surrounding topography thereby creating a continuous landscape." Only those trees in the southwestern corner (dog -leg) of the parcel are proposed to be retained; the rest will be cleared for development. Figure 4: panoramic view of the subject parcel (TMP 76-54), showing grade differentiation across site. Photo taken by Heather McMahon 3115118. Landscaping 7 The requirements of the Guidelines regarding landscaping are The proposed landscaping is limited to Provide a landscape plan that intended to reflect the landscaping characteristic of many of street trees along the EC and Wahoo Way. addresses all EC landscape the area's significant historic sites which is characterized by guidelines, complete with large shade trees and lawns. Landscaping should promote plant schedule, for review with visual order within the Entrance Corridor and help to the final site plan. integrate buildings into the existing environment of the corridor. 8 Continuity within the Entrance Corridor should be obtained by planting different types of plant materials that share similar characteristics. Such common elements allow for more flexibility in the design of structures because common landscape features will help to harmonize the appearance of development as seen from the street upon which the Corridor is centered. Compatibility with significant historic sites 9-16 Structure design No architectural elevations, plans or See recommendation in #1. material samples have been submitted for review. The fagades of the 14 units adjacent to the EC will be visible, as will 4 side elevations of the end units. Similarly, the southernmost 6 units on the northeast property line will be visible via Wahoo Way. Therefore, the designs of these side elevations should have sufficient detailing to meet the EC design guidelines. The 3 units at the northernmost apex of the triangular site and the building containing 7 units on the northwestern property line are not expected to be visible from the EC. Accessory structures and equipment 17 Accessory structures and equipment should be integrated into No accessory structures or equipment are None. the overall plan of development and shall, to the extent illustrated on the site plans. A note on the possible, be compatible with the building designs used on the cover sheet (C 1) of the site plan set states site. each unit will have an individual trash can. 18 The following should be located to eliminate visibility from the The residential nature of this block Provide all proposed utilities Entrance Corridor street. If, after appropriate siting, these precludes the need for loading, service, and associated easements on features will still have a negative visual impact on the Entrance refuse (there will be typical single family the utility plans. Corridor street, screening should be provided to eliminate refuse, but dumpsters aren't expected), and visibility. a. Loading areas, b. Service areas, c. Refuse areas, storage areas. No mechanical equipment is Show mechanical equipment d. Storage areas, e. Mechanical equipment, shown, but residential -scale HVAC units on the site plans and/or f. Above -ground utilities, and g. Chain link fence, barbed are likely to be ground -mounted (possibly architectural plans if the wire, razor wire, and similar security fencing devices. roof -mounted); they may be visible from the mechanical equipment will be EC, depending on their placement. No roof -mounted. above -ground utilities are depicted on the utility plans (water, stormwater sewer, and sanitary sewer are the only utilities depicted and they are illustrated as underground), however, electricity, telephone, gas and other potential utilities are not included on this site plan set. No fencing is proposed. 19 Screening devices should be compatible with the design of No screening devices proposed. None. the buildings and surrounding natural vegetation and may consist of: a. Walls, b. Plantings, and c. Fencing. 20 Surface runoff structures and detention ponds should be 2 stormwater management (SWM) areas are None. designed to fit into the natural topography to avoid the need for proposed on an abutting parcel (TMP 76- screening. When visible from the Entrance Corridor street, 46A), adjacent to this parcel's northwestern these features must be fully integrated into the landscape. They boundary, one of which will serve the should not have the appearance of engineered features. subject parcel; TMP 76-46 is currently under review for subdivision for single- family detached home lots. No information other than general location is provided (i.e., the shape or nature of the SWM facilities). The SWM facilities are unlikely to be visible from the EC given their depressed grade and the configuration of the proposed buildings on the subject parcel. 21 The following note should be added to the site plan and the Note not provided. Provide the standard architectural plan: "Visibility of all mechanical equipment mechanical equipment note on from the Entrance Corridor shall be eliminated." the Cover Sheet (C 1) of the site plan set and on the architectural drawings. 22- Lighting No lighting plan was submitted. However, a If any outdoor lighting is 29 note on the cover sheet (C 1) of the site plan proposed, submit a lighting set states "no outdoor lighting is proposed plan for final review that on this site development plan." includes photometric values of all freestanding and wall - mounted lights as well as a luminaire schedule and manufacturer's specifications. Landscaping 32 Landscaping along the frontage of Entrance Corridor streets A Landscape Plan (C6) has been provided None. should include the following: in this site plan set. The proposed a. Large shade trees should be planted parallel to the landscaping is limited to 24 large shade Entrance Corridor Street. Such trees should be at least 3 %2 trees with a proposed planting caliper of 3.5 inches caliper (measured 6 inches above the ground) and inches and 16 ornamental trees with a should be of a plant species common to the area. Such trees proposed planting height of 6-7 feet; 12 of should be located at least every 35 feet on center. the shade trees and all 16 of the ornamentals b. Flowering ornamental trees of a species common to the area are proposed for the EC frontage, within the should be interspersed among the trees required by the right-of-way, while the remaining 12 shade preceding paragraph. The ornamental trees need not alternate trees are proposed on Wahoo Way. A new one for one with the large shade trees. They may be planted sanitary easement crosses into the front yard among the large shade trees in a less regular spacing pattern. of the westernmost townhouse, preventing c. In situations where appropriate, a three or four board fence planting along the EC in front of this unit. or low stone wall, typical of the area, should align the The species are unspecified in the plant frontage of the Entrance Corridor street. schedule provided in the landscape schedule d. An area of sufficient width to accommodate the foregoing provided on the Landscape Plan (C6). plantings and fencing should be reserved parallel to the Entrance Corridor street, and exclusive of road right-of-way and utility easements. 33 Landscaping along interior roads: 12 shade trees with (proposed) 3.5-inch Reduce the on -center distances a. Large trees should be planted parallel to all interior roads. caliper planting size are proposed along of the three trees proposed on Such trees should be at least 2%2 inches caliper (measured six Wahoo Way: 9 on the west side and 3 on the east side of Wahoo Way to inches above the ground) and should be of a plant species the east side. The on -center distances meet the 40' spacing common to the area. Such trees should be located at least between the 9 trees on the west side of requirement. every 40 feet on center. Wahoo Way vary between 35 and 40 feet, but the two on -center distances between the 34 Landscaping along interior pedestrian ways: a. Medium trees should be planted parallel to all interior 3 trees proposed for the east side of the pedestrian ways. Such trees should be at least 2% inches drive are 52 and 60 feet. caliper (measured six inches above the ground) and should be of a species common to the area. Such trees should be located at least every 25 feet on center. 35 Landscaping of parking areas: 8 parking spaces (divided into two groups Consider providing large a. Large trees should align the perimeter of parking areas, of 4, located on the southwest corner and in shade trees around the two located 40 feet on center. Trees should be planted in the the interior of the site) are devoted to guest guest parking areas in the interior of parking areas at the rate of one tree for every 10 parking; a note describes each unit center and in the southwest parking spaces provided and should be evenly distributed including 2 parking spaces. No interior site corner of the site. throughout the interior of the parking area. trees are proposed for the "recreational b. Trees required by the preceding paragraph should measured space" in the center of the site or the interior 2'/z inches caliper (measured six inches above the ground); streets/parking areas. No shrubs are should be evenly spaced; and should be of a species common proposed. to the area. Such trees should be planted in planters or medians sufficiently large to maintain the health of the tree and shall be protected by curbing. c. Shrubs should be provided as necessary to minimize the parking area's impact on Entrance Corridor streets. Shrubs should measure 24 inches in height. 36 Landscaping of buildings and other structures: No vegetation is proposed along the None at this time. a. Trees or other vegetation should be planted along the front building elevations. When architectural of long buildings as necessary to soften the appearance of drawings are submitted for review, the exterior walls. The spacing, size, and type of such trees or amount of additional landscaping needed vegetation should be determined by the length, height, and along the buildings can be determined. blankness of such walls. b. Shrubs should be used to integrate the site, buildings, and other structures; dumpsters, accessory buildings and structures; "drive thru" windows; service areas; and signs. Shrubs should measure at least 24 inches in height. 37 Plant species: While "large shade tree" and "ornamental See recommendation in 47 a. Plant species required should be as approved by the Staff tree" have been delineated on the Landscape based upon but not limited to the Generic Landscape Plan Plan (C6), no species have been specified. Recommended Species List and Native Plants for Virginia Landscapes (Appendix D). 38 Plant health: Note has been provided on the Landscape None. The following note should be added to the landscape plan: "All Plan (C6). site plantings of trees and shrubs shall be allowed to reach, d be maintained at, mature height; the topping of trees is ro hibited. Shrubs and trees shall be pruned minimally and dmy to support the overall health of the plant." Site Development and layout Development pattern 39 The relationship of buildings and other structures to the The proposed concept plan for the site Clarify the tie-in of the Entrance Corridor street and to other development within the layout exhibits an organized pattern of roads sidewalk at Wahoo Way's 10 corridor should be as follows: and an alley with two entrances onto Wahoo throat with proposed sidewalk a. An organized pattern of roads, service lanes, bike paths, Way. expansion and/or existing and pedestrian walks should guide the layout of the site. The configuration of the 5 proposed asphalt path throughout the b. In general, buildings fronting the Entrance Corridor street buildings conforms to the triangular shape site plan set. should be parallel to the street. Building groupings should be of the parcel, while 2 of the buildings are arranged to parallel the Entrance Corridor street. parallel to the EC street. Consider dedicating more c. Provisions should be made for connections to adjacent Provisions have been made for connections frontage along the southern pedestrian and vehicular circulation systems. to pedestrian and vehicular circulation property line to sidewalk d. Open spaces should be tied into surrounding areas to systems: the 2 blocks fronting the EC have improvements. provide continuity within the Entrance Corridor. entry walks that connect to an existing e. If significant natural features exist on the site (including pedestrian path, but that pedestrian path is creek valleys, steep slopes, significant trees or rock primitive (it is merely the asphalt outcroppings), to the extent practical, then such natural continuation of the road separated by a features should be reflected in the site layout. If the guardrail) and is currently an uninviting provisions of Section 32.5.6.n of the Albemarle County pedestrian environment. [Figures 5 and 6] Zoning Ordinance apply, then improvements required by that Sidewalk improvements will be requested section should be located so as to maximize the use of by the lead planner of the Site Development existing features in screening such improvements from Review. Entrance Corridor streets. The only proposed open space is sited f. The placement of structures on the site should respect within the development and will not be existing views and vistas on and around the site. visible from the EC. Managed slopes (wooded ravines) exist on the site which will make construction difficult without extensive grading; a significant portion of the existing treeline will be cleared for the building sites. I Figures S and 6: views of the pedestrian path on the subject parcel's southern property line, looking west. Photos taken by Heather McMahon 3115118. Site Grading 40 Site grading should maintain the basic relationship of the site to The natural topography on this site is vastly None. surrounding conditions by limiting the use of retaining walls variable, with deep ravines and a high knoll and by shaping the terrain through the use of smooth, rounded that appears to be earth removed from land forms that blend with the existing terrain. Steep cut or fill adjacent, previous development. The sections are generally unacceptable. Proposed contours on the proposed grading is extensive, especially in grading plan shall be rounded with a ten foot minimum radius the southeastern corner of the site, closest to where they meet the adjacent condition. Final grading should the EC. No retaining walls are proposed. achieve a natural, rather than engineered, appearance. Retaining walls 6 feet in height and taller, when necessary, shall be terraced and planted to blend with the landscape. 12 41 No grading, trenching, or tunneling should occur within the A "demo tree line" is illustrated on the Show tree protection fencing drip line of any trees or other existing features designated for Existing Conditions & Demo Plan (C2) in on the grading and landscape preservation in the final Certificate of Appropriateness. the far southwestern corner (dogleg) of the plans (C4 and C6). Adequate tree protection fencing should be shown on, and parcel; no individual trees have been called coordinated throughout, the grading, landscaping and erosion out for preservation. The majority of the and sediment control plans. parcel will be cleared for the proposed development. 42 Areas designated for preservation in the final Certificate of Appropriateness should be clearly delineated and protected on the site prior to any grading activity on the site. This The placement of the 2 SWM areas on the protection should remain in place until completion of the neighboring parcel do take advantage of development of the site. natural drainage patterns, as they are sited in lower -lying areas of the site. 43 Preservation areas should be protected from storage or movement of heavy equipment within this area. 44 Natural drainage patterns (or to the extent required, new drainage patterns) should be incorporated into the finished site to the extent possible. SUMMARY OF RECOMMENDATIONS Staff recommends the following as the primary points of discussion: 1. Improvement of the pedestrian path located adjacent to the EC for better organization and views. Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee: • Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and recommended conditions of initial plan approval: o Prior to Initial Plan approval the following items shall be resolved to the satisfaction of the ARB: None. • Regarding recommendations on the plan as it relates to the guidelines: 1. Consider providing large shade trees around the two guest parking areas in the center and in the southwest corner of the site. 2. Consider dedicating more frontage along the southern property line to sidewalk improvements. • Regarding conditions to be satisfied prior to issuance of a grading permit: None. • Regarding the final site plan submittal: 1. Submit architectural plans, elevations, and material samples for review with the final site plan. 2. Provide a landscape plan that addresses all EC landscape guidelines, complete with plant schedule, for review with the final site plan. 3. Provide all proposed utilities and associated easements on the utility plans. 4. Show mechanical equipment on the site plans and/or architectural plans if the mechanical equipment will be roof -mounted. 13 5. Provide the standard mechanical equipment note on the Cover Sheet (C 1) of the site plan set and on the architectural drawings: Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 6. If any outdoor lighting is proposed, submit a lighting plan for final review that includes photometric values of all freestanding and wall - mounted lights as well as a luminaire schedule and manufacturer's specifications. 7. Reduce the on -center distances of the three trees proposed on the east side of Wahoo Way to meet the 40' spacing requirement. 8. Clarify the tie-in of the sidewalk at Wahoo Way's throat with proposed sidewalk expansion and/or existing asphalt path throughout the site plan set TABLE A This report is based on the following submittal items: Sheet # Drawing Name Drawing Date/Revision Date CI Cover Sheet 2/20/18 C2 Existing Conditions & Demo Plan 2/20/18 C3 Site Plan 2/20/18 C4 Grading Plan 2/20/18 C5 Utility Plan 2/20/18 C6 Landscape Plan 2/20/18 14