Loading...
HomeMy WebLinkAboutSDP201700027 Checklist Initial Site Plan 2015-06-10 Initial Site Plan "� Checklist Project Name: O T ) (alk. Pk..f. Firm: D1- rsei.0 &CC tla This checklist must be completed,signed_and submitted with the application. The information contained in this checklist reflects the contents of the Section 32 of Chapter 18 of the Code of the County of Albemarle also known as the Site Plan Ordinance as of January 1, 2013. The applicant is responsible for insurinj that no revisions to the Ordinance have occurred since preparation of this document Plans which lack the information required by this checklist shall be deemed to be incomplete and shall be depied by the agent with ten (10)calendar days after the applicable submittal deadline[Section 32.4.21. An Initial Site Plan shall contain the following: .[32.5.1 a]Number of copies. ❑ Sixteen(16)clearly legible copies in blue or black ink of the plan shall be submitted. 1[32.5.2 lb] Scale and size. ❑ The plan shall be prepared to the scale of one(1)inch equals twenty(20)feet or to another scale approved by the. agent in a particular case.No sheet shall exceed forty-two(42)inches by thirty-six(36)inches in size. ❑ The plan may be prepared on one(1)or more sheets. If prepared on more than one(1)sheet,match lines shall clearly indicate where the several sheets join. ❑ The top of the sheet shall be approximately either north or east. [32.5.1 c1 Dimensions. ❑ The plan shall be dimensioned to at least the following standards for accuracy: ❑ Boundary, setback and zoning lines: One foot in one thousand(1:1,000)feet. ❑ Existing contours: One-half(1/2)of the contour interval required in section 32.5.2(d). ❑ Proposed contours: Within five(5)feet horizontally and vertically. ❑ Existing structures,utilities and other topographic features: Within five(5)feet. ❑ Proposed structures,roads,parking lots and other improvements: Within five(5) feet. ❑ [32.5.2 a]General information. ❑ The name of the development, ❑ names of the owner,/ ❑ developer and individual who prepared the plan; Cl tax map and parcel number; ❑ boundary dimensions; ❑ zoning district; 00 descriptions of all proffers, special use permits and conditions thereof, special exceptions and conditions thereof,variances and conditions thereof, application plans,codes of development and bonus factors applicable to the site; C)❑ magisterial district; ❑ county and state;v ❑ north point; ❑ scale; one datum reference for elevation(where section 30.3, flood hazard overlay district, is involved,United States Geological Survey vertical datum shall be shown and/or correlated to plan topography); ✓ ❑ the source of the topography;./ ❑ departing lot lines;✓ ❑ minimum setback lines,yard and building separation requirements; ✓ ❑ the source of the survey; ❑ sheet number and total number of sheets; and ' ❑ the names of the owners,zoning district,tax map and parcel numbers and present uses of abutting parcels.,/ County of Albemarle Department of Community Development 401 Mclntire Road Charlottesville,VA 22902 Voice:(434)296-5832 Fax: (434)972-4126 REVISED 06/10/2015 Page 1 of 4 Couof Albemarle-Initial Site Plan Checklist `O [32.5.2 jJ Existing sewer and drainage facilities. ❑ The location and size of ❑ existing water and sewer facilities and easements, ❑ the storm drainage system, ❑ drainage channels,and ❑ drainage easements. .XJ [32.5.2 kJ Proposed sewer and drainage facilities. ❑ The proposed conceptual layout for ❑ water and sewer facilities and ❑ the storm drainage system, indicating the direction of flow in all pipes and watercourses with arrows. [32.5.2 I] Existing and proposed utilities. ❑ The location of other existing and proposed utilities and utility easements, ❑ including existing telephone, ❑ cable, ❑ electric and / ❑ gas easements. ✓O [32.5.2 m]Ingress and egress. ❑ The location of existing and proposed ingress to and egress from the property, ❑- Show the distance to the centerline of the nearest existing street intersection from the proposed ingress and egress. ❑ [32.5.2 n] Existing and proposed improvements. ❑ The location and dimensions of all existing and proposed improvements including ❑ buildings(maximum footprint and height)and other structures; ❑ walkways; ❑ fences; ❑ walls; ❑ trash containers; 'j❑ outdoor lighting; ❑ landscaped areas and open space; ❑ recreational areas and facilities; ❑ parking lots and other paved areas; ❑ loading and service areas; ❑ signs; and ❑ the proposed paving material types for all walks,parking lots and driveways. ❑ [32.5.2 of Areas to be dedicated or reserved. ❑ All areas intended to be dedicated or reserved for public use under sections 32.7.1.1, 32.7.1.2 and 32.7.1.3,and ❑ shall include a note on the plan stating that the land is to be dedicated or reserved for public use. ❑ [32.5.2 p1 Landscape plan. ❑ A landscape plan that complies with section 32.7.9, if it is required to be submitted with the initial site plan. ❑ [32.5.2 qJ Traffic generation figures. ❑ If deemed appropriate by the agent due to the intensity of the development, estimated traffic generation figures for the site based on current Virginia Department of Transportation rates; ❑ indicate the estimated number of vehicles per day and the direction of travel for all connections from the site to a public street. ❑ [32.5.2 rJ Symbols and abbreviations. ❑ A legend showing all symbols and abbreviations used on the plan. REVISED 06/10/2015 Page 3 of 4 Final site Development Plan ? Checklist Project Name: Firm: This checklist must be completed,signed and submitted with the application. The information contained in this checklist reflects the contents of the Section 32 of Chapter 18 of the Code of the County of Albemarle also known as the Site Plan Ordinance as of January 1,2013. The applicant is responsible for insuring that no revisions to the Ordinance have occurred since preparation of this document. This final site plan has: ❑ an initial site plan that was approved for the development and it remains valid; SDP-20 - ❑ satisfied all of the requirements of section 32.6 below;and ❑ satisfied all of the conditions delineated in the letter provided under section 32.4.2.5(c)required to be satisfied prior to submitting the final site plan. ❑ Authorized preparer. ❑ The plan,and any amendments to a plan,is prepared and sealed,signed and dated by one of the following ❑ An architect licensed to practice in the Commonwealth of Virginia. ❑ A professional engineer licensed to practice in the Commonwealth of Virginia. ❑ A land surveyor licensed to practice in the Commonwealth of Virginia. ❑ A certified landscape architect licensed to practice in the Commonwealth of Virginia. ❑ Number of copies when first submitted. ❑ Provide the number of copies as directed in the Initial Site Plan approval letter ❑ One(1)reduced copy of the plan no larger than eleven(11)by seventeen(17)inches in size. ❑ Scale and size. ❑ The plan is prepared to the scale of one(1)inch equals twenty(20)feet or larger,or to another scale approved by the agent in a particular case. ❑ Other scale approved -one(1)inch equals ( )feet,by ❑ No sheet exceeds forty-two(42)inches by thirty-six(36)inches in size. ❑ The plan IS prepared on one(1)sheet.OR ❑ The plan IS prepared on more than one(1)sheet and match lines clearly indicate where the several sheets join. ❑ The top of each sheet is approximately ❑ North or ❑ East ❑ Dimensions. The plan is dimensioned to at least the following standards for accuracy: ❑ Boundary,setback and zoning lines:Within one one-hundredth(0.01)of a foot. ❑ Existing contours:Within one-half(1/2)of the contour interval required in section 32.6.2(c). ❑ Proposed contours:Within one(1)foot horizontally and vertically. ❑ Spot elevations:Within one-tenth(0.10)of a foot. ❑ Existing critical structures including utilities and other topographic features:Within two(2) feet, provided that for critical structures,which include,but are not limited to,gas lines,other utilities,pipes, conduits,walls and buildings to be preserved,within one-tenth(0.10)of a foot. ❑ Proposed structures,roads,parking lots and other improvements:Within one one-hundredth(0.01)of a foot. REVISED 06/10/2015 Page 1 of 4 ( marle County-Final Site Plan Checklist ❑ Street sections. ❑ Typical street sections together with specific street sections where street cut or fill is five(5)feet or greater; ❑ centerline curve data; ❑ radius of curb returns or edge of pavement; ❑ location,type and size of proposed ingress to and egress from the site together with culvert size; ❑ symmetrical transition of pavement at intersection with existing street; ❑ the edge of street surface or face of curb for full length of proposed street; ❑ when proposed streets intersect with or adjoin existing streets or travelways,both edges of existing pavement or travelway together with curb and gutter indicated for a minimum of one hundred(100) feet or the length of connection,whichever is the greater distance. ❑ Public facilities and utilities. ❑ All public facilities,utility and drainage easements outside the right-of-way of public streets,provided that new easements may be generally shown and accurately dedicated by separate plat. ❑ All water and sewer facilities to be dedicated to public use and the easements for those facilities and shall be identified by a statement that the facilities are to be dedicated to the Albemarle County Service Authority. ❑ Signature panel. ❑ Signature panel for signature by each member of the site review committee. ❑ Parking and loading areas. ❑ For all parking and loading areas, indicate the ❑ size, ❑ angle of stalls, ❑ width of aisles and specific number of spaces required and provided, and ❑ method of computation. Indicate type of surfacing for all paved or gravel areas. ❑ Landscape plan. ❑ A landscape plan that complies with section 32.7.9 ❑ Outdoor lighting. ❑ Outdoor lighting information including ❑ a photometric plan with ❑ location,description,and photograph or diagram of each type of outdoor luminaire. ❑ Recreational facilities. ❑ Specifications for recreational facilities. In addition to the items required by the ordinance, Albemarle County Engineer,the Virginia Department of Transportation,the Albemarle County Service Authority, and the Thomas Jefferson Health District require these items on plans submitted for final site plan approval. Plans will not be rejected if these items are not present, but they are required for approval. These items are provided in an effort to communicate all final site plan comments. ❑ 1. Reference the benchmarks used for surveys. (Albemarle County Engineering Policy) ❑ 2. Indicate the available sight distance for entrances and left turn lanes. (Albemarle County Engineering Policy) ❑ 3. Label the maximum height of all retaining walls. (Albemarle County Engineering Policy) ❑ 4. Provide copies of off-site easements,or letters of intent to grant them from off-site property owners. (Albemarle County Engineering Policy) REVISED 06/10/2015 Page 3 of 4