HomeMy WebLinkAboutSDP201600072 Calculations 2018-08-09Worksheet for Structure 3-10 YR
Prgect Desc>riphon
Solve For Spread
Input Data
Discharge
5.47
fPis
Gutter Width
2.00
ft
Gutter Cross Slope
0.083
ft/ft
Road Cross Slope
0.04
ftift
Curb Opening Length
6.00
ft
Opening Height
0.50
ft
Curb Throat Type Horizontal
Local Depression
1.50
in
Local Depression Width
1.50
ft
Throat Incline Angle
90.00
degrees
Results
Spread 9.86 ft
Depth 0.48 ft
Gutter Depression 0.09 ft
Total Depression 0.21 ft
Bentley Systems, Inc. Hasstad Methods Soldkkntl®pFtewMaster V81(SELECTserles 1) 108,11,01.03]
M12018 3:26:38 PM 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1
Worksheet for Structure 3-10 YR - Half Clogged
Project Dest;rlption
Sole For
Input .Data
Discharge
Gutter Width
Gutter Cross Slope
Road Cross Slope
Curb Opening Length
Opening Height
Curb Throat Type
Local Depression
Local Depression Width
Throat Incline Angle
Results
Spread
Horizontal
5.47
2.00
0.083
0.04
6.00
0.25
ft'Is
ft
Wit
tuft
ft
ft
1.50 in
1.50 ft
90.00 degrees
Spread 9.86 ft
Depth 0.48 ft
Gutter Depression 0.09 ft
Total Depression 0.21 ft
Bentley Systems, Inc. Haestad Methods SolObdidoiPtewMaster V81(SELECTseries 1) [08.11.01,031
8/8/2018 3:26:38 PM 27 Siemens Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1
Project Des<liphon
Solve For
Input Data
Discharge
Gutter Width
Gutter Cross Slope
Road Cross Slope
Curb Opening Length
Opening Height
Curb Throat Type
Local Depression
Local Depression Width
Throat Incline Angle
Results
Worksheet for Structure 2-10 YR
Spread
Horizontal
7.86
2.00
0.083
0.04
10.00
0.50
ft'Is
ft
ftlft
ft/ft
ft
ft
1.50 in
1.50 ft
90.00 degrees
Spread 9.96 ft
Depth 0.48 ft
Gutter Depression 0.09 ft
Total Depression 0.21 ft
Bentley Systems, Inc. Haestad Methods Soldt ntlOpEb wMaster V8i (SELECTseries 1) [08.11.01.031
8fe12018 3:26:39 PM 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1
Worksheet for Structure 2-10 YR - Half Clogged_
Project Desaipbon
Solve For
Input Data
Discharge
Gutter Width
Gutter Cross Slope
Road Cross Slope
Curb Opening Length
Opening Height
Curb Throat Type
Local Depression
Local Depression Width
Throat Incline Angle
Results
Spread
Horizontal
7.86
2.00
0.083
0.04
10.00
0.25
Wis
ft
ft/ft
fttft
ft
ft
1.50 in
1.50 ft
90.00 degrees
Spread
9.96 ft
Depth
0.48 ft
Gutter Depression
0.09 ft
Total Depression
0.21 ft
Bentley Systems, Inc. Haestad Methods Soldib"OpMewMaster V81 (SELECTseries 1 ) 108.11.01.03]
W812018 3:26:38 PM 27 Slemons Company Drive Suits 200 W Watertown, CT 09795 USA +1-203-755-1666 Page t of 1