HomeMy WebLinkAboutSDP201600047 Review Comments Initial Site Plan 2016-09-23Short Review Comments Report for:
SDP201600047
SubApplication Type:
Staybridge Suites - Initial
Initial Site Plan
Date Completed:09/07/2016
Reviewer:Johnathan Newberry CDD Planning
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:08/05/2016
Reviewer:Jay Schlothauer CDD Inspections
Review Status:No Objection
Reviews Comments:Based on plans dated July 25, 2016.
No comments or conditions.
Division:
Date Completed:08/24/2016
Reviewer:Margaret Maliszewski CDD ARB
Review Status:Requested Changes
Reviews Comments:This item will be reviewed by the ARB on September 6, 2016. Comments will be available after that
meeting.
Division:
Date Completed:09/07/2016
Reviewer:Robbie Gilmer Fire Rescue
Review Status:See Recommendations
Reviews Comments:Based on plans dated 7/25/16.
1. Fire flow test required before final approval.
Division:
Date Completed:09/07/2016
Reviewer:Margaret Maliszewski CDD ARB
Review Status:Requested Changes
Reviews Comments:The ARB took the following actions on ARB-2016-48: Staybridge Suites Initial Site Plan at the
9/6/2016 meeting.
Regarding the initial site development plan:
Motion: Mr. Lebo moved that the ARB forward the following recommendations to the Agent for the
Site Review Committee:
• Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5):
A Certificate of Appropriateness is required prior to final site plan approval. A Certificate of
Appropriateness may be issued when the following conditions have been met.
1. Identify on the drawings the color of the smooth face panel and provide a sample for review.
2. Add the standard mechanical equipment note to the site plan. “Visibility of all mechanical
equipment from the Entrance Corridor shall be eliminated.”
3. Revise the photometric plan to show that spillover does not exceed .5 fc, including along the edge
of pavement along Laurel Park Lane.
4. Revise the photometrics using an LLF of 1.0.
5. Revise the lighting plan to make the OSQ-4MEwBLS fixtures easily legible.
6. Revise the lighting plan to include building-mounted lights.
7. Add the standard lighting note to the plan. “Each outdoor luminaire equipped with a lamp that
emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to
reflect light away from adjoining residential districts and away from adjacent roads. The spillover of
lighting from luminaires onto public roads and property in residential or rural areas zoning districts
shall not exceed one half footcandle.”
8. Revise interior parking lot trees to large shade trees.
9. Identify on the plan the color proposed for the retaining wall block.
10. Revise the plant species so that the number of proposed plants for any one species does not
exceed 25% of the total proposed for that plant type (tree, shrub).
11. Revise the cornice to more appropriately reflect the proportions of the building mass.
• Regarding recommendations on the plan as it relates to the guidelines:
1. Consider slightly darker shades for the tan wall panels.
2. Consider revising the light pole color to bronze.
• Regarding recommended conditions of initial plan approval: A Certificate of Appropriateness is
required prior to final site plan approval.
• Regarding conditions to be satisfied prior to issuance of a grading permit: None.
Mr. Binsted seconded the motion.
The motion carried by a vote of 4:0.
Division:
Page:1 of 3 County of Albemarle Printed On:July 24, 2018
reflect light away from adjoining residential districts and away from adjacent roads. The spillover of
lighting from luminaires onto public roads and property in residential or rural areas zoning districts
shall not exceed one half footcandle.”
8. Revise interior parking lot trees to large shade trees.
9. Identify on the plan the color proposed for the retaining wall block.
10. Revise the plant species so that the number of proposed plants for any one species does not
exceed 25% of the total proposed for that plant type (tree, shrub).
11. Revise the cornice to more appropriately reflect the proportions of the building mass.
• Regarding recommendations on the plan as it relates to the guidelines:
1. Consider slightly darker shades for the tan wall panels.
2. Consider revising the light pole color to bronze.
• Regarding recommended conditions of initial plan approval: A Certificate of Appropriateness is
required prior to final site plan approval.
• Regarding conditions to be satisfied prior to issuance of a grading permit: None.
Mr. Binsted seconded the motion.
The motion carried by a vote of 4:0.
Date Completed:08/30/2016
Reviewer:Matthew Wentland CDD Engineering
Review Status:See Recommendations
Reviews Comments:Based on plans dated 7-25-16:
1. Final Site Plan approval will require an approved VSMP submittal.
2. The maximum grade for parking spaces and access aisles abutting parking spaces shall not
exceed 5 percent [18.4.15.15(c)].
3. Parking spaces may be reduced to 16' when a 2' unobstructed overhang is allowed for [18.4.12.16
(c)(6)]. Please verify that the grading behind the curb for 2' does not cause an obstruction to the
overhang area.
4. Bumper blocks should be provided where a sidewalk is located closer than 2' from the edge of the
parking area and is less than 6' wide [18.4.12.16(e)].
5. For constructed slopes, the maximum steepness is 2:1 [Albemarle County Design Standards
Manual]. It appears that some areas are graded at a steeper than 2:1 slope. Any slope steeper than
3:1 must also be stabilized with landscaping vegetation hardier than grass, which will not require
mowing.
Division:
Date Completed:08/05/2016
Reviewer:Andrew Slack CDD E911
Review Status:Approved
Reviews Comments:Approved.
Division:
Date Completed:09/06/2016
Reviewer:Alexander Morrison ACSA
Review Status:Requested Changes
Reviews Comments:JT,
I have reviewed the above referenced application and have the following comments:
• Water and Sewer construction plan review submittal will be required at the final site plan
stage. Submit 3 copies of the plan along with water/sewer data sheets to the ACSA, Attn: Michael
Vieira, PE, to begin the review process.
• A sewer capacity agreement will be required prior to the ACSA recommending final site plan
or construction plan approvals.
• Show a grease interceptor.
• Call-out the sewer connection as a core and boot.
• Call out a 6” tapping sleeve and valve for the fireline.
• Show the FDC location.
• Show additional fire hydrants (per Fire/Rescue coverage requirements).
• Show a large service tap for the domestic water service.
• Call-out a water meter vault for the domestic service.
Let me know if you have any questions.
Division:
Page:2 of 3 County of Albemarle Printed On:July 24, 2018
• Show additional fire hydrants (per Fire/Rescue coverage requirements).
• Show a large service tap for the domestic water service.
• Call-out a water meter vault for the domestic service.
Let me know if you have any questions.
Date Completed:08/23/2016
Reviewer:Adam Moore VDOT
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:09/23/2016
Reviewer:Johnathan Newberry CDD Planning
Review Status:Approved
Reviews Comments:
Division:
Page:3 of 3 County of Albemarle Printed On:July 24, 2018
KSI lav' ,;lira
sr :•
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road,North Wing
Charlottesville,Virginia 22902-4596
Phonglan2A 5832 Fax(434)972-4126
September 8,2016
Brian Brewer
Kimley-Horn&Associates, Inc.
1700 Willow Lawn Drive, Suite 200
Richmond,VA 23230
brian.brewer@kimley-horn.com
RE: SDP201600047 Staybridge Suites—Initial Site Development Plan
•
Dear Mr. Brewer: 1
The Site Review Committee has reviewed the development proposal referenced above. Initial comment ' •
for the following divisions of the Department of Community Development and other agencies, as
applicable,are attached:
Albemarle County Planning Services (Planner)
Albemarle County Engineering Services (Engineer)
Albemarle County Information Services(E911)
Albemarle County Building Inspections
Albemarle County Architectural Review Board
Albemarle County Department of Fire Rescue
Albemarle County Service Authority
Virginia Department of Transportation
Comments reflect information available at the time the development proposal was reviewed,and should
not be considered final. However,the Site Review Committee has attempted to identify all issues that
will be required to be resolved prior to Final Site Plan approval.The Lead Reviewer will either approve
with conditions or deny the Initial Site Plan within 15 days of the Site Review Meeting.
Please contact me at your earliest convenience if you have questions or require additional information.
Sincerely,
a.4-
J.T.Newberry
Planner
CC: LTD Hollymead LLC
1564 Crossways Boulevard
Chesapeake,VA 23320
ndesai( ltdhospitality.com
1211)
L.
stAtAtuk e+H.aA:
Albemarle County Planning Services(Planner)—J.T.Newberry,jnewber yAalbemarle.org
1. Section 32.5.2(a)—On Sheet CA-001,under Site Statistics,please revise the zoning district to be
Planned Development—Mixed Commercial(PD-MC)and add Steep Slopes(Managed)to the list of
applicable overlay districts.
2. Section 32.5.2(a)—On Sheet CA-001,under Site Statistics,please note this site lies within Block VIII
of Hollymead Towncenter,Area C and is subject to the code of development and proffers associated
with ZMA200100020.
3. Section 32.5.2(a)—On Sheet CA-001,under Site Statistics,please note the build-to line for Block VIII
is 0-10' from the edge of sidewalk and this block permits a maximum of 76,000 square feet of non-
residential use. cst cirt".
\v-t) `S Section 32.5.2(b)—On Sheet CS-101, 104 parking spaces are provided.Please update the count on
Sheet CA-001,CS-101 and CP-101.
Cwt 5. Section 32.5.2(n)—Please note the maximum height of the retaining wall on Sheet CS-101.
6. Section 32.5.2(n)/Section 32.7.8/Section 4.17—Please revise the lighting plan in accordance with
these sections and the comments from ARB(see below).
Albemarle County Engineering Services(Engineer)—Matt Wentland,mwentlandAalbemarle.org
1. Planting plan does not have a scale or North Arrow on the sheet. Appears to be 1:20 scale.(18-32.5.2)
/2. 16'parking spaces require a 2'unobstructed overhang.(18-4.12.16.c.6) Planting plan appears to show
proposed plantings in this area.
—1( 3. Road plans will be required for thru-road construction. Road will be built and accepted into the
system or bonded prior to final site plan approval.(18-32.7.2.2)
141, Easement plat will be required for road across adjacent parcel.
5. Approved VSMP plans will be required prior to final site plan approval. (18-32.7.4.1)
6. Gutters shall be required where necessary to control or direct stormwater runoff. (18-4.12.15.g)
Virginia Department of Transportation—Adam Moore,Adam.Moore@vdot.virginia.gov—See attached
Albemarle County Department of Fire Rescue—Robbie Gilmer,rgilmerAalbemarle.org
1. Fire flow test required before final approval.
Albemarle County Information Services(E911)—Andy Slack,aslack@albemarle.org—No objection
Albemarle County Building Inspections,Jay Schlothauer,ischloth@albemarle.org—No objection
Albemarle County Architectural Review Board—Margaret Maliszewski,mmaliszewski(a,albemarle.org
Regarding requirements to satisfy the design guidelines as per§ 18-30.6.4c(2),(3)and(5):A Certificate of
Appropriateness is required prior to final site plan approval.A Certificate of Appropriateness may be issued when
the following conditions have been met.
1. Identify on the drawings the color of the smooth face panel and provide a sample for review.
2. Add the standard mechanical equipment note to the site plan. "Visibility of all mechanical equipment
from the Entrance Corridor shall be eliminated."
3. Revise the photometric plan to show that spillover does not exceed .5 fc,including along the edge of
pavement along Laurel Park Lane.
4. Revise the photometrics using an LLF of 1.0.
5. Revise the lighting plan to make the OSQ-4MEwBLS fixtures easily legible.
6. Revise the lighting plan to include building-mounted lights.
7. Add the standard lighting note to the plan. "Each outdoor luminaire equipped with a lamp that emits
3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect
light away from adjoining residential districts and away from adjacent roads.The spillover of lighting
from luminaires onto public roads and property in residential or rural areas zoning districts shall not
exceed one half footcandle."
8. Revise interior parking lot trees to large shade trees.
9. Identify on the plan the color proposed for the retaining wall block.
10. Revise the plant species so that the number of proposed plants for any one species does not exceed
25%of the total proposed for that plant type(tree,shrub).
11. Revise the cornice to more appropriately reflect the proportions of the building mass.
Regarding recommendations on the plan as it relates to the guidelines:
1. Consider slightly darker shades for the tan wall panels.
2. Consider revising the light pole color to bronze.
Albemarle County Service Authority—Alex Morrison,amorrison@serviceauthority.org
1. Water and Sewer construction plan review submittal will be required at the final site plan stage.
Submit 3 copies of the plan along with water/sewer data sheets to the ACSA,Attn:Michael Vieira,
PE,to begin the review process.
2. A sewer capacity agreement will be required prior to the ACSA recommending final site plan or
construction plan approvals.
3. Show a grease interceptor.
4. Call-out the sewer connection as a core and boot.
5. Call out a 6"tapping sleeve and valve for the fireline.
6. Show the FDC location.
7. Show additional fire hydrants(per Fire/Rescue coverage requirements).
8. Show a large service tap for the domestic water service.
9. Call-out a water meter vault for the domestic service.
•
'4b/ itare
Johnathan Newberry
From: Alexander Morrison <amorrison@serviceauthority.org>
Sent: Tuesday, September 06, 2016 10:21 AM
To: Johnathan Newberry
Subject: SDP201600047: Staybridge Suites -Initial
JT,
I have reviewed the above referenced application and have the following comments:
• Water and Sewer construction plan review submittal will be required at the final site plan stage. Submit 3 copies
of the plan along with water/sewer data sheets to the ACSA,Attn: Michael Vieira, PE,to begin the review
process.
• A sewer capacity agreement will be required prior to the ACSA recommending final site plan or construction
plan approvals.
• Show a grease interceptor.
• Call-out the sewer connection as a core and boot.
• Call out a 6"tapping sleeve and valve for the fireline.
• Show the FDC location.
• Show additional fire hydrants(per Fire/Rescue coverage requirements).
• Show a large service tap for the domestic water service.
• Call-out a water meter vault for the domestic service.
Let me know if you have any questions.
Alexander J. Morrison, P.E.
Civil Engineer
Albemarle County Service Authority
168 Spotnap Road
Charlottesville,Virginia 22911
(0)434-977-4511 Ext. 116
(C)434-981-5577
(F)434-979-0698
1
4.00
—-..- %IF \
$est, ,
COMMONWEALTH of VIRGINIA
DEPARTMENT OF TRANSPORTATION
1601 orange Road
Culpeper.Virginia 22701
Charles A.Kilpatrick,P.E.
Commissioner
August 23,2016
County of Albemarle
Department of Community Development
401 McIntire Road
Charlottesville, VA 22902
Atm: J.T. Newberry
Re: Staybridge Suites—Initial Site Plan
SDP-2016-00047
Review#1
Dear Mr.Newberry:
The Department of Transportation,Charlottesville Residency Transportation and Land Use
Section,has reviewed the above referenced plan as submitted by Kimley-Horn and associates,
Incorporated,dated 25,July 2016 and offers the following comments:
1. Please provide route numbers, ADT, design speed,public/private,and show and label
right-of-way for all streets that appear on the plan.
2. Plan sheet#CS-101;please provide proposed drainage data tying into existing storm
sewer pipe. Please show that the existing system and outfall is adequate.
3. Please conform to the pavement widening WP-2, 302_02 in the 2008 Road and Bridge
standards. Please show on plans mill and overlay.
/3 4. Provide sight distance line profiles. Please demonstrate that adequate sight distance is
��1+ provided in both horizontal and vertical.
_17',., Plan sheet#CS-101,radii on both entrances are inadequate,please refer to the Road
�` ✓' " Design Manual appendix F, and page F-126, figure 4-11. Radii should be within a range
of 25'-50' the selected shall accommodate the anticipated type of vehicle usage.
6. Plan sheet#CS-101 proposed sidewalk is outside of right of way and VDOT will not
maintain. Consider dedicating right of way for sidewalk or a land use permit will need to
be obtained.
7. It appears that Laurel Park Lane to be private, please confirm.
8. From Laurel Park Lane please show sight distance left onto Meeting Street.
9. Please extend photometric values to the surrounding street Timberwood Boulevard.
Please provide two copies of the revised plan along with a comment response letter. If further
information is desired,please contact Willis C. Bedsaul at 434-422-9866.
Please note that the final site plan must show conformance with the VDOT Road Design
Manual Appendices B (1) and F, as well as any other applicable standards, regulations,or
other requirements.
VirginiaDOT.org
WE KEEP VIRGINIA MOVING
August 23, 2016
J.T. Newberry
Page 2
VDOT Land Use Permit will be required prior to any work within the right-of-way. The
owner/developer must contact the Charlottesville Residency Transportation and Land Use
Section at (434) 422-9399 for information pertaining to this process.
Sincerely,
Adam J. Dore, P.E.
Area Land Use Engineer
Charlottesville Residency
VirginiaDOT.org