HomeMy WebLinkAboutARB201800100 Plan - Revision 2018-07-25SrlirN ut IAIL \ L_) APPROVED LJ APPROVED W/REVISIONS LJ RESUBMIT X
Ift(1) SET FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTERS TOTAL: 73.5 SQ.FT. TAX MAP AND PARCEL ID: 045131-05-OC-004AO ZONING: Highway Commercial
SCALE:TBD/NTS/PROPORTIONAL ALBEMARLE COUNTY CODE: ALLOWED 1.5 SQ. FT. PER LINEAR FOOT OF BUILDING FRONTAGE
LETTER SPECIFICATIONS:
RACEWAY MOUNTED INTERNALLY ILLUMINATED CHANNEL LETTERS
CHANNELS FABRICATED WITH ALUMINUM, FACES OF 3/16"ACRYLIC, RETURNS OF .040 ALUM., BACKS OF .063 ALUM.
BANDED WITH A .75" TRIM CAP MOLDING
NON -ILLUMINATED LETTERS;"Mexican Restaurant & Bar" TO BE FABRICATED OF 3/8"ACRYLIC, STUD -MOUNTED.
PAINTED TO
MATCH RETURNS
CUSTOMERTO PROVIDE:
ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL SIGNAGE. IF NEEDED, CUSTOMER TO PROVIDE ALL SIGNAGE DRAWINGS
TO LANDLORD FOR FINAL APPROVAL. SIGNED COPIES OF ALL FINAL SIGNAGE DRAWINGS AND QUOTES. A DEDICATED CIRCUIT WITH HOOK-UP LOGO
WITHIN 5'OF SIGN LOCATION. PAINT COLOR INFORMATION FOR RACEWAY. LETTERS
A. ALL BRANCH CIRCUITS MUST BE TOTALLY DEDICATED TO SIGNS (INCLUDING DEDICATED GROUND AND DEDICATED NEUTRAL PER CIRCUIT).
B. SIGN CIRCUITS MUST NOT BE SHARED WITH OTHER LOADS SUCH AS LIGHTING, AIR CONDITIONING, AND OTHER EQUIPMENT.
C. PROPERLY SIZED GROUND WIRETHAT CAN BE TRACED BACKTO THE BREAKER PANEL MUST BE PROVIDED.
D. NUMBER AND SIZE CIRCUITS FOR EACH SIGN TO MEET ANY LOAD REQUIREMENTS.
INSTALLER IS RESPONSIBLE FOR:
PROVIDING AND INSTALLING ALL COMPONENTS REQUREDTO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, ETC.) TO BE DETERMINED BY
LOCAL CODE AND SITE CONDITIONS PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS.
SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE PENETRATION AT EXTERIOR LOCATIONS.
x
N
251.3"W
----_4UI I II 1
MOUNTING OPTION C -EIFS
SCALE: N.T.S.
INSTALLATION BILL OF MATERIALS -EIFS
TEM#
PART#
DESCRIPTION
CITY
EFS1
HW 00123
3/8-16 x 12" SS ALL
A/R
THREAD STUD
3/8 STAINLESS
EFS2
HW 00085
STEELFLAT
A/R
WASHER
EFS3
HW-00053
3/8-16 SS FINISHED
A/R
HEX HEAD NUT
.1875 x 2 x 2 x 24.
STRUCTURAL
AL-EX-187-2-2-2
ALUMINUM ANGLE
EF54
4-ANGL-S
(2 PIECES@
A/R
LENGTH OF
RACEWAY)
3/8" SCHEDULE 40
EF55
AL-EX-375-
SCH40-20-PIPE
PIPE (ALL PIECES
ARE 4"TRIMMED IN
A/R
FIELD)
EFS6
MOUNTING-
MOUNTING
1
PATTERN
PATTERN
PAINT
EFS7
TOUCHUPPAINTT(PROUCH-
ED)&UP(PCST)
1 EA
■ TRIM CAP & RETURNS 0 RED ACRYLIC FACES; PMS 186C ❑ WHITE ACRYLIC FACES ■ FLAT CUT LETTERS
exican Restaurant & Bar
166.25"W
RACEWAY PAINTED TO MATCH
BUILDING
TOTAL S/F — 73.5 S/F
STREET FRONTAGE = 68'
SECONDARY FRONTAGE = 31'
WALL SIGN ALLOWANCE = 102 S/F
NOTE: THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON.
Client: La Michoacana SIGN PLPCBVIENT WYC!-InNGE Drawin scale: Proportional j� 7� %��17 2165 Seminole Trail Layout by: Beth Robinson x Preliminary Drawing
Location: 2291 Seminole Ln We cannot g di —tee exact color matcnea. Drawing location: P:\2018\EL - Electrical\M\Michoacana, La 080u u u 308ll Charlottesville, VA 22901 phone: (800) 482-6603 x105 ❑ Final Drawing
All sizes and dimensions are illustrated for
Charlottesville, VA 22901 clienderamodts conception of project and are net to be ���� fax', (434)974-6898 PAGE 1 OF 3
Email: egoona89@ymail.com nnast,ein9-ant ni -ac
t act scale. Revision #: 7.13.18.rev02 beth@htsva.com
Copyright Warning: This is an original unublished design created by Hightech Signs. It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever. It remains the property of Hightech Signs until legally purchased.
SIGN DETAIL
❑ APPROVED U APPROVED W/REVISIONS LJ RESUBMIT X
SIDE 2: 31' FRONTAGE
SIDE 2: 31' FRONTAGE
NOTE: THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON.
Client: La Michcoca na SIGN PLACEIVE TKAYDrawin scale: Proportional (�j �17 2165 Seminole Trail Layout b : Beth Robinson x Preliminary Drawing
Location: 2291 Seminole Ln, we aanol gua anlaa exact ooior malcnes. Drawing location: P12018\EL - Electrical\M lV ichoacona, La ���u u u ��W Charlottesville, VA 22901 p one: (800) 482-6603 xi 05 ❑ Final Drawing
All sizes and dimensions are illustrated for (�p
Charlottesville, VA 22901 client's conception of project and are not to be a�� fax: (434)974-6898
Email:egaona89@ymaiLcom understood as being exact size of exactsczie. Revision #:7.13.18.rev02 beth@htsva.com PAGE 2 OF 3
Copyright Warning: This is an original unublished design created by Hightech Signs. It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever. It remains the property of Hightech Signs until legally purchased.
SIGN DETAIL
❑ APPROVED U APPROVED W/REVISIONS ❑ RESUBMIT X
Client: La Michoacana SIGN PI.ACEIVENTKAYDrawin scale: Proportional �j7 �17 2165 Seminole Trail Layout b : Beth Robinson x Preliminary Drawing
Location: 2291 Seminole Ln, Wecannotguarantee exact colormatcnas. Drawing location: P:\2018\EL - ElechicaRM\Michoacana, La �RO u E09 Charlottesville, VA 22901 phone: (800) 482-6603 xi 05 ❑ Final Drawing
All sizes and dimensions are illustrated for (�p
Charlottesville, VA 22901 client's conception of Project and are not to be a�� fax: (434)974-6898
Email:egaono89@ymail.com understood as being exact size of exact scale. Revision #:7.13.18.reV02 beth@htsva.com PAGE 3 OF 3
Copyright Warning: This is an original unublished design created by Hightech Signs. It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever. It remains the property of Hightech Signs until legally purchased.