Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SDP201600062 Action Letter 2018-07-02
COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 July 2, 2018 Justin Shimp 201 E Main Street, Suite M Charlottesville, VA 22902 RE: Letter of Revision (LOR) # 2 for SDP2016-62 Tax Map Parcel 04500-00-00-112BO Mr. Shimp, This letter is in response to the attached LOR request letter dated June 26, 2018. The Department of Community Development hereby grants approval of a LOR for the improvements described in the letter and shown on the attached exhibits dated 6-28-18. The flag pole shall only fly qualifying flags under Section 4.17.6(C) of County Code. This is the second (2nd) LOR for this site. Three (3) LORs are allowed, after which all required changes must be submitted as a site plan amendment. Sincerely, Christopher P. Perez Senior Planner Attachments: LOR Application/Letter of Request Exhibits pgs 1-3 Lighting Cutsheet Copy: SDP2016-62 PROJECT MANAGEMENT SHIMCIVIL ENGINEERING LAND PLANNING ENGINEERING June 26, 2018 Mr. Chris Perez Albemarle County Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Regarding: SDP 2016-62 Better Living Berkmar — LOR #2 Dear Chris, Attached you will find our LOR plans to revise several site plan items for Better Living Berkmar. These small revisions are described for each respective plan sheet which you will find attached. 1. Added additional HVAC units to the side of the building. Locations of the flag pole and associated lighting fixture have been added. 2. Replaced transformer with HVAC units. Shifted the fence slightly to allow full parking dimensions. Updated location of gate. Updated Building B dimensions. 2 Spaces are now 60` angled spaces. 3. Loading zone is separated by a slope and is now 2 smaller zones. Shed D has been revised. If you have any questions or concerns about these revisions please feel free to call Justin at (434) 299-9842 and we can discuss any questions that you may have in further detail. Best Regards, Keane Rucker, E.I.T. Shimp Engineering, P.C. Page 1 of 1 Application for Letter of Revision 9 Letter of Revision = $108 This application may require additional review by the Fire Marshal. Fees in addition to those shown on this application may be required as required by the Fire Prevention Code Fee Schedule. A copy of the schedule is available from the Fire Marshal. Final Site Plan Name and Number: Contact (who should we contact about this project)Iasi 1'1 slll� Street Address q I Z C: 14', h .Si' City C�kA%b �6-,5 VdIC State VA Zip Conde ZZ4yz Phone Number "1 3 � " Z e1 I - q �i Email �1V f 4i �A !w S11 Owner of Record b Proe eif; c s Lc - Street Address P,o• JoY 76 Z 7 City Gh*&/-1Okw-,s V/ %le, State VA Zip Code Z Z /06 Phone Number Applicant. Street Address. City Phone Number SUBMITTAL REQUIREMENTS: C-0 LYE The appropriate fee, �i The site plan number that the change applies to, d A request letter describing the proposed changes from the owner or authorized agent, 4 copies of the plan that shows the proposed changes, Code Changes must be shown on the sheet or sheets from the approved final site plan, or on an 11'XIT' copy of that portion of the approved final site pla Owner/Applicant Must Read and Sign I hereby c if t the information provided on this application and accompanying information is accurate, true and correct to the best of rn kn le a ief. Signature o r, gent Date DI154-2a9• gs"12 Print Name Daytime phone number of Signatory FOR OFFICE USE ONLY LOR # Fee Amount $ Date Paid &' 1 v ` By who? 1 y �I Q l��c pt # 4_Ck# 4 B}� County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Voice: (434) 296-5832 Fax: (434) 972-4126 REVISED 4/23/2018 Page 1 of 1 TER 2� STATE ROUTE 1403 / BERKMAR DR VEPUBLIC R/W PAVED / 35 MPH SPEED LIMIT - c.,j GUTTER�- O w O 0) O ro O = N D I m r 0 = w = <V) F� m D N N �o 0 N c- c N A z ®u �Z 0m I Z p � a it m m N A N Z v 0 I n N K O 11 I � F I 1 III I I III I I I I I I I I I II III 11 IiII I I III I I I I I I I I I II I I 1 I l l l 1 I I 1 l l 11 11 11 II II I n I 1 I f 0 Co 1 F— O D O It f I W • i. / I I •/* c I _ I � D I I I I Y3o 'DOD G') W I ' •: •.• . • . ' t' � o / I I I I _ \ I I I �: I to = m I �� W En umi D D � w I � i O o� I D m W O / W / P m I I P�/ /IN II � W I oITl W� o oI—"0 oPco�0C 33 9'Xis' SPACp (APPROVED NU BER:v 33 SPACES) / / 00 L / Dml / I 1G) ZNfW Dv \ / / O Dh C D �I Ln I 9 // / / D O // I � 2 N rAri p � / I °; I / / / l� J mOn / CO / �0' o oi >Z//p/ C I Om 0�o �� J°o x Do n ) \ rTI / I / _ /� W I/ cA Io m z r' o W m> = Z v 000 fTl lml O, Z J+1 2-un N \�\\ �nN O K O 1 ZNP!' W v, / An i /I�,�' / I / / / I' ► s�� CA z T m K D I oJ�o / O / / / o / A x / _: C N in z � m I m„ z �u z't m a z � O N K O �z/moo -Q4rn r / N ��\ IMo CD 00 Z N " O z l \ I CY) o ;o m N o o I--, = o FTl m D N O 0 ORAGE--S ED STOAGE SiiED F / v o rl CA Project Name: BETTER LIVING Old Dominion Notes: UghHng Associates fie Ughmwise in v/rg/n/o I r-)- design, performance PHILIPS STONCO LYTEPRO LED LARGE FLOODLIGHT 10SW LPF4 The Philips Stonco LytePro LED Large Floodlight allows precision and flexibility in a compact design. The LPF4 features state-of-the-art long -life LED technology and is ideal for landscapes, accenting signage or displays, facades, and many other lighting applications. T LYTEPRO LED LARGE FLOODLIGHT 105W LPF4 Project: Location- Catalog No: Fixture Type: M. fg: M`Lamps: Rty: Notes: Ordering guide' example: LPF4-C-4K-FL-S-FI-PCB-I-BZ Series / # of COBS LPF4 — Drive Current E — ColorDistribution Temperature O — a — Mounting = — Options — Voltage F__1 — Finish O LPF4 LytePro LED Large Floodlight 105W C 700 mA 4K 4000K' FL Flood S Slipfitter 2-3/8" O.D. F14 Single Fusing F21 Double Fusing F3' Double Fusing, Canada PCB' Photocontrol DM25." Dynadimmer 1 120V 2 208V 3 240V 4 277V 6 347V BZ Textured Dark Bronze SK 5000K' T Trunnion WH Textured White DGY Textured Dark Gray 8 120-277V Accessories — Ordering Guide (mustbeordered separately) Catalog # Description LPF4WG1 -" Wire Guard LPF4SG'a•" Stone Guard Footnotes: 1. MTO configurations are assembled in the USA 2. COB denotes Chip On Board LED platform. 3. Both 4K and SK options have a minimum 80 CRI. 4. 'F1' for 120, 277, 347V. 5. 'F2' for 208.240V. 6. TY for 208, 240V Canadian double pull. 7. Specify, voltage. 'PCB' not available with V universal voltage option. 8. 'DM25' only available 120-277V and dims to 25%for 6 hours. 9. Dynadimmer is suitable for use from -30°C to 40° temperature ambient only Stocked Luminaires — Ordering Guide`,",t4'" Catalog # Description Master Pack, QTY UPC Code STKLPF4S-8 LPF4, Slipfitter Mount, 120-277V 1 786034956956 STKLPF4T-8 LPF4, Trunnion Mount, 120-277V 1 786034956963 10. Limited quantities stocked in our Carrollton RDC 11. Contact factory for availabilay of large order quantities 12, All stock products are'BZ'Textured Dark Bronze,'41(' Neutral White and'FL' Flood Optics. 13. Stock LPF products ship out of our Carrollton Distribution facility within 2-days of receipt of order. 14. Always consult factory for current inventory levels. Larger quantities may be converted to MTO if necessary 15. LPF4 is provided in a standard shipper box PHILIPS stenco LytePro—LPF4 08/14 page 1 of 3 YGJVI �f/LI V�1 , Lr 1 T-V'T!\-Vr-V-V�YL Project Name: BETTER LIVING Old Dominion Notes: lighting Associates The L4h8louse In Vlrginic Features • LPF4 flood distribution delivers 9,191 lumens at 105W, with an efficacy of 88 lumens per watt • LPF4 spot distribution delivers 8,442 lumens at 105W, with an efficacy of 79 lumens per watt • Effectively replaces equivalent 25OW HID at minimum • 4000K neutral white is standard, 5000K cool white is optional, minimum 80 CRI • DLC certified optics provide excellent uniformity ideal for general facade, target and landscape illumination • Fixtures are IP66 rated and suitable for use in ambients from -40°C to 40"C • Rated system life of 80K hours for the driver and LED (>L,) at ambients up to 30°C • 5-year limited warranty, see philips.com/warranties for details • LPF4 stocked in dark bronze, slipfitter and trunnion mount, flood optic, 120-277V and 4000K Neutral White for quick 2-day shipment • Additional made to order versions available that are assembled in the USA, consult factory for current lead time Performance Specifications T LYTEPRO LED LARGE FLOODLIGHT 105W LPF4 Dimensions Approximate luminaire weight -23lbs (10.4kg) Fixture EPA - 0.80 sq. ft. Slipfitter (S) Trunnion Mount (T) 13.87" Beam Specs Flood (FL) Spot (SP) Initial Lumens (4K and SK)16 9,191 8,442 Average Wattage17 105W 105W LumensfWatt 88 79 NEMA Beam 6H x 6V 3H x 3V 50% beam (horizontal X vertical) 101 ° x 98' 18° x 17° 10% beam (horizontal X vertical) 127° x 125' 43° x 44' Max Candela 4,010 cd 38,212 cd 16. Lumen values based on photometric tests perlomled in compliance with IESNA LM-79. 17. System input wattage may vary based on input voltage, by up to +/- 8%, and based on manufacturer forward voltage, by up to +/- 4% Photometrics Flood (FL) Spot (SP) 3 2 1 0 1 2 3 1 .5 4 .5 3 0 2 .s 1 0 1 LPF4 105W - 20' Mounting Height, 30° Tilt Mounting Height 30 25 20 15 12 Multiplier 0.33 0.54 1.0 2.1 3.2 17.7117.71" I•ili•i_�II'Ir 1 � I•�I► 8.66" 8.66" 7.6" O 1 7.6" O �t O 6.3" 5.22" 2.56" 2.76" Trunnion Mount Bolt Pattern 0 .5 1 LPF4 105W - 25' Mounting Height, 0° Tilt Mounting Height 35 30 25 20 15 Multiplier 0.50 0.68 1.0 1.5 2.7 5.24 3.31 cm 3.0" 7.62 cm :-1.34"may 134--►4 7777iiiiII �1 3.4 cm 1 3.4 cm dia. 0.43" i3 or 7/1B•-4 - CI ( 1 ) - \/\ ���LLLJJ! 2561, 6.5 cm bolt size) bolt 0,74" dia. 0.875" 1.9 cm (1/2" or 3/4" t bolt size) Accessory Details (must be ordered separately) LPF4SG stone guard (field installed) Notes: Grid is in multiples of mounting height and values shown are in footcandles. Values shown are based on initial lumens. LytePro_LPF4 08/14 page 2 of 3 uca.r rNrvr �r �-v-+rwr v-v-u� Project Name: BETTER LIVING Old Dominion Notes: Lighting Associates rho tighlfxxlse in Orgink) Specifications General Description The Philips Stonco LytePro LED Large Floodlight 105W LPF4 combines excellent performance, design and value to meet the needs for the energy and budget conscious. The LPF4 is available with slipfitter or trunnion mounting and flood or spot optical distributions suitable for use on a wide range of applications. Two primary SKUs are available in stock for 2-day quick ship while a more comprehensive offering is available made -to -order with multiple offerings that include fusing, photocontrol, Dynadimmer, NW and CW color temps and three standard finishes. Housing Die-cast housing houses both the LED and driver assemblies. Design incorporates integrated heatsinking to maximize thermal performance and reliability. Mounting The LPF4 is available with slipfitter or trunnion mounting to allow for wide range of aiming and adjustability. Caution: Philips Stonco is not responsible for failure of mounting components supplied by others. Proper care should be exercised in mounting component selection and installation to insure adequate luminaire support, given system weight, vibration potential, exposure to the elements, thermal conditions present in the given application, etc. If luminaires are not properly supported and installed correctly per local codes and requirements, this may result in damage or injury caused by the luminaire, for which Philips Stonco is not responsible. IP Rating Entire fixture is rated IP66, including driver and optical assemblies. LED Board and Array The LPF4 utilizes four Citizen CLL032 COB (Chip On Board) LEDs. Provides up to 88 Im/W at the system level. Standard color temp is 4000K +/- 250K, with optional 5000K available. Both color temps have a minimum 80 CRI. LED Thermal Management Housing design integrates thermal heatsinking between the optical and driver assemblies, allowing for pass - through convective cooling which promotes airflow for improved and maximum heat dissipation. This results in maximized performance and reliability of critical components to ensure long LED system life. Optical Systems LPF4 Flood 'FL' is standard with a Flood 'FL' optic that consists of a specular vacuum metalized reflector that provides a very uniform and highly efficient all purpose flood distribution. Optional Spot'SP' optic consists of a TIR lens to provide a tight spot. Both optics are suitable for use in wide range of applications. Energy saving benefits and controls The LPF4 has a system efficacy of 88 firl at a system wattage of 105W using the flood distribution. With the spot distribution it has a system efficacy of 79 Im/W at a system wattage of 105W. It provides significant energy savings over traditional HID systems less controls. Optional Dynadimmer controls provides additional maximum energy savings by dimming to 25% low for 6 hours. Predicted Lumen Depreciation Data1e LYTEPRO LED LARGE FLOODLIGHT 105W LPF4 Electrical Driver efficiency (>90% standard). 120-347V available (restrictions apply). Temp range: -40°C (-40°F) to 40°C (104°F). Open/short circuit protection. RoHS compliant. Surge protector standard and is in accordance with IEEE / ANSI C62.41.2 guidelines, with a surge current rating of 10,000 amps (10KVA). Listings Product is UL and cUL listed to the UL1598 standard, suitable for Wet Locations. Suitable for use in ambients from -40°C to 40°C (-40"F to 1040F). The LPF4 luminaire with either 4K Neutral White or SK Cool White LEDs and Flood or spot optics is Design Lights Consortium® qualified. Stock SKUs of the LPF family are made in China while all made -to -order configurations are assembled in the USA. Finish Each luminaire receives a fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) textured polyester powdercoat finish. Standard finish on all stocked LPF luminaires is Textured Dark Bronze. Textured White and Dark Gray are also available as optional colors for made -to -order products. Warranty LPF4 luminaires, the LED arrays, and the drivers are all covered by a 5-year limited warranty. See philips.com/ warranties for details. Ambient Temp. -C I TM-21 Calculated L,0 hrs'"' I Reported L,0 Per TM-2119•30 I Lumen Maint. % @60,000 hrs up to 40°C 1269,000 hrs 1 >48,000 hrs 191.5% 18. Calculated performance derived from LED manufacturers data and engineering design estimates, based on IESNA LM-80 methodology. Actual experience may vary due to field application conditions. 19. Leo is the predicted time when LED performance depreciates to 70% of initial lumen output 20. Reported per IESNA TM21-11. Published Leo hours limited to 6 times actual LED test hours. © 2014 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires 9 LytePro_LPF4 08/14 page 3 of 3 Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216 Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone:800-668-9008