HomeMy WebLinkAboutSDP201600076 Application Final Site Plan and Comps. 2017-12-27 Albemarle
community Development Department
� te434)2re
e32
Fax:(434)972-4126
a Planning Application
PARCEL/ OWNER INFORMATION
TMP07700-00-M-040110 Owner(s): ELEMENTAL ECOTECH LLC
Application# JDP2OI 600078
PROPERTY INFORMATION
Legal Description I ACREAGE 3&PARCEL 6 ..
Magisterial Dist.1Scottsville Land Use Primary Open
Current AFD 'Not in A/F DistrictCurrent Zoning Primary'Light Industry +R
APPLICATION INFORMATION
Street Address Entered By
Application Type !Site_-... 'Jennifer Smith
A
PP yp tDevelopment Plans (i7 2016
Project Woolen Mills Light Industrial Park- Final
Received Date 12/22/16 Received Date Final Submittal Date 12/27/16 Total Fees 1613
Closing File Date Submittal Date Final Total Paid 1613
Revision Number
Comments
Legal Ad
SUB APPLICATION(s)
Type Sub Apiicatio Comment
APPLICANT /CONTACT INFORMATION
CowttactType I N Address I CityState Zip ll
agintr. ELEMENTAL ECOTECH LLC 1808 BOLLING AVE UNIT C ?CHJ RLOTTES fILU. 122902
oe mary Ccet t MICHAEL MYERS.PE 172 SOUTH PANTOPS DR CHARLOTTESVILL 22911 4349798121
Signature of Contractor or Authorized Agent Date
V v
L
likao
Application for
Initial Site Plan or Final Site Plan or Site Plan Exception •
�>RcaN�r
Project Name: Woolen Mills 1:131,11- Ih lLtsi .l Park
Tax map and parcel(s): "1"1- yo 6 ,4a C 1 Zoning: LI.
Contact (who should we contact about this project) M i[,I"We 1 My 4.rS 126.
Street Address VIZ So K+1^ Po.r14- ors- Dr. S•4:4 a A
City C-Le•r- it4FtSVIkt State VA Zip Code ZZ9l
Phone Number 434 - 979 - Email 0101 er .n•*A ton , Corin
Owner of Record C LA.,e.✓t+a.l E +&% , L L L
CI Street Address $0 1 € .I I ;'13 Ave. (✓;.-{-
City Ci1^ s r-1.4,eSvi I L State VA Zip Code 2.2.-9 OZ
Phone Number Email
Applicant
Street Address
City State Zip Code
Phone Number Email
Type of Development
❑ Residential U7/ Non-residential
Type of unit(s): 0 Commercial
ar Industrial
#of building(s):
U Quasi-Public
Sq.ft.of building(s): Sq.ft.of building(s): 1011,10 o
#of units per building: Acreage of site: 13,8 (o
Total#of units: Acreage in open space:
Resulting density: Acreage in roads:
Acreage of site: Average gallons of water used per day: _
Acreage in open space:
Acreage in roads:
Average gallons of water used per day:
FOR OFFICE USE ONLY SDP# &D\v� i (( /
Fee Amount$4'L/ ' Date Paid 422/4 By who? &1417aid /A Receipt#107 59Ck#oho I) By: J P
County of Albemarle
Department of Community Development
401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434)972-4126
REVISED 11/02/2015 Page 1 of 2
Intended use or justification for request:
Comments/Attachments:
FEES
SITE DEVELOPMENT PLAN SITE PLAN EXCEPTION
Initial Site Plan Final Site Plan Exception to drawing of site
plan under section 32.3.5(a)
Approved No
Preapplication plan Preapplication plan
❑ $752 plus$16/dwelling ❑ $1,290 plus$16/dwelling $1,613 U $1,613
unit and/or 50.016 per unit and/or$0.016 per
square foot of square foot of
nonresidential structure nonresidential structure
$ $
16 folded copies of the plan #of copies required for submittal will be noted with 8 folded copies of the plan
plus an additional 6 copies if within an Entrance Corridor your initial approval letter. Copies of the plan should
be folded and in blue or black ink.Also provide 1
reduced copy of the plan no larger than 11 by 17 in.
❑ The initial site plan has a parking structure. ❑ The final site plan has a parking
❑ Included are architectural elevations,drawings, structure.
photographs or other visual materials showing any ❑ Included are revised architectural elevations,
parking structure proposed on the site and surrounding drawings,photographs or other visual
structures and land uses. materials submitted with the initial site plan.
The elevations shall be part of the approved
final site plan.
GROUNDWATER ASSESSMENT
(Required for all non-residential site plans not serviced by public water)
❑ If the plans show a use using less than 2,000 gallons/day(average) Tier 3 Groundwater Review=$548
❑ If the plans show a use using greater than 2,000 gallons/day(average) Tier 4 Groundwater Review=$1,183
❑ Special Exception=$457
Notices required by Section 32.4.2.1 (f)
Preparing and mailing or delivering up to fifty(50)notices=$215.00 plus the actual cost of first class postage.
Preparing and mailing or delivering,per notice more than fifty(50)=$1.08 plus the actual cost of first class postage.
Owner/Applicant Must Read and Sign
This site plan as submitted contains all of the information required by Section 32.5(Initial Site Plan)or Section 32.6(Final Site Plan)of
Chapter 18 of the Code of the County of Albemarle. I understand that plans which lack information required by said sections shall be
deemed incomplete and shall be denied by the agent within ten(10)days of submittal as provided in Section 32.4.2.1 or Section 32.4.3.1
of Chapter 18 of the Code as the case may be.By signing this application I am consenting to written comments,letters and or notifications
regarding this application being provided to me or my designated contact via fax and or email. This consent does not preclude such
written communication from also being sent via first class mail.
For Final Plan Only:To he best of y knowledge,I have complied with Section 32.4.3.1(a)of Chapter 18 of the Code.
Signature of Owner,Contract Purchaser,Agent Date
u- 7P$4-47t. batgArL5s>� (��' , `7 -3134-
Print Name Daytime phone number of Signatory
REVISED 11/02/2015 Page 2 of 2
4000 .. •
RECEIVED
DEC 2 2 2016
COMMUNITY
DEVELOPMENT
*41001
c�°`5 172 South Pantops Drive
��-� I" Dominion
� Engineering Charlottesville, VA 22911
434.979.8121 (p)
as s
" ' � . 434.979.1681 (f)
'ems: DominionEng.com
Transmittal Cover Sheet
To: JT Newberry Date: 12/22/2016
Senior Planner
Address: Community Development Transmitted: Q By Mail
401 McIntire Road
0 By Hand
From: Mike Myers
By Email
Application: Final Site Plan
Project: Woolen Mills Light Industrial Park For Pick-up
Project#: SDP201600059
Quantity Item Description
9 Sets of Final Site Plan
1 Final Site Plan Checklist
1 Application for Final Site Plan
1 Flood Development Permit
1 Comment Respoonse Letter addressing ISP comments
1 Check for$1,613
Comments:
Delivered by: 0 Dominion
Engineering
Client
Received By: Other
Date:
For Pick-up: J At Dominion
CC: Engineering
RECEIVED
DEC 222016
OMMUNITY
r�`v/ELOPMENT
Erre *.r/
� pF A aar_
+7
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road
Charlottesville,Virginia 22902-4596
Phone(434)296-5832 Fax(434)972-4126
FLOODPLAIN DEVELOPMENT PERMIT
This form is intended to aid the Department in documenting and characterizing the nature of development proposed in the
floodplain. Development includes buildings or other structures,mining,dredging, filling,grading,paving,excavation or
drilling operations or storage of equipment or materials. The form responses will be used to determine whether a
floodplain impact plan or special use permit is required.
Please check one: [ New Submittal with no anticipated floodplain impact(no floodplain impact plan)
❑ New Submittal with an anticipated floodplain impact. Please include a floodplain impact
plan. FEE required with submittal: $323(Code 18-35.1g)
❑ FEMA Letter of Map Change(LOMA,LOMR) Please include a complete copy of all
material to be submitted to FEMA. Include any computer models (HEC-RAS files)on a disc.
FEE required with submittal: $161 (topographic info only),or$323(floodplain
modeling)
❑ New Submittal with a Zoning Special Use Permit.Please include a floodplain impact plan.
FEE required with submittal: $323
O Resubmittal (Floodplain Development Permit Number ) Please include your
response form from the original submittal. FEE as above required with each resubmittal.
A Floodplain Impact Plan, Special Use Permit, or FEMA Map Change will need to follow Zoning Floodplain Overlay
District requirements(County Code 18-30.3),found at
http://www.albemarle.org/upload/images/Forms Center/Departments/County_Attorney/Forms/Albemarle County Code_
Chl8 Zoning30 Overlay Districts.pdf
Section 4 of the Design Standards Manual provides a list of required items to be included in a Floodplain Impact Plan.
This can be found at http://www.albemarle.org/department.asp?department=cdd&relpage=4447.
E e"•tv 4-o I Eco kc��. � L L L Stio - 721 - 3131-1 SA/v,it;
Owner Name(Print) Home Phone Office/Other Phone
8041 So 11;..x.
Avg_ t i t C
Address
1. Q.Svikkt VA 27102
City State Zip Code
Tax Map& Parcel Number '17 - t.0 Q 1loC.1
r
Project Name(if applicable) Wool S :)ln 4- 1 K S 4 CO 1 Pyr L
Building Permit or Project Number(if applicable) r•.) .-4. t 4- a f(11)A C A
11/1/2015
I
SW" *4109
Please describe the nature of the development activity proposed within the floodplain (e.g. new structure, grading for a
playing field, driveway stream crossing, installation of a fence,etc.):
4r4 w; Lk b *. coft re... r',nc kSk-0,01 .1 it core
(Please attach any plans or photos to this application)
1. If a structure is proposed, is the structure accessory to a recreational or agricultural use? Yes❑No N/A
2. Does the proposed activity involve a stream crossing for a pedestrian trail or driveway
serving a single family dwelling? Yes❑No 2, N/A
3. Does any proposed fencing cross a stream channel? Yes❑No �N/A
4. If any fill is proposed,please approximate the proposed amount of fill in the floodplain (.�A
Owner/Agent Signature(' -Z� Date (2'/ i I I (p
(FOR OFFICE USE ONLY)
Checked By Date
(for resubmittals) Fee Amount$ Date Paid By Who?
Receipt# Check#
11/1/2015
(600
•
RECEIVED
DEC 222016
COMMUNITY
fiEVLLOPM :NT
c r
Final ite Development Planacaotzs
Checklist
Project Name: WOO I L i% M i 11 S 1.,-131%# .L,4 s 4 r►'od Pc.r is
Firm: Poieh;,�; •• Ehq v�.ec n' 0tS
This checklist must be completed,signed and sumitted with the application. The information contained in this
checklist reflects the contents of the Section 32 of Chapter 18 of the Code of the County of Albemarle also known as
the Site Plan Ordinance as of January 1,2013. The applicant is responsible for insuring that no revisions to the
Ordinance have occurred since preparation of this document.
This final site plan has:
gan initial site plan that was approved for the development and it remains valid; SDP-20 I - O°0 S9
rEf/ satisfied all of the requirements of section 32.6 below;and
satisfied all of the conditions delineated in the letter provided under section 32.4.2.5(c)required to be satisfied prior to
submitting the final site plan.
Eit Author] ed preparer.
13 The plan,and any amendments to a plan,is prepared and sealed,signed and dated by one of the following
❑ An architect licensed to practice in the Commonwealth of Virginia.
Ci A professional engineer licensed to practice in the Commonwealth of Virginia.
❑ A land surveyor licensed to practice in the Commonwealth of Virginia.
❑ A certified landscape architect licensed to practice in the Commonwealth of Virginia.
Number of copies when first submitted.
Er Provide the number of copies as directed in the Initial Site Plan approval letter 1 Ca le
• One(1)reduced copy of the plan no larger than eleven(11)by seventeen(17)inches in size. 3 AC {k
12r.Scale and size.
3/The plan is prepared to the scale of one(1)inch equals twenty(20)feet or larger,or to another scale approved by
the agent in a particular case.
❑ Other scale approved -one(1)inch equals ( )feet,by
12(No sheet exceeds forty-two(42)inches by thirty-six(36)inches in size.
Ca/The plan IS prepared on one(1)sheet.OR
U The plan IS prepared on more than one(1)sheet and match lines clearly indicate where the several sheets join.
C3'The top of each sheet is approximately
❑ North or
❑ East
lir Dimensions.
The plan is dimensioned to at least the following standards for accuracy:
• Boundary,setback and zoning lines:Within one one-hundredth(0.01)of a foot.
• Existing contours:Within one-half(1/2)of the contour interval required in section 32.6.2(c).
Cr Proposed contours: Within one(1)foot horizontally and vertically.
a/Spot elevations: Within one-tenth(0.10)of a foot.
UK Existing critical structures including utilities and other topographic features:Within two(2) feet,
provided that for critical structures,which include,but are not limited to,gas lines,other utilities,pipes,
conduits,walls and buildings to be preserved,within one-tenth(0.10)of a foot.
Proposed structures,roads,parking lots and other improvements: Within one one-hundredth(0.01)of a
foot.
REVISED 06/10/2015 Page 1 of 4
40110
No/ AVemarle County-Final Site Plan Checklist
Site Plan Ordinance Section 32.6-Contents of final site plan
In addition to containing all of the information required to be on an initial site plan, as provided in section 32.5, a final
site plan shall contain the following:
Demonstrate compliance with chapter. Specific written schedules or notes as necessary to demonstrate that the
requirements of this chapter are satisfied.
Propos d grading.
Proposed grading(up to twenty [20] percent slope,maximum two [2] foot contours;over twenty [20]
percent slope,maximum five [5] foot contours).
O/ Water and sewer facilities.
Er Detailed plans for proposed water and sewer facilities,including all pipe sizes,types and grades;
13 proposed connections to existing or proposed central water supplies and central sewage systems;
Cil' location and dimensions of proposed easements and whether they are to be publicly or privately
maintained;
C3 profiles and cross sections of all water and sewer lines including clearance where lines cross;
Er all water main locations and sizes;valves and fire hydrant locations;
Er all sewer appurtenances by type and number;
Ethe station on the plan to conform to the station shown on the profile and indicate the top and invert
elevation of each structure.
Drainaie and grading plans.
Detailed constryction drainage and grading plans:
L- Profiles of all ditches and channels whether proposed or existing,showing existing and
proposed grades,and invert of ditches,cross pipes or utilities;typical channel cross
sections for new construction;and actual cross sections for existing channels intended
to remain;
a Profiles of all storm sewer systems showing existing and proposed grades;
Plan view of all drainage systems with all structures,pipes and channels numbered or
lettered on the plan and profile views. Show sufficient dimensions and bench marks to
allow field stake out of all proposed work from the boundary lines;
LI A drainage summary table for culverts, storm sewer and channels as described in the
following example:
Structure Description Length Invert Invert Slope Remarks
Number In Out
1 42"RCP 50' 24.50 424.00 100.00% Provide
Class III 2, EW
2 DI-3B L=8 26.00 432.00 - IS-1
Top
3 PG-2A 400' 420.00 400.00 5.00% D=12"
4 Grade 200' 420.00 415.00 2.50% D=18"
Swale
A legend showing all symbols and abbreviations used on the plan;
IW" General notes,typical sections,and details of all items not covered by Virginia
Li(F)epartment of Transportation standard drawings; and
lood plain limits for the one hundred(100)year storm for all watercourses with an
upstream drainage area of fifty(50)acres or more provided that the county engineer
may waive this requirement for drainage areas of less than one hundred(100)acres
upon determining that the information is unnecessary for review of the proposed
development.
REVISED 06/10/2015 Page 2 of 4
‘40 isr)
*marle County-Final Site Plan Checklist
"Street ctions.
"Typical street sections together with specific street sections where street cut or fill is five(5)feet or
greater;
Or/centerline curve data;
L�� radius of curb returns or edge of pavement;
C3 location,type and size of proposed ingress to and egress from the site together with culvert size;
2/symmetrical transition of pavement at intersection with existing street;
❑>the edge of street surface or face of curb for full length of proposed street;
ld when proposed streets intersect with or adjoin existing streets or travelways,both edges of existing
pavement or travelway together with curb and gutter indicated for a minimum of one hundred(100)
feet or the length of connection,whichever is the greater distance.
'Public facilities and utilities.
a All public facilities,utility and drainage easements outside the right-of-way of public streets,provided
2hat new easements may be generally shown and accurately dedicated by separate plat.
All water and sewer facilities to be dedicated to public use and the easements for those facilities and
shall be identified by a statement that the facilities are to be dedicated to the Albemarle County Service
Authority.
C( Signature panel.
C3"Signature panel for signature by each member of the site review committee.
2"Parkin nd loading areas.
3 For all king and loading areas, indicate the
size,
angle of stalls,
width of aisles and specific number of spaces required and provided,and
/ method of computation. Indicate type of surfacing for all paved or gravel areas.
1a Landscape plan.
2'A landscape plan that complies with section 32.7.9
ZOutdoor lighting.
3/Outdoor lighting information including
❑ a photometric plan with
❑ location,description,and photograph or diagram of each type of outdoor luminaire.
N AI Recreational facilities.
U Specifications for recreational facilities.
In addition to the items required by the ordinance,Albemarle County Engineer,the Virginia
Department of Transportation,the Albemarle County Service Authority,and the Thomas Jefferson
Health District require these items on plans submitted for final site plan approval. Plans will not be
rejected if these items are not present, but they are required for approval. These items are provided in
an effort to communicate all final site plan comments.
12/1. Reference the benchmarks used for surveys. (Albemarle County Engineering Policy)
12. Indicate the available sight distance for entrances and left turn lanes. (Albemarle County Engineering Policy)
EI 3. Label the maximum height of all retaining walls. (Albemarle County Engineering Policy)
d 4. Provide copies of off-site easements,or letters of intent to grant them from off-site property owners.
(Albemarle County Engineering Policy)
REVISED 06/10/2015 Page 3 of 4
41.0
Aeemarle County-Final Site Plan Checklist
Mt% 5. Show and label stream buffer limits. (Water Protection Ordinance,WPO)
C(6. Indicate the deed book and page reference for all existing utility easements located on the property.
(Albemarle County Service Authority)
KM 7. Tier 3 -Draft or Final Groundwater Management Plan(WPO Section 17-403)
NO A 8. Tier 4—Aquifer testing work plan(WPO Section 17-403)
Read and Sign
In representing the above referenced firm submitting this plan for final approval,I hereby sate that,to the best of my knowledge,the attached plan
contains all information required by this checklist.
2I /Z•( (�
Sign ure of Or,Contract Purchaser,Agent Date
C . G rcc c 43L1 _ 971 - 6121 e.)-1-((
Print Name Daytime phone number of Signatory
REVISED 06/10/2015 Page 4 of 4
Nair
440
RECEIVED
DEC 2 2 2016
COMMUNITY
DEVELOPMENT