Loading...
HomeMy WebLinkAboutARB201800102 Staff Report 2018-08-14ARCHITECTURAL REVIEW BOARD STAFF REPORT Project #/Name AR13-2018-102: Brookhill Block 813 Review Type Initial Site Plan Parcel Identification 04600000001800 Location East side of Seminole Trail (Rt. 29 N) and north side of Polo Grounds Road (Rt. 643). Forest Lakes Community is to the north and Montgomery Ridge is to the east. Zoned Neighborhood Model District (NMD)/Entrance Corridor (EC) Owner/Applicant Charles R. Haugh and E.J. Oglesby, Jr., Trustees/Scott Collins, Collins Engineering Magisterial District Rivanna Proposal To develop Block 8B with 55 lots for multi -family attached dwellings (110 units grouped into 11 buildings) and associated improvements on a 7.18-acre, L-shaped site. Context and Visibility Block 8B lies east of Rt. 29, an EC [Figure 1]. Visibility is mitigated by an existing tree line and a proposed landscape buffer 100 feet deep. Parcels to the west and south of Brookhill are rural in character, while parcels to the north and east are developed as the residential communities of Forest Lakes and Montgomery Ridge. ARB Meeting Date August 20, 2018 Staff Contact Heather McMahon PROJECT HISTORY DATE APPLICATION RESULT 11/9/2016 ZMA-2015-07 Staff comments provided on the rezoning proposal. 8/20/18 ARB-2018-102 ARB will review the initial site plan for Block 8B The ARB has reviewed an Initial Site Development Plan for Block 4A and the Final Site Development Plan for Block 4 previously, and ARB staff has provided comments on the Initial Site Development Plans for Blocks 3 and 4B. BACKGROUND In 2015, the owners of abutting Tax Map Parcels 46-18, 46-18A, and 46-19 (a combined 277.5 acres) sought a Zoning Map Amendment (ZMA-2015-07) to rezone the rural properties (zoned R-1 Residential) into a Neighborhood Model District. [Figure 2] As per the approved ZMA, 19 blocks will be formed and developed as a Neighborhood Service Center (Block 1), with Urban Density Residential (Blocks 2 through 4) and Neighborhood Density Residential (Blocks 5 through 18) development. Block 19, a reduced three -acre curtilage around Brookhill house, will be preserved. [Figure 2] This proposal entails a portion of the first phase of development and focuses on Block 8B, an L-shaped parcel encompassing 7.18 acres. [Figure 3] This initial site plan shows 11 multi -family buildings, including 55 attached condominiums amassed in groups of four, five and six units, on the east side of Stella Lane, an interior road that parallels Rt. 29 and accesses Polo Grounds Road to the south. Private streets provide access to the condominium buildings within the block. Those buildings in the southeast corner of the site are arranged around a courtyard amenity. A large stormwater management facility is proposed for the southeast corner of the site, adjacent to Polo Grounds Road. A 20-foot landscape buffer separates Block 8B from the historic Brookhill house, its curtilage reduced to a 3-acre parcel, to the northeast. Brookhill's approved Code of Development requires a 100-foot tree buffer along Rt. 29 that will screen the western boundary of Block 8B, mitigating visibility of the complex from Rt. 29, the Entrance Corridor under consideration. [Figure 4] However, until Block 8A, immediately west of Stella Lane and abutting the EC, is developed, the western half of Block 8B may be visible from the EC, despite the 100-foot landscape buffer. Therefore, the upper portions of the facades of the multi -family attached units on lots 1-15 and 38-55 may be visible. (The units on lots 16-37, in the interior of the block, are unlikely to be visible.) Figure 1: map showing TMP 46-18 (Brookhill property) and what will become Block 8B. Brookhill Development Land Use Map 1 +,' f7) F # i 8B P" MUM P I V URBEIDU5E L..J URNANDEws,tr L . 3WBGH$0RHOOO D(N9 i ■ SPIPPI SPACE k's Figure 2: Brookhill Development Land Use Map, page 7 of the Code of Development `Brookhill Neighborhood Model", approved 1119116. The 277.5-acre property has been rezoned as a Neighborhood Model District. 4 Brookhtll DevelopmLmt Illustrative Conceptual Plan Figure 3: Brookhill Development Illustrative Conceptual Plan, page 8 of the Code of Development "Brookhill Neighborhood Model", approved 1119/16. Note that the red boxes denote scope of work on this proposal, the L-shaped Block 8B. aL P c CLZ Figure 4: "Proposed 100' Buffer along Route 29 corridor, "page 20 of 'the Code of Development `Brookhill Neighborhood Model'; approved 1119116. ANALYSIS Gray highlight = means the guideline can't be reviewed at initial site plan stage, but recommendations can be provided for final Yellow highlight = means the guideline can only be reviewed for location/configuration at the initial plan stage Regular text = means the guideline can be reviewed at initial plan stage, can be made a condition of initial plan approval, and can be the basis for denial REF GUIDELINE CURRENT ISSUE RECOMMENDATION Pur ose 1 The goal of the regulation of the design of development While no architectural drawings have been Provide site sections of Block within the designated Entrance Corridors is to insure that submitted for review, the initial site plan set 8B from the EC to determine new development within the corridors reflects the exhibits 55 lots for multi -family condominiums. visibility of the proposed traditional architecture of the area. Therefore, it is the The attached buildings are grouped in clusters buildings and site structures. purpose of ARB review and of these Guidelines, that of 4, 5, and 6 to create 11 building masses proposed development within the designated Entrance dispersed through the L-shaped parcel. The Corridors reflect elements ot design characteristic ot the maximum building height is listed as 4 stories significant historical landmarks, buildings, and structures or 50 feet; the proposed heights of the buildings of the Charlottesville and Albemarle area, and to promote have not been provided. Until Block 8A is orderly and attractive development within these corridors. developed, there is potential that the western Applicants should note that replication of historic structures half of Block 8B may be visible from the EC, is neither required nor desired. dependent on the building heights. Particularly, the upper portions of the facades of lots 1-15 2 Visitors to the significant historical sites in the Charlottesville and Albemarle area experience these sites as and 38-55 may be visible. ensembles of buildings, land, and vegetation. In order to accomplish the integration of buildings, land, and This development is a densification of the site vegetation characteristic of these sites, the Guidelines not reflective of the parcel's rural character but require attention to four primary factors: compatibility with is in keeping with the suburbanization of this significant historic sites in the area; the character of the area (Forest Lakes to the north and Montgomery Entrance Corridor; site development and layout; and Ridge to the east) as well as with the rezoning landscaping. for this property as Neighborhood Model District. Compatibility with significant historic sites: 3 New structures and substantial additions to existing The historic Brookhill house is on an abutting Submit material and color structures should respect the traditions of the architecture parcel to the north. The 19t1i-century house's samples, dimensioned of historically significant buildings in the Charlottesville proportions and materiality could be utilized as elevations of the facades, and and Albemarle area. Photographs of historic buildings in an inspiration for the design of the attached floor plans of the attached the area, as well as drawings of architectural features, multi -family units proposed in Block 8B, tying multi -family buildings on lots which provide important examples of this tradition are contemporary construction to regional building 1-15 and 38-55 for review. contained in Appendix A. traditions. 4 The examples contained in Appendix A should be used as a Compatibility can be achieved through mass, See recommendation above. guide for building design: the standard of compatibility scale, form, and materiality. Sensitivity can be with the area's historic structures is not intended to impos4 achieved through siting, spatial organization, a rigid design solution for new development. Replication of and landscaping as well as through architectural the design of the important historic sites in the area is design that alludes to local architectural neither intended nor desired. The Guideline's standard of precedents through form, materiality, or style. compatibility can be met through building scale, materials, The degree to which this is accomplished can be and forms which may be embodied in architecture which id determined when architectural designs are contemporary as well as traditional. The Guidelines allow submitted for review. individuality in design to accommodate varying tastes as well as special functional requirements. COMP tibility with the character of the Entrance Corridor 5 It is also an important objective of the Guidelines to The Brookhill development, once built out, will None. establish a pattern of compatible architectural compare to the late 20r''-century suburban Forest characteristics throughout the Entrance Corridor in order to Lakes community to the north and the achieve unity and coherence. Building designs should Montgomery Hills residential community to the demonstrate sensitivity to other nearby structures within the west with its mix of single-family detached Entrance Corridor. Where a designated corridor is housing, multi -family attached housing, and a substantially developed, these Guidelines require striking commercial center. It is therefore reflective of careful balance between harmonizing new development the larger development trend on this portion of with the existing character of the corridor and achieving Rt. 29. compatibility with the significant historic sites in the area. Site develo ment and layout 6 Site development should be sensitive to the existing natural The proposed private streets run orthogonally, None. landscape and should contribute to the creation of an parallel and perpendicular to Stella Lane, the organized development plan. This may be accomplished, to public road that will provide access to the the extent practical, by preserving the trees and rolling community. The proposed grading throughout terrain typical of the area; planting new trees along streets the block is extensive and severe. Existing and pedestrian ways and choosing species that reflect vegetation will not be retained, but street trees native forest elements; insuring that any grading will blend will be provided. The proposed building heights into the surrounding topography thereby creating a have not been provided, although the maximum continuous landscape; preserving, to the extent practical, building heights are 4 stories or 50 feet. existing significant river and stream valleys which may be located on the site and integrating these features into the design of surrounding development; and limiting the building mass and height to a scale that does not overpower the natural settings of the site, or the Entrance Corridor. lands caping 7 The requirements of the Guidelines regarding landscaping The Code of Development requires a 20-foot None. are intended to reflect the landscaping characteristic of deep buffer surrounding the four sides of the many of the area's significant historic sites which is rectangular, 3-acre parcel on which the historic characterized by large shade trees and lawns. Landscaping Brookhill house sits. (The west and south sides should promote visual order within the Entrance Corridor of this buffer are reviewed here; the north side and help to integrate buildings into the existing of the buffer will be reviewed with the site plans environment of the corridor. for Block 3, while the east side will be reviewed with future site plans for Block 6.) The Grading 8 Continuity within the Entrance Corridor should be obtained_ by planting different types of plant materials that share & Drainage plan on Sheet 11 shows ample similar characteristics. Such common elements allow for planting within the west and south sides of the more flexibility in the design of structures because Brookhill house buffer. common landscape features will help to harmonize the appearance of development as seejifTom the street upon which the Corridor is centered. SPECIFIC GUIDELINES Compatibility with significant historic sites 9-15 Structure design The degree to which compatibility with local, See recommendation in #3. historic precedents is accomplished can be determined when architectural designs are submitted for review. 16 Window glass in the Entrance Corridors should not be highly Architectural information has not been Provide the standard window tinted or highly reflective. Window glass in the Entrance submitted with the initial site plan. glass note on the architectural Corridors should meet the following criteria: Visible light elevations submitted for transmittance (VLT) shall not drop below 40%. Visible review. light reflectance (VLR) shall not exceed 30%. Specifications on the proposed window glass shoul� submitted with the application for final review. Accessory structures and equipment 17 Accessory structures and equipment should be integrated No accessory structures, features, or mechanical Provide a roof plan and into the overall plan of development and shall, t equipment are shown on the site plans. If architectural elevations that possible, be compatible&ith the building designs us,1j" rooftop mechanical equipment will be proposed, show the placement and the site. roof plans that show the placement and proposed heights of the units should be proposed heights of mechanical units, if roof - 18 The following should be located to eliminate visibility from the Entrance Corridor street. If, after appropriate siting, these submitted for review. There are no loading, mounted mechanical features will still have a negative visual impact on the service or refuse areas within the residential equipment is proposed. Show Entrance Corridor street, screening should be provided to development. (A note states that each residence how all visibility of eliminate visibility. a. Loading areas, b. Service areas, c. will have individual garbage cans for mechanical equipment from Refuse areas, d. Storage areas, e. Mechanical equipment, f. collection.) The only utilities depicted (sewer, the EC will be eliminated. Above -ground utilities, and g. Chain link fence, barbed water, and stormwater) are underground; if wire, razor wire, and similar security fencing devices. above -ground utilities are proposed, such as electric, telephone, cable, etc., they should be If above -ground utilities are proposed, provide these and 19 Screening devices should be compatible with the design of the buildings and surrounding natural vegetation and may illustrated on the site plan set. No fencing is their easements on revised site consist o£ a. Walls, b. Plantings, and c. Fencingi proposed. plans. 20 Surface runoff structures and detention ponds should be A large stormwater management facility is None. designed to fit into the natural topography to avoid the need proposed for the southeast corner of the site, for screening. When visible from the Entrance Corridor adjacent to Polo Grounds Road. It is unlikely to street, these features must be fully integrated into the be visible from the EC. landscape. They should not have the appearance of engineered features. 21 The following note should be added to the site plan and the Note not provided on the site plan set. Include the mechanical architectural plan: "Visibility of all mechanical equipment equipment note on the revised from the Entrance Corridor shall be eliminated." site plans and architectural drawings. 22- Lighting Lighting information has not been submitted Provide in the site plan 31 with the initial site plan. A note within the sufficient details to show that General Notes on Sheet 1 of the site plan set all proposed light fixtures meet reads "no lighting proposed." If exterior wall- the requirements of the mounted lighting is proposed, however, fixtures lighting ordinance. should be illustrated on the architectural elevations and lighting information should be provided for review. A lighting plan with photometric values should be submitted for review, inclusive of a luminaire schedule and manufacturers' specifications and cut sheets. Lands caping 32 Landscaping along the frontage of Entrance Corridor Sheet 11 of the site plan set (entitled Grading & Provide a landscape plan for streets should include the following: Drainage, and indexed on the cover sheet as review at a scale of 1" = 30'. a. Large shade trees should be planted parallel to the Landscape Plan) illustrates street trees and the Include utilities and their Entrance Corridor Street. Such trees should be at least 3'h proposed buffer plantings, but without a plant easements on the plan, as well inches caliper (measured 6 inches above the ground) and schedule and at a scale that differs from the rest as a plant schedule. should be of a plant species common to the area. Such tre(I of the plan. As this parcel does not abut the EC, should be located at least every 35 feet on center. this guideline for frontage planting is moot. b. Flowering ornamental trees of a species common to the area should be interspersed among the trees required by the preceding paragraph. The ornamental trees need not alternate 10 one for one with the large shade trees. They may be planted among the large shade trees in a less regular spacing pattern. c. In situations where appropriate, a three or four board fence or low stone wall, typical of the area, should align the frontage of the Entrance Corridor street. d. An area of sufficient width to accommodate the foregoing plantings and fencing should be reserved parallel to the Entrance Corridor street, and exclusive of road right- of-way and utility easements. 33 Landscaping along interior roads: The street trees illustrated on Sheet 11 are Provide street trees on the east a. Large trees should be planted parallel to all interior spaced between 22 feet and 40 feet on center. and south sides of Road roads. Such trees should be at least 2% inches caliper Additionally, a note on Sheet 1 (within the E/Wesley Circle. (measured six inches above the ground) and should be of a General Notes) states that trees will be placed plant species common to the area. Such trees should be 40' o.c. Calipers and species have not been located at least every 40 feet on center. provided. However, there are no street trees on the south or east sides of Road E (elsewhere 34 Landscaping along interior pedestrian ways: a. Medium trees should be planted parallel to all interior called Wesley Circle) pedestrian ways. Such trees should be at least 2'/z inches caliper (measured six inches above the ground) and should be of a species common to the area. Such trees should be located at least every 25 feet on center. 35 Landscaping of parking areas: Nine parking spaces on the southern edge of the Provide shade trees on the a. Large trees should align the perimeter of parking areas, site are shaded by trees that abut or compose eastern edge of the site around located 40 feet on center. Trees should be planted in the some of the 30-foot landscape buffer along Polo the four parking spaces. interior of parking areas at the rate of one tree for every 10 Grounds Road, but the four parking spaces on parking spaces provided and should be evenly distributed the eastern edge of the site lack tree cover. throughout the interior of the parking area. b. Trees required by the preceding paragraph should measure 2'/2 inches caliper (measured six inches above the ground); should be evenly spaced; and should be of a species common to the area. Such trees should be planted in planters or medians sufficiently large to maintain the health of the tree and shall be protected by curbing. c. Shrubs should be provided as necessary to minimize the parking area's impact on Entrance Corridor streets. Shrubs should measure 24 inches in height. 36 Landscaping of buildings and other structures: Besides the 30-foot landscape buffer on Polo See recommendation in #33. a. Trees or other vegetation should be planted along the Grounds Road, on the southern boundary, the 11 front of long buildings as necessary to soften the stormwater management facility in the appearance of exterior walls. The spacing, size, and type of southeastern corner of the site is completely such trees or vegetation should be determined by the devoid of proposed landscaping, mitigating or length, height, and blankness of such walls. integrating its appearance into the overall b. Shrubs should be used to integrate the site, buildings, landscape from the development. and other structures; dumpsters, accessory buildings and structures; "drive thru" windows; service areas; and signs. Shrubs should measure at least 24 inches in height. 37 Plant species: No plant schedule or landscape plan has been See recommendation in #32. a. Plant species required should be as approved by the Staff submitted for review. based upon but not limited to the Generic Landscape Plan Provide the standard plant Recommended Species List and Native Plants for Virginia health note on all landscape Landscapes (Appendix D). plans submitted for review. 38 Plant health: The following note should be added to the landscape plan: "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant." Site Development and layout Develo ment paffern 39 The relationship of buildings and other structures to the The development exhibits an organized pattern See recommendation in #7. Entrance Corridor street and to other development within of streets and sidewalks. The proposed buildings the corridor should be as follows: do not front the EC, but a majority of the lots a. An organized pattern of roads, service lanes, bike paths, are oriented parallel to an interior public road, and pedestrian walks should guide the layout of the site. Stella Lane. Provisions have been made for b. In general, buildings fronting the Entrance Corridor connections to adjacent thoroughfares, such as street should be parallel to the street. Building groupings Stella Lane and Polo Grounds Road. should be arranged to parallel the Entrance Corridor street. c. Provisions should be made for connections to adjacent The courtyard amenity and the stormwater pedestrian and vehicular circulation systems. management facility in the southeast part of the d. Open spaces should be tied into surrounding areas to site are the only open spaces provided. The 20- provide continuity within the Entrance Corridor. foot landscape buffer around the Brookhill e. If significant natural features exist on the site (including house to the north, two sides of which abut creek valleys, steep slopes, significant trees or rock Block 8B, should not be considered open space. outcroppings), to the extent practical, then such natural As per the language in the Code of features should be reflected in the site layout. If the Development, the buffers fall into a separate 12 provisions of Section 32.5.6.n of the Albemarle County category, and are considered "greenspace" Zoning Ordinance apply, then improvements required by (along with greenways and parks and that section should be located so as to maximize the use of amenities). existing features in screening such improvements from Entrance Corridor streets. Most if not all of the vegetation currently on the f. The placement of structures on the site should respect site will be cleared for development, and existing views and vistas on and around the site. significant grading is proposed. Site Gradin 40 Site grading should maintain the basic relationship of the site Extensive grading is proposed throughout the See recommendations in #1 to surrounding conditions by limiting the use of retaining site, especially on the south side of the site, and and #7. walls and by shaping the terrain through the use of smooth, along the perimeter of the Brookhill house rounded land forms that blend with the existing terrain. Steep parcel, including within the landscape buffers. cut or fill sections are generally unacceptable. Proposed Retaining walls are used extensively and reach Fontours on the grading plan shall be rounded with a ten foot heights of 8' and 14'. They are located along minimum radius where they meet the adjacent condition. Road E and a portion of Alley A near the Final grading should achieve a natural, rather than Brookhill house. engineered, appearance. Retaining walls 6 feet in height and taller, when necessary, shall be terraced and planted to blend with the landscape. 41 No grading, trenching, or tunneling should occur within the Tree protection fencing is not shown on the site None. drip line of any trees or other existing features designated for plans, and existing stands of trees will be preservation in the final Certificate of Appropriateness. removed for development. However, it is the Adequate tree protection fencing should be shown on, and applicant's intention to provide several street coordinated throughout, the grading, landscaping and erosion trees throughout the development and to and sediment control plans. vegetate the 20' landscape buffer around the neighboring Brookhill house parcel. The 42 Areas designated for preservation in the final Certificate of Appropriateness should be clearly delineated and protected distance of the identified historic cultural on the site prior to any grading activity on the site. This resources (i.e., Brookhill house and the Dunn protection should remain in place until completion of the cemetery) from the proposed development development of the site. preclude disturbance from grading on Block 8B. 43 Preservation areas should be protected from storage or movement of heavy equipment within this area. 44 Natural drainage patterns (or to the extent required, new drainage patterns) should be incorporated into the finished site to the extent possible. 13 SUMMARY OF RECOMMENDATIONS Staff recommends the following as the primary points of discussion: • Visibility of the western portion of Block 8B and the need for ARB review of architectural elevations. Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee: • Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and recommended conditions of initial plan approval: 1. None. Note that a Certificate of Appropriateness is required prior to final site plan approval. • Regarding recommendations on the plan as it relates to the guidelines: None. • Regarding conditions to be satisfied prior to issuance of a grading permit: None. Regarding the final site plan submittal: 1. Architecture and landscaping will be reviewed with a future submittal. A Certificate of Appropriateness is required prior to final site plan approval. 2. Provide site sections of Block 8B from the EC to determine visibility of the proposed buildings and site structures. 3. Submit material and color samples, dimensioned elevations of the fagades, and floor plans of the attached multi -family buildings on lots 1-15 and 38-55 for review. 4. Provide the standard window glass note on the architectural elevations submitted for review: Window glass in the Entrance Corridors should meet the following criteria: Visible light transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%. 5. Provide a roof plan and architectural elevations that show the placement and proposed heights of mechanical units, if roof -mounted mechanical equipment is proposed. Show how all visibility of mechanical equipment from the EC will be eliminated. 6. If above -ground utilities are proposed, provide these and their easements on revised site plans. 7. Include the mechanical equipment note on the revised site plans and architectural drawings: Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 8. Provide in the site plan sufficient details to show that all proposed light fixtures meet the requirements of the lighting ordinance. 9. Provide a landscape plan for review at a scale of 1" = 30'. Include utilities and their easements on the plan, as well as a plant schedule. 10. Provide street trees on the east and south sides of Road E/Wesley Circle. 11. Provide shade trees on the eastern edge of the site around the four parking spaces. 12. Provide the standard plant health note on all landscape plans submitted for review: All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant. 14 0M:3 q W.1 This report is based on the following submittal items: Sheet # Drawing Name Drawing Date 1 Cover 6/25/17 2 Overall Master Plan 6/25/17 3 Overall Block Plan 6/25/17 4 Existing Conditions 6/25/17 5 Layout Plan 6/25/17 5A Utility Plan 6/25/17 6 Layout Plan 6/25/17 6A Utility Plan 6/25/17 8 (listed as 7 on Cover Sheet) Grading & Drainage Plan 6/25/17 9 (listed as 8 on Cover Sheet) Grading & Drainage Plan 6/25/17 9 Notes & Details 6/25/17 10 Notes & Details 6/25/17 11 Grading & Drainage Plan (listed as Landscape Plan on Cover Sheet list 6/25/17 12 Stormwater Management Plan 6/25/17 13 Proffers 6/25/17 14 Proffers 6/25/17 15 OF A AntA 1147.07. COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville,Virginia 22902-4596 (434)296-5823 Fax (434) 972-4012 ARB ACTION MEMO Date: August 20,2018 Time: 1:00 PM Meeting Room: Room 241,Second Floor Members: Frank Stoner: Present(Arrived at 1:08 p.m.) Frank Hancock: Present Bruce Wardell, Chair: Present Stan Binsted,Vice Chair: Present Dade Van Der Werf: Present Staff: Margaret Maliszewski Heather McMahon Sharon Taylor CALL TO ORDER Mr.Wardell called the meeting to order at 1:04 p.m.and established a quorum. DISCLOSURES Mr. Wardell invited disclosures. Hearing none,the meeting moved to the next item. PUBLIC COMMENT Mr.Wardell invited public comment. Hearing none,the meeting proceeded. CONSENT AGENDA Motion to Approve Consent Agenda: Albemarle County Architectural Review Board Final Action Memo August 20,2018 Motion: Mr. Binsted moved to approve the consent agenda and forward the recommendations outlined in the staff reports for the Initial Site Plans to the Agent for the Site Review Committee, as follows. a. ARB-2018-102: Brookhill Block 8B—Initial Site Development Plan (TM/Parcel 04600000001800) Proposal: To develop Block 8B with 55 lots for multi-family attached dwellings(110 units grouped into 11 buildings) and associated improvements on a 7.18-acre, L-shaped site. Location: East side of Seminole Trail(Rt.29 N)and north side of Polo Grounds Road(Rt.643). Forest Lakes Community is to the north and Montgomery Ridge is to the east. • Regarding requirements to satisfy the design guidelines as per§ 18-3O.6.4c(2), (3)and (5)and recommended conditions of initial plan approval: 1. None. Note that a Certificate of Appropriateness is required prior to final site plan approval. • Regarding recommendations on the plan as it relates to the guidelines: None. • Regarding conditions to be satisfied prior to issuance of a grading permit: None. • Regarding the final site plan submittal: 1. Architecture and landscaping will be reviewed with a future submittal.A Certificate of Appropriateness is required prior to final site plan approval. 2. Provide site sections of Block 8B from the EC to determine visibility of the proposed buildings and site structures. 3. Submit material and color samples, dimensioned elevations of the facades, and floor plans of the attached multi-family buildings on lots 1-15 and 38-55 for review. 4. Provide the standard window glass note on the architectural elevations submitted for review: Window glass in the Entrance Corridors should meet the following criteria: Visible light transmittance (VLT)shall not drop below 40%. Visible light reflectance(VLR)shall not exceed 30%. 5. Provide a roof plan and architectural elevations that show the placement and proposed heights of mechanical units, if roof-mounted mechanical equipment is proposed. Show how all visibility of mechanical equipment from the EC will be eliminated. 6. If above-ground utilities are proposed, provide these and their easements on revised site plans. 7. Include the mechanical equipment note on the revised site plans and architectural drawings: Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 8. Provide in the site plan sufficient details to show that all proposed light fixtures meet the requirements of the lighting ordinance. 9. Provide a landscape plan for review at a scale of 1" = 30'. Include utilities and their easements on the plan, as well as a plant schedule. 10. Provide street trees on the east and south sides of Road E/Wesley Circle. 11. Provide shade trees on the eastern edge of the site around the four parking spaces. 12. Provide the standard plant health note on all landscape plans submitted for review:All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant. Albemarle County Architectural Review Board Final Action Memo August 20,2018 2