Loading...
HomeMy WebLinkAboutSUB201700102 Application 2017-12-07 Page 1 COUNTY OF ALBEMARLE APPLICATION FOR ROAD PLAN APPROVAL Is this an amendment to an approved plan? Yes❑No Is this a revision or resubmission for review?Yes No❑ County File Number:SUB201700102 (to be provided by County for new applications) 8 Copies of the Plan to be submitted and distributed by the County as follows: 2 Copies to County Engineering 1 Copy to Albemarle Fire and Rescue 1 Copy to Planning for Street Trees and other landscaping review 2 Copies to Albemarle County Service Authority 2 Copies to Virginia Department of Transportation Have you submitted plans separately to any agencies listed above?Yes ❑ No% List Agencies: Project Name HYLAND PARK Tax map and parcels 078E0-00-00-000A0 Zoning R-4 RESIDENTIAL WITH PROFFERS (ZMA 04-18 APPROVED MARCH 19, 2008) Physical Street Address(if assigned): OFF FONTANA DRIVE AND VIA FLORENCE ROAD Applicant COLLINS ENGINEERING Street Address 200 GARRETT STREET, SUITE K City CHARLOTTESVILLE State VA Zip Code 22902 Phone Number 434-293-3719 Email scoff@collins-engineering.com Owner of Record HIGHLAND PARK, LLC Street Address 455 SECOND STREET SE, SUITE 400 City CHARLOTTESVILLE State VA Zip Code 22902 Phone Number Email Contact(who should we contact about this project):SCOTT COLLINS-COLLINS ENGINEERING Street Address 200 GARRETT STREET, SUITE K City CHARLOTTESVILLE State VA Zip Code 22902 Phone Number 434-293-3719 Email scott@collins-engineering.com County of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434)972-4126 Paget COUNTY OF ALBEMARLE APPLICATION FOR ROAD PLAN APPROVAL Owner/Applicant Must Read and Sign The foregoing information is complete and correct to the best of my knowledge. I have read and understand the provisions of Chapter 14 Subdivision of Land of the Albemarle County Code,and the Design Manual,and am consenting to all correspondence from Albemarle County be in any of the following forms in writing;by first class mail,by personal delivery,by fax or,by email. ______IF ill[2,ot1 Signature of Owner,Contract Purchaser,Agent Date SCv4f ebt4S 434-A5-ZiI Print Name Daytime phone number of Signatory el 00 FOR OFFICE SE ONLY SUB# Fee Amount$ L/`n ,, Date Paid f 2 7 Page COUNTY OF ALBEMARLE APPLICATION FOR ROAD PLAN APPROVAL FEES ROAD PLANS FOR PROPOSED SUBDIVISION *If public and private streets are proposed,pay the higher of the two fees(private street) 8 copies of the road plan are required for all submittals Public Street Fees Private Street Fees El For each review of a submitted plan,including re- U Authorization of one or more private streets within views of revisions after plan approval=$269 a subdivision filed separately from a subdivision appli- cation=$720 ❑ For each review of a submitted plan,including re- views of revisions after plan approval =$430 VARIATIONS OR EXCEPTIONS BEFORE APPROVAL OF A PRELIMINARY PLAT ❑ Variation to or exception from street interconnection requirements=$581 ❑ Variation to or exception from one or more street standards=$581 ❑ Variation to or exception from curb and/or gutter requirements=$581 AFTER PRELIMINARY PLAT APPROVAL AND BEFORE FINAL SUBDIVISION PLAT APPROVAL U Variation to or exception from any requirement of Chapter 14 for which a variation to or exception from is au- thorized after approval of a preliminary plat and before approval of a final plat=$892.00. Attach written justifica- tion AFTER FINAL PLAT APPROVAL U Variation to or exception from any requirement of Chapter 14 for which a variation to or exception from is au- thorized after approval of a final plat=$892.00. Attach written justification SURETYBONDING If required to construct a street,the subdivider shall pay to the county a fee equal to the cost of the inspection of the con- struction of any such street.These fees shall be paid prior to completion of all necessary inspections and shall be deemed a part of the cost of construction of the street for purposes of section 14-435(B). The bond process and forms can be found at the document center under bonds.After a plan is approved,a bond estimate request form must be submitted to the Community Development office with the required fee. The owner signatures will be verified for each parcel affected,and estimates will be prepared by the engineering reviewer. A bond amount will be pro- vided to the owner. Bond agreements will be prepared by the county,and when properly completed by the owner,will be reviewed and signed by the County Attorney and County Engineer. Please allow a few weeks for this process. Page COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST A road or street plan is an engineered construction plan for a public or private road or alley. It also contains necessary infrastructure for the road, like drainage inlets,pipes,ditches, culverts,residential and commercial entrances, slopes, retaining walls, signs,pavement markings and any other items necessary for the road. A road plan must be a stand-alone document, and titled as a road plan.A road plan is not a site plan, or a stormwater plan, or an erosion control plan. Please do not attach any other plans to the road plan. The exception is when the Albemarle County Service Authority has insisted in some cases that utility plans(water and sewer)be part of the road plans, and this has been permitted. A road plan must contain a title sheet specifically for the road plan, a plan view of the road, a profile of the road, and specific and typical details for the road sections. Please also reference the Design Manual in addition to this checklist. Application information: ❑ Completed application and fees. No review is provided without applications and fees. Plans containing both public and private roads should pay the higher fee for private roads. ❑ Copies of federal and state permits for any wetland or stream disturbance. (Army Corps,VDEQ, etc) [18-32.1.2, 14-311] Title information: ❑ Project title. Titles should be appropriate. It should be a road or street plan,not a site plan, subdivision plan, or erosion control plan, etc. ❑ Professional seal,with original signature and date. ❑ Content: The road plan must contain, for each road/street/alley, at a minimum 1. a plan view,customarily at 1"=50' or better. 2. a profile view 3. a typical cross-section Plan View: [18-32.6.2, 14-304, Subdivision Ordinance Article IV Division 2, VDOT SSAR] ❑ Accurate current existing topography at the time of submittal, including all existing site features, and any recent disturbances, all at a legible scale. ❑ Date and source of the topographic information: All topography should be at least visually field verified by the designer within the last year {Aerial topography is often noticeably inaccurate. Disturbances sometimes take place subsequent to the flown date. This can be a particularly recurring problem where early or mass grading plans have occurred previously. In these cases,the topography needs to be updated.) ❑ WPO buffer limits; 100' from stream or wetland bank, 200' from reservoirs, or floodplain limit if greater [17-600] ❑ Floodplain limits, including 100yr flood limits for any channel with a drainage area of 50+acres [18 -32.6.2d, 18-30.3] ❑ All existing easements (access, drainage, sight, sanitary easements, etc.)with deed book references, locations and dimensions. Page COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST ❑ All proposed streets included,with right-of-way and street names ❑ Stationing at 50' minimum on all proposed streets, on plan and profile ❑ Street horizontal curve start point, end points and radii labeled,meeting standards ❑ Cul-de-sacs provided on all dead-end streets or alleys (see the Design Manual reference details) ❑ Street edge of pavement or curb radii labeled at all intersections and turnarounds(see the Design Manual reference details) ❑ Roundabouts designed per VDOT and ASHTO guidelines ❑ Guardrail over any slope steeper than 3:1, wall, or drop-off greater than 4', with start and end sections labeled, and VDOT designations(GR-2, GR-2a, etc.) (see the VDOT Road Design Manual. Guardrail placement is complicated and subject to a lot of judgement and variation. This is a quick rule -of-thumb summary.) ❑ Pavement markings dimensioned and labeled ❑ Signs for traffic control shown and labeled: speed limit on all streets, stop signs at all intersections ❑ Street name signs at every intersection, typically placed opposite stop signs [should reference County Road Naming and Property Numbering Ordinance and Manual] ❑ Street tree locations, species and height or caliper(typically to be reviewed by Planning) Grading: ❑ Proposed topography at minimum 2' contour intervals—tied into existing contours, as well as all proposed site features. (Sites with less than 6' of grade change should consider using smaller contour intervals.) ❑ Proposed slopes are all 2:1 (horizontal:vertical)or flatter {Design Manual, section 8} ❑ Proposed slopes steeper than 3:1 have low maintenance(not grass) ground cover specified on the plan {Design Manual, Section 8} ❑ Show existing critical(steep) slopes on plans (See County GIS, Steep Slope Overlay). Existing critical slopes are not disturbed,unless a waiver or exemption has been granted for the disturbance. ❑ Retaining walls should be accurately shown on plans,reflecting material thickness and batter where such measurements may affect layout. Retaining Wall Plans checklist. ❑ Any walls supporting roads or necessary infrastructure require engineered plans(not generic manufacturer's details)and computations. {Design Manual, section 8} This will also be required where walls are close to property lines and there is the danger of affecting neighboring property, either during construction,with later failures, or with pedestrian or vehicle safety. These concerns can be alleviate with layout spacing also. In any case, retaining walls will require building permits at construction. Required Easements: [Zoning Ordinance 18-32.7.4, Subdivision Ordinance, Article IV,Div. 4] ❑ All proposed permanent easements, dimensioned and labeled Examples of easements are: • sidewalk easements for sidewalks to be maintained with streets outside right-of-way. It is preferable that sidewalk be inside street right-of-way. • drainage easements for any drainage passing through the site from off-site, or for drainage crossing proposed property lines. • stormwater management easements over all facilities and associated structures and access • interparcel access easements • intersection or entrance sight easements Page 6 COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST ❑ All drainage easements are a minimum 20' wide. Required width: 10'+(pipe dia. or channel width) +2'+2(depth-5'). The pipe,channel or structure must be within the center third of the easement. {Design Manual, section 6) ❑ No structures or trees within drainage easements {Design Manual, section 6) ❑ Label drainage easements beyond public rights-of-way as `Private'. A deed of easement for the maintenance of these will be required for approval. Entrances and right-of-way improvements: [per VDOT Secondary Street Acceptance Requirements (SSAR), and VDOT Road and Bridge Standards] ❑ Only approved entrances are shown. Placing entrances on road plans should not be a way of circumventing site plan review of entrance placement or number, or adequate review of traffic, spacing, turn lanes, etc. ❑ All entrances have a VDOT designation [PE-1, CG-9a, etc). In the case of dense residential development, concrete entrance aprons are important to continue drainage on the street side, and to control fine grading of asphalt and sidewalks. ❑ Commercial entrances do not exceed 4%grade for a distance of 40' from the intersected street, measured anywhere in the entrance [18-4.12.17] ❑ Unobstructed sight distance lines at entrances, more than 10' x speed limit,plus next 5mph increment. For example: sight distance for 25mph design speed limit= 10' x 25 +30=280'. See VDOT Road Design Manual, App B1, Sec. 3E ❑ 25' minimum radii on entrances (or per VDOT requirements,typically 25'-35') [per VDOT Access Management Regulations and Standards] ❑ Turn and taper lanes where applicable with lengths and widths labeled (taper at 12:1 with 12' lane widths) Profile View: (applicable only to road or street plans) ❑ Stationing at 50' minimum on all proposed streets,to match the plan view sheets ❑ Proposed centerline ❑ Existing ground centerline(Historically,the existing centerline was field surveyed,but this is happening much less with current aerial topography. This may be requested if inaccuracies are noted.) ❑ Labeled existing and proposed grade at each 50ft station point ❑ Vertical curves provided at all grade transitions ❑ Vertical curve start, vertex and end points labeled ❑ Vertical curve length and K(or stopping sight distance) labeled at each vertex,meeting required design values ❑ Percent grades labeled for all road segments,meeting design values (VDOT Road Design Manual, App. B) ❑ Rural street intersections continue the -2%intersected cross grade for a minimum of 20' from the edge of pavement of the intersected street. A low point is provided off the intersected street for drainage. {policy, following VDOT practice) ❑ Street grade is less than 4%for a minimum of 40' from the edge of pavement of the intersected street. (This grade can be within the first road curve which transitions from the 2% intersected cross grade) {policy, follows ord. for travelways 18-4.12) ❑ Pipe and utility crossings shown and labeled(ACSA has minimum clearances) Pagel COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST ❑ Cross drain locations shown and labeled with VDOT designations(CD-1,2) at every major cut and fill transition or sag curve ❑ The station of intersections are shown and labeled with the street names ❑ Grades are a maximum of 6%in turnarounds ❑ Grades are a maximum of 4%through roundabouts Details and Sections: (reference VDOT Road Design Manual, or Sub. Ord.) ❑ Typical sections for each street, street segment, or alley ❑ Typical sections for sidewalks and trails ❑ Albemarle County general construction notes for streets (reference) ❑ Traffic generation and distribution summary(ADT's)with road networks ❑ Pavement designs per VDOT guides [2009 VDOT Pavement Design Guide for Subdivision and Secondary Roads in Virginia] ❑ Pavement widths meeting design standards ❑ Pavement crown at 1/4":1' slope ❑ Pavement surface,base, and sub-base thicknesses and materials ❑ Curb and gutter where applicable with VDOT designation(CG-6), and stone base of 6"21-A or better(CG-2 also acceptable if a gutter is not needed for drainage) ❑ Shoulder at 1":1' slope or flatter and 4' or greater width for rural sections ❑ Maximum slopes of 2:1 or flatter with guardrail shown where applicable. ❑ Proposed slopes steeper than 3:1 have low maintenance (not grass) ground cover specified on the plan E Guardrail over all fill slopes and culverts,with 3' additional shoulder,using VDOT designations (GR-2, GR-2A, etc.) ❑ Right-of-way/easement width, centered on street, meeting design standards ❑ Sidewalk location and widths,minimum 5' width, 4"concrete surface,4"21-A stone base with wire/ rebar reinforcement, with underdrains (UD-4,etc)per VDOT standards where applicable ❑ Sidewalks shall not be less than 4 inches thick, except when used in conjunction with roll top curb, in which case the thickness shall be 7 inches. See Section B(1)-4.G Curb and Gutter Designs, Figure 6- Detail Back of Curbs in VDOT Road Design Manual E Planting strip if applicable, 6' minimum width [14-422] ❑ Ditches dimensioned at 3:1 slope from shoulder, 1' depth min., and 4' min. width from shoulder to ditch centerline, for rural sections ❑ Alleys have 12' pavement width,with 14' wide stone base [14-410] ❑ Transitioning detail(20' minimum) for roll-top curbing in front of any inlets ❑ Typical sections for proposed channels with locations referenced from the plan view sheets ❑ Sidewalk detail or specification to be a minimum 4"stone base and 4"concrete of 3000psi at 28 days, or stronger. [VDOT App. B, Subdivision Street Design Guide, and 14-422] ❑ Retaining wall details referenced from plan, if detailed plans and comps were not required. This is only really applicable to standard VDOT gravity walls. Walls not affecting the road should not appear on road plans. ❑ Rural section ditches may not be deep enough for 15"diameter culverts within the ditchline if the ditches are only 1' deep. This usually involves moving the ditchline away from the road at driveway locations,which may not be possible in denser development. Ditch and driveway culvert plans will need to accommodate these situations. Page 8 COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST Read and Sign In representing the above referenced firm submitting this road plan for approval,I hereby state that,to the best of my knowledge,the attached road plan contains all information required by this checklist. Signature of person completing checklist Date Page , COUNTY OF ALBEMARLE APPLICATION FOR ROAD PLAN APPROVAL Is this an amendment to an approved plan? Yes❑No WI Is this a revision or resubmission for review?Yes lil No❑ County File Number:SUB201700102 (to be provided by County for new applications) 8 Copies of the Plan to be submitted and distributed by the County as follows: 2 Copies to County Engineering 1 Copy to Albemarle Fire and Rescue 1 Copy to Planning for Street Trees and other landscaping review 2 Copies to Albemarle County Service Authority 2 Copies to Virginia Department of Transportation Have you submitted plans separately to any agencies listed above?Yes X No ❑ List Agencies: ,ACSA Project Name HYLAND PARK Tax map and parcels 078E0-00-00-000A0 Zoning R-4 RESIDENTIAL WITH PROFFERS (ZMA 04-18 APPROVED MARCH 19, 2008) Physical Street Address(if assigned): OFF FONTANA DRIVE AND VIA FLORENCE ROAD Applicant COLLINS ENGINEERING Street Address 200 GARRETT STREET, SUITE K City CHARLOTTESVILLE State VA Zip Code 22902 Phone Number 434-293-3719 Email scott@collins-engineering.com Owner of Record HIGHLAND PARK, LLC Street Address455 SECOND STREET SE, SUITE 400 City CHARLOTTESVILLE State VA Zip Code 22902 Phone Number Email Contact (who should we contact about this project):SCOTT COLLINS-COLLINS ENGINEERING Street Address 200 GARRETT STREET, SUITE K City CHARLOTTESVILLE State VA Zip Code 22902 Phone Number 434-293-3719 Email scott@collins-engineering.com County of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434)972-4126 Paget COUNTY OF ALBEMARLE APPLICATION FOR ROAD PLAN APPROVAL Owner/Applicant Must Read and Sign The foregoing information is complete and correct to the best of my knowledge. I have read and understand the provisions of Chapter 14 Subdivision of Land of the Albemarle County Code,and the Design Manual,and am consenting to all correspondence from Albemarle County be in any of the following forms in writing; by first class mail,by ersonal delivery, by fax or, by email. ` jd Jli./17 Signature of Owner,Contract Purchaser,Agent Date 9,4' albs 434--Zq3- 3719 Print Name Daytime phone number of Signatory FOR OFF CE USE ONLY SUB# Fee Amount Sao •W '0 Date Paid W '§01/1 By who? 011 1`.n21OA `I I a8�{ �. Receipt# Ck# 5382 By: Al Page COUNTY OF ALBEMARLE APPLICATION FOR ROAD PLAN APPROVAL FEES ROAD PLANS FOR PROPOSED SUBDIVISION *If public and private streets are proposed,pay the higher of the two fees(private street) 8 copies of the road plan are required for all submittals Public Street Fees Private Street Fees l For each review of a submitted plan,including re- ❑ Authorization of one or more private streets within views of revisions after plan approval=$269 a subdivision filed separately from a subdivision appli- cation=$720 ❑ For each review of a submitted plan,including re- views of revisions after plan approval =$430 VARIATIONS OR EXCEPTIONS BEFORE APPROVAL OF A PRELIMINARY PLAT ❑ Variation to or exception from street interconnection requirements=$581 U Variation to or exception from one or more street standards=$581 ❑ Variation to or exception from curb and/or gutter requirements=$581 AFTER PRELIMINARY PLAT APPROVAL AND BEFORE FINAL SUBDIVISION PLAT APPROVAL ❑ Variation to or exception from any requirement of Chapter 14 for which a variation to or exception from is au- thorized after approval of a preliminary plat and before approval of a final plat=$892.00. Attach written justifica- tion AFTER FINAL PLAT APPROVAL ❑ Variation to or exception from any requirement of Chapter 14 for which a variation to or exception from is au- thorized after approval of a final plat=$892.00. Attach written justification SURETYBONDING If required to construct a street,the subdivider shall pay to the county a fee equal to the cost of the inspection of the con- struction of any such street.These fees shall be paid prior to completion of all necessary inspections and shall be deemed a part of the cost of construction of the street for purposes of section 14-435(B). The bond process and forms can be found at the document center under bonds.After a plan is approved,a bond estimate request form must be submitted to the Community Development office with the required fee. The owner signatures will be verified for each parcel affected,and estimates will be prepared by the engineering reviewer. A bond amount will be pro- vided to the owner. Bond agreements will be prepared by the county,and when properly completed by the owner,will be reviewed and signed by the County Attorney and County Engineer. Please allow a few weeks for this process. Albemarle Cr In Community Development Department Voice a(434)296-5832 Fax:(4Road Charlottesville, 34)972-44126 11 Planning Application PARCEL/ OWNER INFORMATION TMP 078E0- -t - Owner(s): FONTANA LAND TRUST;A N NICHOLS TRUSTEE Application# SUB2131 700102 PROPERTY INFORMATION Legal Description I ANA RESIDUE A&B Magisterial Dist.lRivanna Land Use Primary Forest mom.... Current AFD 'Not in A/F District E Current Zoning Primary FRAS Residential JD APPLICATION INFORMATION Street Address Entered By Application Type !Subdivision Mat Ju Martin cp 613012017 Project Hyland Park Road Plans Received Date 06/30/17 Received Date Final Submittal Date 07/10/17 Total Fees 1161 Closing File Date Submittal Date Final Total Paid 1161 Revision Number Comments Legal Ad SUB APPLICATION(s) Type Sub Apaiotio Comment New Public Us+e ReadPlan I 07/10/17 APPLICANT /CONTACT INFORMATION ContactType Name ess CityState Zip Phone PhoneCeli owooniAppriutot FONTANA LAND TRU-St A M NICHOLS i P 0 BOX 143 MARYSVILLE CA i 95901- P' '+Y Czmtset SCOTT COLLINS-COLLINS ENGINEERING 200 GARRETT ST.,STE.K CHARLOTTESVILL 22902 4342933719 Signature of Contractor or Authorized Agent Date Page 1 COUNTY OF ALBEMARLE APPLICATION FOR ROAD PLAN APPROVAL Is this an amendment to an approved plan? Yes E No Bl Is this a revision or resubmission for review?Yes❑ NoVJ County File Number: (to be provided by County for new applications) 8 Copies of the Plan to be submitted and distributed by the County as follows: 2 Copies to County Engineering 1 Copy to Albemarle Fire and Rescue 1 Copy to Planning for Street Trees and other landscaping review 2 Copies to Albemarle County Service Authority 2 Copies to Virginia Department of Transportation Have you submitted plans separately to any agencies listed above?Yes NI No ❑ List Agencies: ACSA Project Name fhl ( Pik Tax map and parcels 1 g F`A Zoning 4 Physical Street Address(if assigned): OFT or Foifivoet bYl ✓t% Applicant COLLINS ENGINEERING Street Address 200 GARRETT STREET, SUITE K City CHARLOTTESVILLE State VA Zip Code 22902 Phone Number 434-293-3719 Email scott@collins-engineering.com Owner of Record (k11 (Md ppyp LIC Street Address 45c Sear .d Et S E, SIS.- -e zit-0 City C i t w t c# S V t Ile,,/ State VA Zip Code 22`f 0 2 4-31FPhone Number -21/S—i 4"�///767 Email Z'1#' n Ye r6eI6t V arm Contact (who should we contact about this project):SCOTT COLLINS-COLLINS ENGINEERING Street Address 200 GARRETT STREET, SUITE K City CHARLOTTESVILLE State VA Zip Code 22902 Phone Number 434-293-3719 Email scott@collins-engineering.com County of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434)972-4126 Paget COUNTY OF ALBEMARLE APPLICATION FOR ROAD PLAN APPROVAL Owner/Applicant Must Read and Sign The foregoing information is complete and correct to the best of my knowledge. I have read and understand the provisions of Chapter 14 Subdivision of Land of the Albemarle County Code, and the Design Manual,and am consenting to all correspondence from Albemarle County be in any of the following forms in writing; by first class mail, by personal delivery, by fax or, by email. .J 115v17 Signature of Owner, Contract Purchaser,Agent Date S'A- ;/1 44¢-2-i3--51/' Print Name Daytime phone number of Signatory FOR OF ICE USE ONLY SUB# �(( O• {02i Fee Amount$ li I(.0 � 'Datt�e Paid (p)36)r7- By who t/C(be Receipt# )[(\j Ck# I (( J By: 3 U -- '\rd Page 3 COUNTY OF ALBEMARLE APPLICATION FOR ROAD PLAN APPROVAL FEES ROAD PLANS FOR PROPOSED SUBDIVISION *If public and private streets are proposed,pay the higher of the two fees(private street) 8 copies of the road plan are required for all submittals Public Street Fees Private Street Fees For each review of a submitted plan,including re- ❑ Authorization of one or more private streets within views of revisions after plan approval=$269 a subdivision filed separately from a subdivision appli- cation=$720 ❑ For each review of a submitted plan,including re- views of revisions after plan approval =$430 VARIATIONS OR EXCEPTIONS BEFORE APPROVAL OF A PRELIMINARY PLAT ❑ Variation to or exception from street interconnection requirements=$581 ❑ Variation to or exception from one or more street standards=$581 U Variation to or exception from curb and/or gutter requirements=$581 AFTER PRELIMINARY PLAT APPROVAL AND BEFORE FINAL SUBDIVISION PLAT APPROVAL )4 Variation to or exception from any requirement of Chapter 14 for which a variation to or exception from is au- thorized after approval of a preliminary plat and before approval of a final plat =$892.00. Attach written justifica- tion AFTER FINAL PLAT APPROVAL U Variation to or exception from any requirement of Chapter 14 for which a variation to or exception from is au- thorized after approval of a final plat=$892.00. Attach written justification SURETYBONDING If required to construct a street,the subdivider shall pay to the county a fee equal to the cost of the inspection of the con- struction of any such street. These fees shall be paid prior to completion of all necessary inspections and shall be deemed a part of the cost of construction of the street for purposes of section 14-435(B). The bond process and forms can be found at the document center under bonds.After a plan is approved,a bond estimate request form must be submitted to the Community Development office with the required fee. The owner signatures will be verified for each parcel affected,and estimates will be prepared by the engineering reviewer. A bond amount will be pro- vided to the owner. Bond agreements will be prepared by the county,and when properly completed by the owner,will be reviewed and signed by the County Attorney and County Engineer. Please allow a few weeks for this process. NIS Page COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST A road or street plan is an engineered construction plan for a public or private road or alley. It also contains necessary infrastructure for the road, like drainage inlets,pipes, ditches, culverts, residential and commercial entrances, slopes, retaining walls, signs,pavement markings and any other items necessary for the road. A road plan must be a stand-alone document, and titled as a road plan. A road plan is not a site plan, or a stormwater plan, or an erosion control plan. Please do not attach any other plans to the road plan. The exception is when the Albemarle County Service Authority has insisted in some cases that utility plans (water and sewer) be part of the road plans, and this has been permitted. A road plan must contain a title sheet specifically for the road plan, a plan view of the road, a profile of the road, and specific and typical details for the road sections. Please also reference the Design Manual in addition to this checklist. Application information: Li Completed application and fees. No review is provided without applications and fees. Plans containing both public and private roads should pay the higher fee for private roads. Li Copies of federal and state permits for any wetland or stream disturbance. (Army Corps, VDEQ, etc) [18-32.1.2, 14-311] Title information: ❑ Project title. Titles should be appropriate. It should be a road or street plan, not a site plan, subdivision plan, or erosion control plan, etc. LI Professional seal, with original signature and date. [18-32.6.1] Li Content: The road plan must contain, for each road/street/alley, at a minimum 1. a plan view, customarily at 1"=50' or better. 2. a profile view 3. a typical cross-section Plan View: [18-32.6.2, 14-304, Subdivision Ordinance Article IV Division 2, VDOT SSAR] Li Accurate current existing topography at the time of submittal, including all existing site features, and any recent disturbances, all at a legible scale. ❑ Date and source of the topographic information: All topography should be at least visually field verified by the designer within the last year {Aerial topography is often noticeably inaccurate. Disturbances sometimes take place subsequent to the flown date. This can be a particularly recurring problem where early or mass grading plans have occurred previously. In these cases,the topography needs to be updated.} Li WPO buffer limits; 100' from stream or wetland bank, 200' from reservoirs, or floodplain limit if greater [17-600] ❑ Floodplain limits, including l 00yr flood limits for any channel with a drainage area of 50+ acres [18 -32.6.2d, 18-30.3] Cl All existing easements (access, drainage, sight, sanitary easements, etc.) with deed book references, locations and dimensions. Page 5 COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST ❑ All proposed streets included, with right-of-way and street names ❑ Stationing at 50' minimum on all proposed streets, on plan and profile ❑ Street horizontal curve start point,end points and radii labeled, meeting standards ❑ Cul-de-sacs provided on all dead-end streets or alleys (see the Design Manual reference details) LI Street edge of pavement or curb radii labeled at all intersections and turnarounds (see the Design Manual reference details) ❑ Roundabouts designed per VDOT and ASHTO guidelines ❑ Guardrail over any slope steeper than 3:1, wall, or drop-off greater than 4', with start and end sections labeled, and VDOT designations(GR-2, GR-2a, etc.) (see the VDOT Road Design Manual. Guardrail placement is complicated and subject to a lot of judgement and variation. This is a quick rule -of-thumb summary.) LI Pavement markings dimensioned and labeled ❑ Signs for traffic control shown and labeled: speed limit on all streets, stop signs at all intersections ❑ Street name signs at every intersection, typically placed opposite stop signs [should reference County Road Naming and Property Numbering Ordinance and Manual] LI Street tree locations, species and height or caliper(typically to be reviewed by Planning) Grading: ❑ Proposed topography at minimum 2' contour intervals—tied into existing contours, as well as all proposed site features. (Sites with less than 6' of grade change should consider using smaller contour intervals.) ❑ Proposed slopes are all 2:1 (horizontal:vertical) or flatter {Design Manual, section 8} ❑ Proposed slopes steeper than 3:1 have low maintenance (not grass) ground cover specified on the plan {Design Manual, Section 8} ❑ Show existing critical (steep) slopes on plans (See County GIS, Steep Slope Overlay). Existing critical slopes are not disturbed, unless a waiver or exemption has been granted for the disturbance. LI Retaining walls should be accurately shown on plans, reflecting material thickness and batter where such measurements may affect layout. Retaining Wall Plans checklist. Li Any walls supporting roads or necessary infrastructure require engineered plans (not generic manufacturer's details) and computations. {Design Manual, section 8} This will also be required where walls are close to property lines and there is the danger of affecting neighboring property, either during construction, with later failures, or with pedestrian or vehicle safety. These concerns can be alleviate with layout spacing also. In any case,retaining walls will require building permits at construction. Required Easements: [Zoning Ordinance 18-32.7.4, Subdivision Ordinance,Article IV, Div. 4] ❑ All proposed permanent easements, dimensioned and labeled Examples of easements are: • sidewalk easements for sidewalks to be maintained with streets outside right-of-way. It is preferable that sidewalk be inside street right-of-way. • drainage easements for any drainage passing through the site from off-site, or for drainage crossing proposed property lines. • stormwater management easements over all facilities and associated structures and access • interparcel access easements • intersection or entrance sight easements Pages COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST ❑ All drainage easements are a minimum 20' wide. Required width: 10'+(pipe dia. or channel width) +2'+2(depth-5'). The pipe, channel or structure must be within the center third of the easement. {Design Manual, section 6} ❑ No structures or trees within drainage easements {Design Manual, section 6} ❑ Label drainage easements beyond public rights-of-way as 'Private'. A deed of easement for the maintenance of these will be required for approval. Entrances and right-of-way improvements: [per VDOT Secondary Street Acceptance Requirements (SSAR), and VDOT Road and Bridge Standards] ❑ Only approved entrances are shown. Placing entrances on road plans should not be a way of circumventing site plan review of entrance placement or number, or adequate review of traffic, spacing, turn lanes, etc. ❑ All entrances have a VDOT designation [PE-1, CG-9a, etc). In the case of dense residential development, concrete entrance aprons are important to continue drainage on the street side, and to control fine grading of asphalt and sidewalks. LI Commercial entrances do not exceed 4% grade for a distance of 40' from the intersected street, measured anywhere in the entrance [18-4.12.17] ❑ Unobstructed sight distance lines at entrances, more than 10' x speed limit, plus next 5mph increment. For example: sight distance for 25mph design speed limit= 10' x 25 + 30=280'. See VDOT Road Design Manual,App Bl, Sec. 3E ❑ 25' minimum radii on entrances (or per VDOT requirements, typically 25'-35') [per VDOT Access Management Regulations and Standards] ❑ Turn and taper lanes where applicable with lengths and widths labeled (taper at 12:1 with 12' lane widths) Profile View: (applicable only to road or street plans) LI Stationing at 50' minimum on all proposed streets, to match the plan view sheets LI Proposed centerline ❑ Existing ground centerline (Historically, the existing centerline was field surveyed,but this is happening much less with current aerial topography. This may be requested if inaccuracies are noted.) Lit Labeled existing and proposed grade at each 50ft station point ❑ Vertical curves provided at all grade transitions LI Vertical curve start, vertex and end points labeled LI Vertical curve length and K(or stopping sight distance) labeled at each vertex, meeting required design values ❑ Percent grades labeled for all road segments, meeting design values (VDOT Road Design Manual, App. B) ❑ Rural street intersections continue the -2% intersected cross grade for a minimum of 20' from the edge of pavement of the intersected street. A low point is provided off the intersected street for drainage. {policy, following VDOT practice} ❑ Street grade is less than 4% for a minimum of 40' from the edge of pavement of the intersected street. (This grade can be within the first road curve which transitions from the 2% intersected cross grade) {policy, follows ord. for travelways 18-4.12} LI Pipe and utility crossings shown and labeled (ACSA has minimum clearances) Pagel COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST ❑ Cross drain locations shown and labeled with VDOT designations (CD-1,2) at every major cut and fill transition or sag curve ❑ The station of intersections are shown and labeled with the street names LI Grades are a maximum of 6% in turnarounds Li Grades are a maximum of 4%through roundabouts Details and Sections: (reference VDOT Road Design Manual, or Sub. Ord.) ❑ Typical sections for each street, street segment, or alley ❑ Typical sections for sidewalks and trails ❑ Albemarle County general construction notes for streets (reference) Li Traffic generation and distribution summary (ADT's)with road networks ❑ Pavement designs per VDOT guides [2009 VDOT Pavement Design Guide for Subdivision and Secondary Roads in Virginia] ❑ Pavement widths meeting design standards ❑ Pavement crown at 1/4":1' slope ❑ Pavement surface, base, and sub-base thicknesses and materials ❑ Curb and gutter where applicable with VDOT designation(CG-6), and stone base of 6" 21-A or better(CG-2 also acceptable if a gutter is not needed for drainage) LI Shoulder at 1":1' slope or flatter and 4' or greater width for rural sections ❑ Maximum slopes of 2:1 or flatter with guardrail shown where applicable. Li Proposed slopes steeper than 3:1 have low maintenance (not grass) ground cover specified on the plan ❑ Guardrail over all fill slopes and culverts, with 3' additional shoulder, using VDOT designations (GR-2,GR-2A, etc.) Li Right-of-way/easement width, centered on street, meeting design standards ❑ Sidewalk location and widths, minimum 5' width, 4" concrete surface, 4" 21-A stone base with wire/ rebar reinforcement, with underdrains (UD-4, etc)per VDOT standards where applicable ❑ Sidewalks shall not be less than 4 inches thick, except when used in conjunction with roll top curb, in which case the thickness shall be 7 inches. See Section B(1)-4.G Curb and Gutter Designs, Figure 6- Detail Back of Curbs in VDOT Road Design Manual ❑ Planting strip if applicable, 6' minimum width [14-422] ❑ Ditches dimensioned at 3:1 slope from shoulder, 1' depth min., and 4' min. width from shoulder to ditch centerline, for rural sections ❑ Alleys have 12' pavement width,with 14' wide stone base [14-410] Li Transitioning detail (20' minimum) for roll-top curbing in front of any inlets ❑ Typical sections for proposed channels with locations referenced from the plan view sheets Li Sidewalk detail or specification to be a minimum 4" stone base and 4"concrete of 3000psi at 28 days, or stronger. [VDOT App. B, Subdivision Street Design Guide, and 14-422] ❑ Retaining wall details referenced from plan, if detailed plans and comps were not required. This is only really applicable to standard VDOT gravity walls. Walls not affecting the road should not appear on road plans. ❑ Rural section ditches may not be deep enough for 15"diameter culverts within the ditchline if the ditches are only 1' deep. This usually involves moving the ditchline away from the road at driveway locations, which may not be possible in denser development. Ditch and driveway culvert plans will need to accommodate these situations. Page 8 COUNTY OF ALBEMARLE ROAD PLAN CHECKLIST Read and Sign In representing the above referenced firm submitting this road plan for approval,I hereby state that,to the best of my knowledge,the attached road plan contains all information required by this checklist. Signature of person completing checklist Date