Loading...
HomeMy WebLinkAboutSUB201700034 Review Comments Appeal to BOS 2018-06-01County of Albemarle Department of Community Development Memorandum To: Scott Collins From: Matt Wentland Date: 12 May 2017 Subject: Hyland Park Final Grading Plan (SUB 201700034/WPO201700028) Scott, The final grading plan for Hyland Park has been reviewed by Engineering. The following comments will need to be addressed before approval: 1. Show the grading of the trails and include the Class A Type 1 trail standards on the plans. (Proffer 2A) 2. Show the proposed Delphi Lane connection on the plans. (Proffer 2A) 3. Show the relocation and grading of the existing driveway being disturbed by the proposed Delphi Lane connection. (Proffer 2A) 4. Provide a landscape plan satisfying Proffer 4 as part of the final grading plan. (Proffer 4, 18.31.7.9.4) File: WP0201700028 Hyland Park gradin plan Comments 05-12-17.doc COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434)296-5832 April 19, 2017 Scott Collins Collins Engineering 200 Garrett Street, Suite K Charlottesville, VA 22902 RE: SUB2017-34 Hyland Park - Preliminary Subdivision Plat Dear Mr. Collins: The Site Review Committee has reviewed the development proposal referenced above. Initial comments for the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Planning Services Albemarle County Engineering Services Albemarle County Service Authority Virginia Department of Transportation Albemarle County Department of Fire Rescue Albemarle County Building Inspections Albemarle County Information Services (E911) (to be provided once received) Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that will be required to be resolved prior to Final Plat approval. Prior to preliminary plat approval, at a minimum, comments 1— 3 & 22-23 shall be satisfied. Please request a deferral of the preliminary subdivision plat for a period of 6 months to allow the final grading plan to be reviewed and approved. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, Christopher P. Perez Senior Planner COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 04-19-2017 Scott Collins 200 Garrett Street, Suite K Charlottesville VA 22902 RE: SUB2017-34 Hyland Park - Preliminary Subdivision Plat Dear Sir: Department of Community Development has reviewed the above referenced subdivision plat (dated 3-6- 17) against ZMA2004-18 & ZMA 2011-1 and it's applicable Proffers, Application Plan, and County Codes and Ordinances. Comments are provided below; however, additional comments or conditions may be added or eliminated based on further review.): [Each comment is preceded by the applicable reference] Prior to preliminary plat approval, at a minimum, comments 1— 3 & 22-23 shall be satisfied. 1. [Comment] The public notification fee of $215 was not paid prior to the SRC meeting. Please pay the fee prior to any further review/action of the plat. 2. [ZMA2004-18, (Proffer #2)] Proffer 2 states in part: "The Final Grading Plan shall be approved by the County Engineer prior to the approval of the first preliminary subdivision plat." A Final Grading Plan has not been approved for the current proposal; as such, the preliminary plat shall not be approved, nor approved with conditions until the final grading plan is approved. Any changes from the review of the final grading plan will need to be reflected on the preliminary plat through a resubmittal. The applicant has submitted WP02017-28, which contains a final grading plan. Please request a deferral of the preliminary subdivision plat for a period of 6 months to allow the final grading plan to be reviewed and approved prior to staff taking an action on this preliminary subdivision plat (SUB2017-34). [ZMA2004-18, Proffer 4] Trees. Each residential lot shall have a minimum of five (5) trees. These trees can either be new plantings or preserved existing trees (see proffer for tree standards). Provide a landscape plan in WP02017-28/final grading plan and provide enough information for staff to verify the proffer requirement is met. These plantings shall be bonded with the WPO plan. The five trees to be counted on each lot shall be marked in the field for inspection purposes. On the final plat provide the following note: `Each residential lot shall contain a minimum offive (5) trees. The owner shall not request a certificate of occupancy until a final zoning inspection is performed and all required trees are in place. " 4. [14-302(A)(15), ZMA2004-18 (Proffer #1/Application Plan)] The noncontiguous portion of TMP 78E -A, listed on the application plan as Lot "A" shall be combined with TMP 78E-118 to create one large lot. Prior to or with the first final plat for Fontana 4C these lots shall be combined. 114-302(B)8, 4.191 Yards. The front setbacks for Lots 23, 29, 30, 31 are incorrect. The maximum front setback is 25 feet. Revise. If the maximum setback cannot be achieved because of the proposed lot widths, modify the lot widths by relocating one of the lots. 6. [14-302(B)8, 4.19] Non -infill Setbacks. Revise the setbacks note on sheet 1 to label the setbacks as "Non -infill Setbacks ". 7. [14-401,14-203.1(B)] Double frontage lots. Double frontage lots for single family detached residential uses are prohibited. The double frontage lots are: Lots 31, 32, and 34. Either redesign these lots to have a minimum of twenty (20) feet of common area between the rear of the lot and the second street or an exception under 14-203.1(B) is needed prior to final plat approval. 8. [30.7, 30.7.41 Steep Slopes. The preliminary plat depicts unauthorized disturbance (grading and buildable areas) on preserved slopes for Lots 9, 10, and 28. Disturbance of these slopes is not permitted. Revise plat to not disturb these slopes. 9. [14-302(B)(5)] Zoning Classification. Revise the zoning to also include preserved and managed slopes. Preserved slopes shall be labeled & depicted on the final plat. 10. [14-302(A)4, 14-302(A)14, ZMA2004-18, ZMA2011-1, Proffer 101 Pedestrian Paths. Continue the proposed pedestrian trail adjacent to Lot 20 through Open Space B to connect with the existing trail easement behind the adjacent parcel TMP 78E-101. 11. [ZMA2004-18, Proffer 5] Pedestrian Paths. Add the following note to the final plat: "The Owner shall not request that the County issue the ninth (9`h) building permit until the paths have been completed to the satisfaction of the County Engineer. " 12. [ZMA2004-18, Proffer 9)] Add the following note to the final plat: `All structures shall be constructed using medium shaded earth -tone colors for fagade treatments of the buildings and dark, non -reflective material for roofs. " Also, assure this standard is provided in the covenants and restrictions document. 13. [14-303(D)] Acreage. The acreage of the site utilized throughout the plat is not consistent. Sheet 1 utilizes 15.21 acres and sheet 2 utilizes 16.38 acres. On the final plat assure the acreage of the parcel is consistent throughout. 14. [14-303(D), 18-15.3] Acreage. Provide the following note under the density: "Standard Level Cluster Development — No Minimum Lot Size. " 15. [14-422] Sidewalks. Depict and label the existing sidewalks on both sides of Fontana Drive. 16. [Comment] For all public right-of-ways being platted provide the following note: "Hereby dedicated to the County for public use". 17. [Comment] On sheet 5, revise the cutsheets for Glenleigh Road, Belluno Lane, Belluno Court and Delphi Lane to assure all labels are congruent w/ regard their being "public roads" and the road widths. 18. [14-302(A)14, 14-303(G)] Dedication of open space. Provide the following note: "Open Space is hereby dedicated to the HOA. " 19. [14-317] Instrument evidencing maintenance of certain improvements. Prior to final plat approval an instrument evidencing maintenance of the Open Space, Required plantings associated with proffer 4, and Trail maintenance docs will need to be approved by the County Attorney. Submit the draft documents to Planning staff for a cursory review and then I will forward them to the County Attorney for review/ approval. 20. [14-311] Infrastructure Improvement Plans. Road Plan and WPO Plan must be approved, all required improvements must be built or bonded, and all required Deeds and Declarations must be reviewed and approved prior to final plat approval. 21. [14-303] Contents of final plat. A plat meeting all the requirements for final subdivision plats per the subdivision ordinance. Additional Discussion/Comments on the Cascadia/Fontana Connector (Delphi Lane) 22. 114-422(E), 14-422(F), 14-410(I)] Cascadia/Fontana Connector (Delphi Lane). The requirements for sidewalks [14-422(E)], planting strips [14-422(F)], and the curb and gutter [14-410(I)] may be considered for modification by the Planning Commission upon a complete request for these waivers. If the applicant would like to seek these waivers, please make the request with the preliminary plat. When making the request(s) assure the road plan provides two designs for Delphi Lane: A) a public road without any waivers considered in the design, which means it provides sidewalks, planting strips, and curb and gutter on both sides. This is being required to assure the ultimate width of the roadway is reserved for dedicated to public use in the correct location. and B) a public road with the waivers considered in the design, which means it does not provide sidewalks, planting strips, and curb and gutter. If the Commission approves all the waivers discussed above the applicant will be required to reserve for dedication upon demand of the County the full width of the public road as described in option A above, and will only be required to build the road taking advantage of the waivers as described in option B above. Staff reviewers involved in processing/consideration of the request: Planning, Engineering, Fire & Rescue, and VDOT. 23. [14-409(D)] Variation or exception by agent of extension requirement. If the applicant of Hyland Park decides they do not want to build the connection to the property line then the applicant needs to apply for the variation of the extension requirements as provided for in Section 14-409(D) with the preliminary plat. If approved this would allow the applicant to merely design, plat the R/W dedication, and bond the connection. Engineering — Mathew Wentland 1. The Final Grading Plan (submitted as part of WPO201700028) will need to be approved prior to Preliminary Plat approval. The conditions of Proffer #2 will be reviewed with the Final Grading Plan and any changes from that review will need to be reflected on the Preliminary Plat. 2. Provide a detail for the Class A Type 1 pedestrian paths. Also show the connection of the proposed path through Lot 20 to the existing trail system. 3. Provide an easement around the outlet pipes for the basins. It also appears an easement will be needed for the pipe located at the corner of Lot 26. 4. A separate road plan and application will be required. The road plan will need to be approved prior to issuance of a grading permit and any grading changes due to road plan comments may require an amendment to the Final Grading Plan. ACSA — Alex Morrison • Water and Sewer Construction Plan Review by the ACSA is required. Submit 3 copies of the final plan to the ACSA, ATTN: Michael Vieira, PE, along with water and sewer data sheets to start the review. • Correctly show RWSA transmission water main adjacent to the rear of lots 20-22. • Lots 20-34 will require private PRV's because they are on the Ashcroft Lower pressure band. • Label all water fittings, valves, tapping sleeves, etc. • The sanitary sewer tie in near lot 19 is not currently the end of the public sewer. Correctly show the existing sewer and add notes to abandon the sewer main and manhole. VDOT — Justin Deel/Adam Moore 1. Information on the typical sections does not match up with information on the plans. The sections say private ROW while the plans say public. The curb to curb dimensions do not add up. It is not clear why a section for Delphi Lane is provided. 2. In regards to the proposed 32' radius cul-de-sac, the minimum radius of 45' can only be reduced when specifically approved by the County in consultation with emergency services. See Appendix B(1) page B(1)-25. 3. Note that the subdivision/road plan must show conformance with the VDOT Road Design Manual Appendices B(1) and F, as well as any other applicable standards, regulations or other requirements. Fire and Rescue - Robbie Gilmer Based on plans dated 2/13/17. (Robbie has been made aware that he reviewed the wrong version of the plat, modified review comments may be forthcoming). 1. Streets 29' fc/fc shall be marked no parking on one side. Sign spacing shall be 150' on center. 2. Fire flow test required before final approval. Please attach a copy to the final plans. 3. Relocate hydrants on Glenleigh Road. One hydrant located at the intersection of Fontana Drive and Glenleigh Road, second hydrant shall be no more than 500' ft the first hydrant. 4. Relocate hydrant on Belluno Lane to the open space B near lot 20. Inspections — Keith Huckstep No objections E911— Derek Bedarf Comments pending. To be forwarded once received. Please contact Christopher P. Perez in the Planning Division by using cperez(kalbemarle.org or 434-296- 5832 ext.3443 for further information. COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper Virginia 22701 Charles A. Kilpatrick, P.E. Commissioner April 7, 2017 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Christopher Perez Re: Hyland Park — Preliminary Plat SUB -2017-00034 Review #2 Dear Mr. Perez: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Collins Engineering, dated 6 March 2017, and offers the following comments: 1. Information on the typical sections does not match up with information on the plans. The sections say private ROW while the plans say public. The curb to curb dimensions do not add up. It is not clear why a section for Delphi Lane is provided. 2. In regards to the proposed 32' radius cul-de-sac, the minimum radius of 45' can only be reduced when specifically approved by the County in consultation with emergency services. See Appendix B(1) page B(1)-25. 3. Note that the subdivision/road plan must show conformance with the VDOT Road Design Manual Appendices B(1) and F, as well as any other applicable standards, regulations or other requirements. If further information is desired, please contact Justin Deel at 434-422-9894. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the Charlottesville Residency Transportation and Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, /�w LX.-I Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency VirginiaDOT.org WE KEEP VIRGINIA MOVING