Loading...
HomeMy WebLinkAboutSUB201800012 Plan - Approved Road Plan and Comps. 2018-05-18SITE DATA 914 MONTICELLO ROAD 1. THE OWNER WILL DESIGNATE A PROJECT MANAGER TO ACT AS OWNER'S REPRESENTATIVE DURING THIS CHARLOTTESVILLE, VA. 22902 PROJECT. CONTRACTOR SHALL REPORT DIRECTLY TO THIS PROJECT MANAGER UNLESS OTHERWISE DIRECTED. OWNER /DEVELOPER: MARCH MOUNTAIN PROPERTIES LLC CONTACT., DAVE BROCKMAN 1005 HEATHERCROFT CIRCLE, SUITE 400 CELL: (702)-985-9088 TAX MAP PARCEL No: A PORTION OF 055EO-01-7A-00000 ZONING: NEIGHBORHOOD MODEL DISTRICT IN ACCORDANCE WITH PROFFERS ge.com CROZET, VA 22932 dove®oldtrailvillage.com O LD T L V I LLAG E PLAN PREPARER, ROUDABUSH GALE & ASSOCIATES USE., 14 SINGLE FAMILY ATTACHED UNITS BUILDING HEIGHT., 3 -STORY BLOCK 7 PHASE 2 ROAD & UTILITY PLAN 914 MONTICELLO ROAD 1. THE OWNER WILL DESIGNATE A PROJECT MANAGER TO ACT AS OWNER'S REPRESENTATIVE DURING THIS CHARLOTTESVILLE, VA. 22902 PROJECT. CONTRACTOR SHALL REPORT DIRECTLY TO THIS PROJECT MANAGER UNLESS OTHERWISE DIRECTED. (434)-977-0205 TAX MAP PARCEL No: A PORTION OF 055EO-01-7A-00000 ZONING: NEIGHBORHOOD MODEL DISTRICT IN ACCORDANCE WITH PROFFERS PRESENCE ON ANY SUCH SUBSTANCE. OF ZMA 2015-00001 APPROVED FEBRUARY 10, 2016 3.THECONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED FOR THIS WORK AND PAY ALL ASSOCIATED FEES. ENTRANCE CORRIDOR OVERLAY DISTRICT THIS INCLUDES ALL NECESSARY PERMITS, INSPECTIONS, BONDS, AND OTHER APPROVAL RELATED ITEMS IN STEEP SLOPES (MANAGED) OVERLAY DISTRICT USE., 14 SINGLE FAMILY ATTACHED UNITS BUILDING HEIGHT., 3 -STORY SETBACKS: FRONT, SIDE AND REAR: 0' MINIMUM I FRONT 25' MAXIMUM PROJECT AREA: 0.69 ACRES AREA SUMMARIES: TOTAL - 0.69 ACRES CONSTRUCTION INDUSTRY (29 CFR PART 7926). LOTS - 0.52 ACRES 7. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE VDOT ROAD AND BRIDGE STANDARDS (LATEST PRIVATE ROW - 0. 17 ACRES LOT AREAS: LOT 13 1,415 SF LOT 20 1,701 SF 8. CONTRACTOR SHALL PROVIDE NECESSARY REFLECTORS, BARRICADES, TRAFFIC CONTROL DEVICES AND/OR LOT 74 1,008 SF LOT 21 1,701 SF FLAG PERSONS TO ENSURE THE SAFETY OF ITS WORKERS AND THE PUBLIC. TRAFFIC CONTROL SHALL BE LOT 15 1,003 SF LOT 22 2,215 SF DONE WITH THE KNOWLEDGE AND PERMISSION FROM THE STREET'S OWNER AND AUTHORITY. LOT 16 1,002 SF LOT 23 2246 SF 9. CONTRACTOR SHALL MAINTAIN SAFE AND PASSABLE PUBLIC ACCESS TO PROPERTIES AND THE PUBLIC LOT 17 1,003 SF LOT 24 1,700 SF RIGHT-OF-WAY DURING CONSTRUCTION. ACCESS FOR EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TIMES. LOT 18 1,477 SF LOT 25 1,700 SF 15" RCP --r'ti- LOT 19 2,167 SF LOT 26 2,242 SF GROSS RESIDENTIAL DENSITY.: 20.3 UNIT/ACRE MAGISTERIAL DISTRICT: WHITE HALL MAGISTERIAL DISTRICT STORMWATER MANAGEMENT AS DEFINED BY THE OVERALL STORMWATER MASTER PLAN (WPO20160009), APPROVED O - -- 4/25/2016 WATERSHED: LICKINGHOLE CREEK BOUNDARY SOURCE, SUBDIVISION PLAT BLOCK 7A OLD TRAIL VILLAGE OS 4954 PG 16 SUBDIVISION PLAT BLOCK 7B OLD TRAIL VILLAGE DB 4954 PG 18 x SUBDIVISION PLAT BLOCK 7A, PHASE 1 OLD TRAIL VILLAGE DB 5024 PG 429 TOPOGRAPHY: LOUISA AERIAL SURVEYS, AUGUST 2012 -- ROUDABUSH GALE & ASSOC. TOPOGRAPHIC FIELD .SURVEY FROM JUNE 2015, AUGUST 2015, NOVEMBER 2016 AND JULY 2017. BENCHMARK: TOP OF EXISTING STORM SEWER INLET #219 AT 682.30 DATUM: VERTICAL - NAVD 88, HORIZONTAL - NAD 83 FLOODPLAIN: THIS PROJECT IS LOCATED WITHIN 'ZONE X" AS SHIOWN ON FLOOD INSURANCE RATE MAP. COMMUNITY PANEL NUMBER 510003C 0237 D. EFFECTIVE DATE FEBRUARY 4. SLOPES TO BE SEEDED, MULCHED & TACKED 2005. PARKING REQUIRED: 1.5 SPACES FOR EVERY ONE -BEDROOM UNIT PLUS ONE (1) GUEST SPACE FOR FOUR (4) UNITS (6 * 1.5) + (6/4) = 10.5 PARKING SPACES VEHICLES PER DAY COUNT TWO (2) PARKING SPACES FOR EVERY UNIT PLUS ONE (1) GUEST SPACE FOR FOUR (4) UNITS \ -- - (8 * 2) + (8/4) = 78.0 PARKING SPACES TOTAL REQUIRED = 28.5 SPACES PARKING PROVIDED: 11 SPACES (6 DRIVEWAY SPACES + 5 ON -STREET PARKING SPACES) PROPOSED STREET NAME SIGN 32 SPACES (TWO GARAGE SPACES + TWO DRIVEWAY SPACES) EXISTING FLOODPLAIN TOTAL PROVIDED = 43 SPACES PROPOSED IMPERVIOUS AREA: 29,210 SF PROPOSED TURF AREA: 1,245 SF LIGHTING: 1. ALL PROPOSED LIGHTING WILL NOT EXCEED 3„000 LUMENS. EXISTING TREE DRIP LINE 2. EACH OUTDOOR LUMINARIES EQUIPPED WITH A LAMP THAT EMITS 3,000 OR MORE SANITARY MANHOLE IDENTIFIER INITIAL LUMENS SHALL BE A FULL CUTOFF LUMINARIES AND SHALL BE ARRANGED EXISTING TREE OR SHIELDED TO REFLECT LIGHT AWAY FROM ,ADJOINING RESIDENTIAL DISTRICTS STORM DRAIN STRUCTURE IDENTIFIER 1A AND FROM ADJACENT ROADS. J. ALL OUTDOOR LIGHTING SHALL BE ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING RESIDENTIAL DISTRICTS AND AWAY FROM ADJACENT ROADS. NO EVIDENCE OF A BURIAL SITE WAS FOUND ON THIS PORTION OF PARCEL Al. NO STREAM BUFFER(S) WERE FOUND ON THIS PORTION OF PARCEL A. THIS SITE IS NOT LOCATED WITHIN AN AGRICULTURAL -FORESTAL DISTRICT. THIS SITE IS LOCATED WITHIN THE SOUTH FORK RIVANNA RESERVOIR WATERSHED OF A PUBLIC WATER SUPPLY RESERVOIR. GENERAL CONSTRUCTION NOTES BLOCK 7 PHASE 2 ROAD & UTILITY PLAN VICINITY MAP SCALE: 1'=1000 FEET PLANNOTES 5.CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND LOCATIONS PRIOR TO BEGINNING WORK, AND 1. THE OWNER WILL DESIGNATE A PROJECT MANAGER TO ACT AS OWNER'S REPRESENTATIVE DURING THIS IMMEDIATELY NOTIFY THE PROJECT MANAGER IN THE EVENT THERE ARE ANY DISCREPANCIES BETWEEN SUCH PROJECT. CONTRACTOR SHALL REPORT DIRECTLY TO THIS PROJECT MANAGER UNLESS OTHERWISE DIRECTED. CONDITIONS AND THOSE SHOWN ON THE PLANS AND SPECIFICATIONS. 2. THE DESIGNER HAS CONDUCTED NO STUDIES DESIGNED TO DISCOVER THE PRESENCE OF ANY HAZARDOUS �Z' SUBSTANCES ON THIS PROPERTY AND ASSUMES NO RESPONSIBILITY OR LIABILITY RESULTING FROM THE -. --_-32 ------- PRESENCE ON ANY SUCH SUBSTANCE. LP 3.THECONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED FOR THIS WORK AND PAY ALL ASSOCIATED FEES. UTILITES& DRAINAGE SYSTEMS THIS INCLUDES ALL NECESSARY PERMITS, INSPECTIONS, BONDS, AND OTHER APPROVAL RELATED ITEMS IN -" "" -1` D,; UTILITIES 4.PAVED OR RIP RAP DITCH MAY BE REQUIRED WHEN, IN THE OPINION OF THE RESIDENT ENGINEER OR HIS i.ANY DAMAGE TO EXISTING UTILITIES CAUSED BY CONTRACTOR OR ITS SUBCONTRACTORS SHALL BE DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. �\ I 2.THESE PLANS DO NOT GUARANTEE THE EXISTENCE, NON-EXISTENCE OR LOCATION OF UTILITIES. X; r 6. ALL EXCAVATIONFOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE � I CONSTRUCTION INDUSTRY (29 CFR PART 7926). (1-800-552-7001) AND/OR THE RESPECTIVE UTILITY COMPANIES FOR GAS, WATER, SEWER, POWER, PHONE 7. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE VDOT ROAD AND BRIDGE STANDARDS (LATEST rlll01 EDITION) AND THE VDOT ROAD AND BRIDGE SPECIFICATIONS (LATEST EDITION). RESPECTIVE OWNER, IF THE METHOD OF PROTECTION IS NOT OTHERWISE SPECIFIED. CONTRACTOR SHALL 8. CONTRACTOR SHALL PROVIDE NECESSARY REFLECTORS, BARRICADES, TRAFFIC CONTROL DEVICES AND/OR c°°, Rid - FLAG PERSONS TO ENSURE THE SAFETY OF ITS WORKERS AND THE PUBLIC. TRAFFIC CONTROL SHALL BE RULES AND REGULATIONS. ANY COST INCURRED FOR REMOVING, RELOCATING OR PROTECTING UTILITIES DONE WITH THE KNOWLEDGE AND PERMISSION FROM THE STREET'S OWNER AND AUTHORITY. I, 9. CONTRACTOR SHALL MAINTAIN SAFE AND PASSABLE PUBLIC ACCESS TO PROPERTIES AND THE PUBLIC BURIED UTILITIES FAR ENOUGH IN ADVANCE OF ITS WORK TO ALLOW FOR HORIZONTAL AND /OR VERTICAL ADJUSTMENTS TO ITS WORK AND/OR THE UTILITIES. NO ADJUSTMENT IN COMPENSATION OR SCHEDULE WILL RIGHT-OF-WAY DURING CONSTRUCTION. ACCESS FOR EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TIMES. BE ALLOWED FOR DELAYS RESULTING FROM CONTRACTOR'S FAILURE TO CONTACT AND COORDINATE WITH UTILITIES 15" RCP --r'ti- PROPOSED REDUCER ► W F HANDICAP RAMP (CG -12) J O - -- DENOTES LO TION STD. -�/ PROPOSED SANITARY SEWER --------- C- AL C.ANO OR JURISDICTIONAL IE STANDARD MP CONSTRUCTION � x PARKING INDICATOR 12 PROPERTY LINE -- INDICATES THE NUMBER OF TYPICAL PARKING SPACES EASEMENT LINE - --- BENCHMARK CENTERLINE --- CRITICAL SLOPE LIMITS OF CLEARING AND/OR GRADING - SLOPES TO BE SEEDED, MULCHED & TACKED EXISTING SPOT ELEVATION +12.0 VEHICLES PER DAY COUNT 1,231, VPD \ -- - BLOCK 7 - PH. 2 PROPOSED STREET NAME SIGN + EXISTING FLOODPLAIN EXISTING SIGN STREAM BUFFER PROPOSED SIGN �- EXISTING TREE DRIP LINE SANITARY MANHOLE IDENTIFIER 01 EXISTING TREE EX. 15' uAK STORM DRAIN STRUCTURE IDENTIFIER 1A i Ilaa I. v Rte 250 Ll - ( I VICINITY MAP SCALE: 1'=1000 FEET PLANNOTES 5.CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND LOCATIONS PRIOR TO BEGINNING WORK, AND 1. THE OWNER WILL DESIGNATE A PROJECT MANAGER TO ACT AS OWNER'S REPRESENTATIVE DURING THIS IMMEDIATELY NOTIFY THE PROJECT MANAGER IN THE EVENT THERE ARE ANY DISCREPANCIES BETWEEN SUCH PROJECT. CONTRACTOR SHALL REPORT DIRECTLY TO THIS PROJECT MANAGER UNLESS OTHERWISE DIRECTED. CONDITIONS AND THOSE SHOWN ON THE PLANS AND SPECIFICATIONS. 2. THE DESIGNER HAS CONDUCTED NO STUDIES DESIGNED TO DISCOVER THE PRESENCE OF ANY HAZARDOUS 7. IN THE EVENT THAT GRADING AS SHOWN ON THE PLANS IS NOT FEASIBLE CONTRACTOR SHALL ADVISE THE PROJECT MANAGER AND ENGINEER BEFORE FINAL GRADING COMPLETION FOR ADVICE AND CONSENT. SUBSTANCES ON THIS PROPERTY AND ASSUMES NO RESPONSIBILITY OR LIABILITY RESULTING FROM THE -. --_-32 ------- PRESENCE ON ANY SUCH SUBSTANCE. LP 3.THECONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED FOR THIS WORK AND PAY ALL ASSOCIATED FEES. UTILITES& DRAINAGE SYSTEMS THIS INCLUDES ALL NECESSARY PERMITS, INSPECTIONS, BONDS, AND OTHER APPROVAL RELATED ITEMS IN -" "" -1` ACCORDANCE WITH THESE PLANS AS WELL AS LOCAL, STATE, AND FEDERAL POLICIES. UTILITIES 4.PAVED OR RIP RAP DITCH MAY BE REQUIRED WHEN, IN THE OPINION OF THE RESIDENT ENGINEER OR HIS i.ANY DAMAGE TO EXISTING UTILITIES CAUSED BY CONTRACTOR OR ITS SUBCONTRACTORS SHALL BE DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. CONTRACTOR'S SOLE RESPONSIBILITY AND REPAIRED AT CONTRACTOR'S EXPENSE. 5.ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL 2.THESE PLANS DO NOT GUARANTEE THE EXISTENCE, NON-EXISTENCE OR LOCATION OF UTILITIES. DEVICES, LATEST EDITION, AND SHALL BE PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL VERIFY THE EXISTENCE AND LOCATION OR THE NON-EXISTENCE OF UTILITIES. AT LEAST 6. ALL EXCAVATIONFOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE 48 HOURS PRIOR TO ANY EXCAVATION OR CONSTRUCTION, CONTRACTOR SHALL NOTIFY MISS UTILITY CONSTRUCTION INDUSTRY (29 CFR PART 7926). (1-800-552-7001) AND/OR THE RESPECTIVE UTILITY COMPANIES FOR GAS, WATER, SEWER, POWER, PHONE 7. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE VDOT ROAD AND BRIDGE STANDARDS (LATEST AND CABLE. CONTRACTOR SHALL TIMELY ARRANGE TO HAVE THE VARIOUS UTILITIES LOCATED, AND TO HAVE THEM REMOVED OR RELOCATED, OR TO DETERMINE THE METHOD OF PROTECTION ACCEPTABLE TO THE EDITION) AND THE VDOT ROAD AND BRIDGE SPECIFICATIONS (LATEST EDITION). RESPECTIVE OWNER, IF THE METHOD OF PROTECTION IS NOT OTHERWISE SPECIFIED. CONTRACTOR SHALL 8. CONTRACTOR SHALL PROVIDE NECESSARY REFLECTORS, BARRICADES, TRAFFIC CONTROL DEVICES AND/OR CONDUCT ITS WORK IN THE VICINITY OF EXISTING UTILITIES IN ACCORDANCE WITH THE RESPECTIVE UTILITY'S FLAG PERSONS TO ENSURE THE SAFETY OF ITS WORKERS AND THE PUBLIC. TRAFFIC CONTROL SHALL BE RULES AND REGULATIONS. ANY COST INCURRED FOR REMOVING, RELOCATING OR PROTECTING UTILITIES DONE WITH THE KNOWLEDGE AND PERMISSION FROM THE STREET'S OWNER AND AUTHORITY. SHALL BE BORNE BY CONTRACTOR UNLESS INDICATED OTHERWISE. CONTRACTOR SHALL EXCAVATE TO LOCATE 9. CONTRACTOR SHALL MAINTAIN SAFE AND PASSABLE PUBLIC ACCESS TO PROPERTIES AND THE PUBLIC BURIED UTILITIES FAR ENOUGH IN ADVANCE OF ITS WORK TO ALLOW FOR HORIZONTAL AND /OR VERTICAL ADJUSTMENTS TO ITS WORK AND/OR THE UTILITIES. NO ADJUSTMENT IN COMPENSATION OR SCHEDULE WILL RIGHT-OF-WAY DURING CONSTRUCTION. ACCESS FOR EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TIMES. BE ALLOWED FOR DELAYS RESULTING FROM CONTRACTOR'S FAILURE TO CONTACT AND COORDINATE WITH UTILITIES EARTHWORK, DRAINAGE. & SITE CONDITIONS 1. EXCEPT AS OTHERWISE SHOWN ON THE PLANS, ALL CUTS AND FILLS SHALL MATCH EXISTING SLOPES OR BE NO GREATER THAN 2:1. 2. UNLESS OTHERWISE NOTED ON THE PLANS OR IN THE SPECIFICATIONS, ALL FILL MATERIALS SHALL BE COMPACTED TO 95% OF THEORETICAL MAXIMUM DENSITY AS DETERMINED BY AASHTO T-99 METHOD A, WITHIN PLUS OR MINUS 2% OF OPTIMUM MOISTURE, FOR THE FULL WIDTH AND DEPTH OF THE FILL. 3. ALL GRADING AND IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA UNLESS OTHERWISE INDICATED. TALL MATERIALS AND INSTALLATION DETAILS SHALL CONFORM TO APPLICABLE LOCAL ORDINANCES AND VDOT ROAD & BRIDGE STANDARDS (LATEST EDITION) UNLESS OTHERWISE STATED WITHIN THE PLANS.. 5.ANY UNUSUAL OR UNANTICIPATED SUBSURFACE CONDITIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER. 3.WHEN THE WORK CROSSES EXISTING UTILITIES, THE EXISTING UTILITIES SHALL BE ADEQUATELY SUPPORTED AND PROTECTED FROM DAMAGE DUE TO THE WORK. ALL METHODS FOR SUPPORTING AND MAINTAINING THE EXISTING UTILITIES SHALL BE APPROVED BY THE RESPECTIVE UTILITY COMPANY AND/OR THE ENGINEER. CONTRACTOR SHALL EXERCISE CARE TO INSURE THAT THE GRADE AND ALIGNMENT OF EXISTING UTILITIES ARE MAI NTAINEDAND THAT NO JOINTS OR CONNECTIONS ARE DISPLACED. BACKFILL SHALL BE CAREFULLY PLACED AND COMPACTED TO PREVENT FUTURE DAMAGE OR SETTLEMENT TO EXISTING UTILITIES. ANY UTILITIES REMOVED AS PART OF THE WORK, AND NOT INDICATED TO BE REMOVED OR ABANDONED, SHALL BE RESTORED USING MATERIALS AND INSTALLATION EQUAL TO THE UTILITY'S STANDARDS. T CONTRACTOR SHALL NOTIFY LANDOWNERS, TENANTS AND THE PROJECT MANAGER PRIOR TO THE INTERRUPTION OF ANY SERVICES. SERVICE INTERRUPTIONS SHALL BE KEPT TO A MINIMUM AND SHALL ONLY OCCUR WITH THE KNOWLEDGE AND PERMISSION OF THE SERVICE'S OWNER OR AUTHORITY. 5.11HE ADJUSTMENT OF ALL MANHOLE TOPS, WATER VALVE BOXES, GAS VALVE BOXES AND WATER METER BOXES SHALL BE THE RESPONSIBILITY OF CONTRACTOR. APPROVED by the Albemarle County Community Devi !opmec' Department Date i I `�_JA File_ (1 cult'' -- E KY'2 SHEET INDEX SHEET 1 --------- COVER SHEET SHEET 2 --------- EXISTING CONDITIONS & DEMOLITION PLAN SHEET 3 --------- SITE PLAN SHEET 4 --------- GRADING PLAN SHEET 5 ---------DRAINAGE AREA MAP SHEET 6 --------- PROFILES SHEET 7 ------- TYPICAL SECTIONS, NOTES & DETAILS SHEET 8 --------- CONSTRUCTION NOTES & DETAILS SHEET 9 --------- ACSA WATERLINE DETAILS SHEET 10 --------- ACSA SANITARY SEWER DETAILS 6.ALL WATER METER, VALVES AND FIRE HYDRANT ADJUSTMENTS/RELOCATIONS SHALL BE PERFORMED BY THE CONTRACTOR. CONTRACTOR SHALL KEEP A "REDLINE" SET OF PLANS DOCUMENTING ALL SUCH AS -BUILT REVISIONS. DRAINAGE SYSTEMS 1.CONTRACTOR SHALL EXERCISE CARE, ESPECIALLY AT INTERSECTIONS AND GUTTER LINES, TO PROVIDE POSITIVE DRAINAGE. ANY AREAS WHERE WATER IS IMPOUNDED SHALL BE CORRECTED BY CONTRACTOR AT NO ADDITIONAL COST, POSITIVE DRAINAGE OF ALL ROADWAY AREAS TO THE STORM DRAIN INLETS OR OTHER ACCEPTABLE DRAINAGE CHANNELS AS NOTED ON THE PLANS IS REQUIRED. 2.CONTRACTOR SHALL MAINTAIN EXISTING STREAMS, DITCHES, DRAINAGE STRUCTURES, CULVERTS AND FLOWS AT ALL TIMES DURING THE WORK, CONTRACTOR SHALL PAY FOR ALL PERSONAL INJURY AND PROPERTY DAMAGE WHICH MAY OCCUR AS A RESULT OF FAILING TO MAINTAIN ADEQUATE DRAINAGE. 3. ALL PIPES, DI'S AND OTHER STRUCTURES SHALL BE INSPECTED BY THE PROJECT MANAGER BEFORE BEING BACKFILLED OR BURIED. THE PROJECT MANAGER MAY REQUIRE CONTRACTOR, AT NO ADDITIONAL COST, TO UNCOVER AND RE-COVER SUCH STRUCTURES IF THEY HAVE BEEN BACKFILLED OR BURIED WITHOUT SUCH INSPECTION. 4. ALL CATCH BASINS ENCOMPASSED WITHIN NEW CONSTRUCTION SHALL BE CONVERTED TO DROP INLETS. 5.REMOVED PIPE SHALL BE THE PROPERTY OF CONTRACTOR UNLESS NEGOTIATED OTHERWISE BEFORE PROJECT BIDDING; AND IF NOT SALVAGED FOR RE -USE, SHALL BE DISPOSED OF LAWFULLY. 6. ALL STORM SEWER PIPE AND DROP INLETS SHALL BE CLEARED OF DEBRIS AND ERODED MATERIAL PRIOR TO FINAL ACCEPTANCE. 7. ALL STORM SEWER PIPE JOINTS SHALL BE SEATED AND SEALED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. 8.ALL EXISTING ROOF DRAINS AND OTHER DRAINAGE CONDUIT BLOCKED OR DISRUPTED FROM THEIR PRE -CONSTRUCTION DRAINAGE PATTERNS SHALL BE SHORTENED, EXTENDED OR OTHERWISE ROUTED USING MATERIALS APPROVED BY THE ENGINEER, AND IN SUCH A WAY THAT THE NEW DRAINAGE PATTERNS ARE ACCEPTABLE TO ENGINEER AND THE PROJECT MANAGER. APPROVALS LEGEND DATE PLANNING / ZONING ENGINEERING INSPECTIONS EXISTING INTERMEDIATE CONTOUR -. --_-32 ------- PROPOSED TREE LP EXISTING INDEX CONTOUR --- '---- 30 EXISTING WATERLINE W/ TEE -" "" -1` PROPOSED CONTOUR 20 PROPOSED WATERLINE W/ TEE W EXISTING EDGE OF PAVEMENT - EX. EP _ EXISTING FIRE HYDRANT PROPOSED EDGE OF PAVEMENT - EP ------- PROPOSED FIRE HYDRANT ¢- EXISTING CURB AND GUTTER - - EX. C&G - - - EXISTING WATER VALVE PROPOSED CURB AND GUTTERCG-6 PROPOSED WATER VALVE - 8 W CGCG 6OLL-TOP-TOP TRANSITION FROM CG -6 ROLL-TOP PROPOSED WATER METER � EXISTING STORM SEWER EX. 15" RCP_ EXISTING REDUCER ► PROPOSED STORM SEWER 15" RCP --r'ti- PROPOSED REDUCER ► W HANDICAP RAMP (CG -12) EXISTING SANITARY SEWER O - -- DENOTES LO TION STD. -�/ PROPOSED SANITARY SEWER --------- C- AL C.ANO OR JURISDICTIONAL IE STANDARD MP CONSTRUCTION PARKING INDICATOR 12 PROPERTY LINE -- INDICATES THE NUMBER OF TYPICAL PARKING SPACES EASEMENT LINE - --- BENCHMARK CENTERLINE --- CRITICAL SLOPE LIMITS OF CLEARING AND/OR GRADING - SLOPES TO BE SEEDED, MULCHED & TACKED EXISTING SPOT ELEVATION +12.0 VEHICLES PER DAY COUNT 1,231, VPD PROPOSED SPOT ELEVATION+12.0 LIMITS OF DEMOLITION XXXXXXXX - PROPOSED STREET NAME SIGN + EXISTING FLOODPLAIN EXISTING SIGN STREAM BUFFER PROPOSED SIGN �- EXISTING TREE DRIP LINE SANITARY MANHOLE IDENTIFIER O EXISTING TREE EX. 15' uAK STORM DRAIN STRUCTURE IDENTIFIER 1A 6.ALL WATER METER, VALVES AND FIRE HYDRANT ADJUSTMENTS/RELOCATIONS SHALL BE PERFORMED BY THE CONTRACTOR. CONTRACTOR SHALL KEEP A "REDLINE" SET OF PLANS DOCUMENTING ALL SUCH AS -BUILT REVISIONS. DRAINAGE SYSTEMS 1.CONTRACTOR SHALL EXERCISE CARE, ESPECIALLY AT INTERSECTIONS AND GUTTER LINES, TO PROVIDE POSITIVE DRAINAGE. ANY AREAS WHERE WATER IS IMPOUNDED SHALL BE CORRECTED BY CONTRACTOR AT NO ADDITIONAL COST, POSITIVE DRAINAGE OF ALL ROADWAY AREAS TO THE STORM DRAIN INLETS OR OTHER ACCEPTABLE DRAINAGE CHANNELS AS NOTED ON THE PLANS IS REQUIRED. 2.CONTRACTOR SHALL MAINTAIN EXISTING STREAMS, DITCHES, DRAINAGE STRUCTURES, CULVERTS AND FLOWS AT ALL TIMES DURING THE WORK, CONTRACTOR SHALL PAY FOR ALL PERSONAL INJURY AND PROPERTY DAMAGE WHICH MAY OCCUR AS A RESULT OF FAILING TO MAINTAIN ADEQUATE DRAINAGE. 3. ALL PIPES, DI'S AND OTHER STRUCTURES SHALL BE INSPECTED BY THE PROJECT MANAGER BEFORE BEING BACKFILLED OR BURIED. THE PROJECT MANAGER MAY REQUIRE CONTRACTOR, AT NO ADDITIONAL COST, TO UNCOVER AND RE-COVER SUCH STRUCTURES IF THEY HAVE BEEN BACKFILLED OR BURIED WITHOUT SUCH INSPECTION. 4. ALL CATCH BASINS ENCOMPASSED WITHIN NEW CONSTRUCTION SHALL BE CONVERTED TO DROP INLETS. 5.REMOVED PIPE SHALL BE THE PROPERTY OF CONTRACTOR UNLESS NEGOTIATED OTHERWISE BEFORE PROJECT BIDDING; AND IF NOT SALVAGED FOR RE -USE, SHALL BE DISPOSED OF LAWFULLY. 6. ALL STORM SEWER PIPE AND DROP INLETS SHALL BE CLEARED OF DEBRIS AND ERODED MATERIAL PRIOR TO FINAL ACCEPTANCE. 7. ALL STORM SEWER PIPE JOINTS SHALL BE SEATED AND SEALED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. 8.ALL EXISTING ROOF DRAINS AND OTHER DRAINAGE CONDUIT BLOCKED OR DISRUPTED FROM THEIR PRE -CONSTRUCTION DRAINAGE PATTERNS SHALL BE SHORTENED, EXTENDED OR OTHERWISE ROUTED USING MATERIALS APPROVED BY THE ENGINEER, AND IN SUCH A WAY THAT THE NEW DRAINAGE PATTERNS ARE ACCEPTABLE TO ENGINEER AND THE PROJECT MANAGER. APPROVALS DEPARTMENT OF COMMUNITY DEVELOPMENT DATE PLANNING / ZONING ENGINEERING INSPECTIONS ARCHITECTUAL REVIEW BOARD DEPARTMENT OF FIRE RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VA. DEPARTMENT OF TRANSPORTATION REVISIONS 03/28/2018 COUNTY COMMENTS 05/02/2018 COUNTY COMMENTS DATE JAN. 12, 2018 SCALE AS SHOWN CONTOUR INTERVAL NA N W Wg0 WQagz W=�J� � (- :3 Z J 0 W��Q� >Y06C 0 O C) J0J m 0 FILE NUMBER 8053 SHEEP Fj Of 10 17,111\3D)!_['. I\=n T- '.Foal PI -IFI, .. ] P,,- " Fr.,I Fl- n,, /"-,i: -,.nl 111 Q\F,GA',T[,1PF,j,N,F,j13-r1D TM,'1L,,PLD_', T,,Fh,­ 2„ ,I FI,A1­H I P,- ' F,,,,l 5,`11111 31611q FIV 1- Nz� <* < V 0 Q. a,- 5.0 tw Lou d8r U, a: q Z c i F, MARCH MOUNTAIN PROPERTIES, LLC D.— IMP 55E -01 -JA -1 77—USE POOL 0ffiNc___* _z A"r - JA-2AN LLC I'D 'Ad, ", jC EX. , : O,_ o¢pUSE VACANT Z� ----------- ------ LLI ZONING NMD LL ri) 0 ru 0 (6 Ir— 1� In -4 0 0 uj EX. X �N �0 LU ri —77EJ A z 0 �Lu E, EX. EC� _694 EX. OLD TRAIL DRIVE --WEVISIONS _T O.Q.VAR. WIDTH UHLI R -O -W 03 2336 1,34 5S�1� P PGC T EjI'T 03/28/2018 COUNTY COMMENTS EX.- -�W ONC. s, -M-57 -E-69.:70' MARCH MOUNTAIN PROPERTIES, LLC xxxx Fx K,:� �PE 3A IMP 55 -01-76 USE. VACANT 6 z� ZONING. RAID 05/02/2018 COUNTY COMMENTS D3 4954 PC 18 A�_ SOILS UNE---­-�_ a o - A ___(TyP aF FUTUREas it ;YPL* 26C' Sty COMMERCIAL �--ED EA,V ES�l T PA 42 11 JEX. STORM SEWER PIPE TO �d _�02 iti E REMOVED AND REPLACED ff SOIL TYPE 25B N� DATE N Im JAN. 12, 2018 SCALE--------------- n DR �0'4 PC'4�9 1 30, C) El J LML r: `1 T FUTURE PA 15 5024 PC21,0 PARKING Lu CONTOUR INTERVAL :.,' "y. 1' ' AREA L.2 k. z �'\_ / I /' - 1\ - CL'L / '. �� L MARCH MOUNTAIN PROPERTIES, LLC IMP 55E -01-7A 3 FEET USE, VACANT ZONING: NMD M, LIS 4954 PG Y6 12+00 WE 11,00 z cli n L LI Z X. SEW7- AC -A il;,L EEV'T 6! 410�, Fc 539 DB 51 IL 0 Lu _j Lu 5 E�. El 0 U) CL z MARCH MOUNTAIN PROPERTIES, LLC-' STI�ELT 12 11 10 9 IMP 55E DI J5D (TYPj USE, VACANT ZONING NUD 03 6 _71 w "N EX. Y _T� EV. DR' C- L�AIY_R�l -------30*03'45' K '0`41A tx cm, sw D.E. TT I, J E 47 P. SOILS LINE 2--= EXE; (Typ.) J z N D P: C6 Ir e6' �2A E, 4' ,L_A 1 7T O 7- - [ �Fv. _ER__ORION UNE 0 U z 0<0 < o 13 Zi\ 3 NCHMARK-------_,, DOW ET F, 1?, ivA EX. M.89 ---- --j - — — — — — — 1682.30 INL I CR "ZIUSC, _L _ ___ I. 1; 0 —10 0 �,v -ILI D5 -114 PG CRAIG EN I INC EX. cv. EX. IMP 55E-01-27-5/MARCH UNTAIN MARC I MOUN I ` �A) / USE, RESIDENTIAL PH PERTES, LLC 0 z U)i PROPERTIES, L ZONING. N 0 IMP 55E-01 21 12 TMP 55E 1-2 __O ARCH 1 25 ARC" LX USE. VACANT PROPER L X, ZONING NUD _,_,�ACANT / TT IMP 55 1 - — w NOTE: Ptica of CURVE RADIUS ARC LENGTH CH CHORD BEARING DELTAANGLE OLDHAM DRIVE, FENNEL ROAD AND GREENWELL LANE EAST OF ORION — 1517.50' 205.11' 204.95' S 26'45'26" E L�4 C, 7 4%�,7 LANE AND ASSOCIATED UTILITY INFRASTRUCTURE HAVE BEEN APPROVED, C2 70.00' 103.65' 94.44' S 15-36'16" W 84-50 20 BONDED AND ARE CURRENTLY UNDER CONSTRUCTION AND ARE SHOWN N 76*01'07" W ' ' HEREON THIS PLAN AS EXISTING. PLEASE REFER TO OLD TRAIL VILLAGE, 915454 UM NUMBER 0 8 53 C3 2.5V 20.05' 17.9�' C4 469.50' 156.35' 155.63' 1904491, BLOCK 7 PHASE I ROAD AND UTILITY PLANS FOR MORE INFORMATION. LEGEND I gg"t '' N 20'31'20" W y C5 12.50' 19.84' 17.82' Lm. N., N 34°28'40" E 90'55'11 22841 ❑ STEEP SLOPES (MANAGED) �oFS810NAL wo, SCALE 1-30' 30 0 30 60 SHEET SCALE IN FEET 2 of 10 Q\F,GA',T[,1PF,j,N,F,j13-r1D TM,'1L,,PLD_', T,,Fh,­ 2„ ,I FI,A1­H I P,- ' F,,,,l 5,`11111 31611q FIV 1- �y I 2W>0, 5a Lu ° -D III,\ccN o'dVJ J Z N _ II W' _ — -- T MARCH MOUNTAIN I I PROPERTIES, LLC --..., TMP 55E 01 3A 1 _ p II I s 2 D (o W � - _ — USE: POOL .' .... _ _�- W v h -- —� 1— Z6N4G NMD- 7 o ow W ��� ¢ ¢ 3_ _ ,Wi'j 22 R'j W2 2yh2E Y W2 �M2= U3MZZ U�2� I ~ ¢ 2 WO 2 I �UQO UUtiU I IMP 55E 01-JC A _'/. I I l �1 ` \' FT+1 O 1 W F�� ry�. C W Z ^Q . ._ --_ --�• —..-�� a 0 o U O W W h OW W W xQOin h `. 2d'nN W4R°nN �4���JN YttiyN �24lWnN j'�4i0 �Y4°�2 __ � U- ¢QEJ yEJ �J �Oti �J Uti�J E�j°v ' h2 J ti g 2 h USE.- VACANT ZONING NMB 3S - 2 2inK 2"W7 2 /%// W�n�p 3hiup --\ \ .� W y O W - x — -- — =' W c % OLD TRAIL DRIVE VAR. WIDTH -PBLIC--R-O-w - OB 2886 PG 134 �--- --_. _ _ I - - REVISIONS PROP I BLIC / 03/26/2018 - --'22:00''0 1 STr f M1I'T. � \ --�"� COUNTY COMMENTS / / _ 2;1-4 MARCH MOUNTAIN PROPERTIES, LLC \ - - _ _ IMP55E-01-78 I 1 - - - \ - - - _ USE VACANT \ __ \ - \ - - - _ \\ j / 05/02/2018 COUNTY COMMENTS l ZONING: NMD \ LOB 4954 PG 18 1 '� ' 24 'M IM I� I� Iv 26 25 - _ \ _-�- I ., ///" 0 I23 1 , ^ 1 2220 � I 21 IN I W 19 T - FUTURE COMMERCIAL / ,1 R7-1 R7-1 R7-1 PARCEL _ I W, I W U PROP. PRIV. 4.26' ROP. UTI M'T. �-� STRM, ESM'T. - 3 0' 22 fid' _ ROLL To'b cu .' %' b FENN RO D ✓i`r MATCH EX. CURB I _ M dfl'�-:_�. l` I 4 ¢ 2uWj��= I ,W�a I oJN DATE \ 2018 EX. 57N -W ,.. ,.: - : .:.. ....:...... } - - EX. TEMP. STORM - l nB 502-+ HU 13 '� �: m m PRO wSW ^ Le, - - - - DRAINAGE ESM'T. / - R1-1 MAI NANC - DB 5037 PG 778 / R7_7 AFFORD. 1 LII CONTOUR INTERVAL _ p _ �/ 13 14 15 X16 M 17 AEEo$D Er r snl'I I 24" AFFORD. AFFORD. AFFORD AFFORD U -4 Pl +- _ _ Ili STOP FUTURE PARKING ��� �% W I rs,E F r; i� \ \\\ / / MATCH EX. CURB AREA MARCH MOUNTAIN PROPERTIES, LLC `-�` Fl—TMP 55E-01-7A '•85' J USE. VACANT, 16.00' 16.00 16.00' 1fi.00' 23 2 _ ZONING: NMD OB 4954 PG 16� 1 : 3 h W — — 1 +D �GREENWELLLAN_ - o - - -- ' l . ;j_; - H, 11+ao -.�,; � x Z1D oe _ i i EIfT W „ 4 w= Q- a L_L_ s, �•§ / / /i. -�� .�Fx acsn :v E°✓'r _ _ 1 `� B 470.1 PG .fig Q' _ 'I ..SE✓ I / 1 . - O R',,.4 r-...... - O . -' _�__ �. - _,�.-E, unL Fs rr ,5n ,4 Pv 1 ti %` R I j�Jnl I N �:• MARCH MOUNTAIN PROPERTIES, LCC ✓ /�) i; 7 - .:I ¢ N a 1!`1 +¢;4 i_..Y S' TMP 55E-01-35D / / 1 / i _ \ '! 12 11 o S f USE. / ` VACANT l ZONING: NMD- - 7 n /VQOa rel✓ ., — -- L r— s a" — - - _ W 06 i.\ - E�M E � ORION LANE �J704L _ ' 0Q cl 1 r ri _ ,. g'P'• ". `V.,,;' - - - - - - - - BENCHMARK - \ 70P STM. ET OB C 38 _ - - - - _ - - - - - - _._ _.. J - ._ 682-10 - - • -- -----_ _- -� _ l //l CRAIG ENTERPRISES INC ll - v - •. TMP 55E-01-27-5 I -_ MPARSCS_HE MOOl U,N2T7AI I-�L l 141 / ✓ _ IIl/'� '` USE: RESIDENTIAL'''l�J NMD I TM - II MARCH MOUNTAIN lI I I MARCH PPERMTIEOSU,NTL IC OZONING: 1 i PR55E-01-2N25 IMP _- f I - _ PROPERTIES, LLC I 0 USE VACANT USE: VACANT III 55E-01-- ZONING. NMD TMP 27-9 _— ZONING NM - - - - - CURVE RADIUS ARC LENGTH C-CL 1 37.00' 28.09' C-CL2 1608.95' 130.74' CHORD LENGTH CHORD BEARING DELTA ANGLE 27.42' S 08'50'34" E 43'30 20.33" 130.70' S 28'17'28" E 4'3920.71" SIGN LEGEND MUTCD // DESCRIPTION REMARKS o$4�PLT OF Dl�c FILE NUMBER R1-1 "STOP" SIGN 30"X30" r ^ 8053 CINE BEARING DISTANCE WIS] 5 60'06'19" W 61.48' R7-1 "NO PARKING" SIGN 12"X18"✓ NOTE: o Ji �1y L T ft LIc. N ALL SIGNS SHALL BE IN ACCORDANCE WITH THE CURRENT VERSION OF THE MUCTO AND THE VIRGINIA SUPPLEMENT TO THE MucrD C, 90 22841 `� Fessl OryA E�Gl 30 SCALE 1"=30 0 30 60 SHEET SCALE IN FEET , 3 Of 10 0 n=,=l F, ­'li 1- 1 - I 1p[l - "l-1111 11,111, - -1-1, - " I- .,,I 11 , " /111 N�l k, 0 22 0 �d r \\\ -- — a W • Lu Z MARCH III g77 A, I W111111 PROPERTIES, 15111111, "1 IMP 55E -01 -JA -1 ­ IT -- J, QJ Ev. USE POOL j NING—Nbe- 110 7:7�� . , , -o q iv JA-ZAN LLC IMP 11,11-11-A USE VACANT Or. L EX. 6-A, Jk\ '. �' ZONING: AMD WO drnN YWrnN WO 2�n�� 2N \ �\ OZ � � - -- 24'nN W4R'nN I� W p 4�1N J -:Y UWjK? Ilk O r4 ------ 0 EX. Al EZ OLD TRAIL DRIVE 694 F_ REVISIONS 77 PUBLI _W OR 2336-PGCIJf?4 -pROP PU5-11 ESMY 03/2812018 EX COUNTY COMMENTS L MARCH MOUNTAIN PROPERTIES, LLC IMP 55E -01-7B USE. VACANT ZONING: NMD � ----------- 05/0212018 COUNTY COMMENTS DB 4954 PG 18 26 25 24 22 (21 2 19 SAN. FUTURE COMMERCIAL LAT. IAICEL P 5h 8'X6" TEE, 6" CV, PH /,q (TYP. S LAT� PROP. PRIV. TRIM .25' HB ES 4" G�, 1. DOM W/ _�CE METER VAULT REMOVE 'OOV, EXTEND 8" W/L DATE JAN. 12, 2018 8" GV. 8" PLUG PROP. WATER ESM F SCALE X. T EA SAN E_�,f'T E 3 EMP. STORM LIS 5— FG DRAINAGE ESM'T. DE D31 PC 77 678 I�T 421 -PRO'. sw MAI FENANCE ESM 1.18 9 EV IITIL� 14- 16 17 < Hole- ESM'T. V 5,124 PC2A_0I FUTURE PARKING AREA Lu CONTOUR INTERVAL FEET B11 682.5 q MOUNTAIN PROPERTIES, LLC PROP. MARCH �P SEDIMENT TRAP IMP 55E -07-7A USE, VACANT T 7L 7L 7L- 7L Fl F�j Z < ��d 2 __j m (SEE EROSJON CONTROL ZONING AMD • PLAN FOR DESIGN DETAILS DB 4954 PG 16 % WPO -2018-00008) MF �2100 z • I:NWE '17+00 1115 - EX. SEW.- 7 CL i i+f C-AE:WT 400; PC J59 <M`/ t qL vv F 11111.\ESM LIS 50'4 P,C 5 Lu J w MARCH MOUNTAIN PROPERTIES, LLC 12 11 0,/ �,_:Am�Q') QlkIMP 55E-01-350 USE, VACANT EX. ZONING.- NUD T- (L EL Z _T_ Fx- t 684 - 'Ti�Al w7 - A21 P( �2A EX. Z) CC 0 EX. lEx BENCHMARK RK Ex ORION LANyf E: 61' PUBLIC Row (90 Top STM.INL­ 682.30 F, 1 W,'L _PG 389 Dj 47074 Y EYE �o 0 L V" 19 - - - - - - - CRAIG ENTERPRISES INC IMP 55E-01-27-5 --- - -------- MARCH MOUNTAIN EX- MOUNT IN ��P'1'12ERTIESL USE ,,,RESIDENTAL -IT' 4 "'I'TH OpDf LEGEND FILENUMBER 80 :5M3 STEEP SLOPES (MANAGED) J* d, L. T U.. N.. SCALE 1 -30' 22841 41 O� "1 30 NSIONAt 0 30 60 SHEET SCALE IN FEET 4 Of 10 0 n=,=l F, ­'li 1- 1 - I 1p[l - "l-1111 11,111, - -1-1, - " I- .,,I 11 , " /111 j \R '-A', TMPiS,1105.—DLD I K I I0,6 11C 1� 7',P � --\Fi,.,i I P I ;: 7 -Ph-- 2 F,,,, I P I,;, J, . 5/ /2U 1,- 3: -1 -, \1 \.-,ani ,, FENNEL ROAD OLDHAM DRIVE SANITARY SEWER PROFILE PVI STA. 11+86.16 EX w PVI ELEV. 687.46 PVI STA. ELEV12+00.00 _ K = 146.77 700 L O R W O o- i N y 4 7 �I 2mQ 700 695 695 700 700 O U z O u 0 F0 cc O 22Q 2W 5O J OU �z az 695 690 690 695 695 Z � - {CID 5; Q U¢ FW �o W Q 2U 690 685 685 690 690 0 W ct WO OR �.�.I r� IL? 0 L 685 _ 680 680 6851 685 rlil y ¢ U 1�+ a y Lu I 2 I W ¢ " Z �z 680 675 675 6801 680 p x O/ W a 675 670 670 675 675 w REVISIONS of 03/28/2018 670 665it 665 670, 670 COUNTY COMMENTS 08/02/2018 Z COUNTY COMMENTS 665 660 660 665 `'' 665 0 0 0 Horizontal + Vertical 660 O 660 F�s910NAi. E�Gl - - roU U .n v o b ro b io t0 io t0 .in .n b U � U 11+75 12+00 +254 +504 +754 13+00 +25 +50 +75 14+00 +25U +50 +75 11+00 +25 +50 +75 12+00 10+00 +25 +50 +75 11+00 +25 +50 +75 DATE JAN. 12, 2018 SCALE H:1°=25' Ex Ex. 5 -5A 3 7 8 9 8 is CONTOUR INTERVAL N/A to 700 700 695 695 695 695 695 695 690 690 690 690 //NZ� 690 690 685 685 68 685 Lu VJ g Q z �Q J¢ W=�� J EL =1 685 J 685 680 680 680 680 I J On�Q� a�1dSI 680 680 675 675 675 675 U OMM Q Q 675 670 670 670 670 W J s7s Q 670 670 665 665 665 665 t__ � L 665 665 660 660 660 660 FILE NUMBER 0 to 11 8053 660 660 655 655 655 655 SHEET 0+00 +25 +50 +75 1+00 +25 +50 +75 2+00 +25 +50 +75 0+00 +25 +50 +75 1+00 +25 +50 +75 2+00 +25 0+00 +25 +50 FL, 6 of 10 HIGH PT. ST�t. 12+07.5 HIGH PT. EI�EV. 690.06 K = 62.55 250. 0 VC o �n 700 N � o M �> w W J d Nw 695 ... Fw a o- — 690 II 3.5' MIN CL 5 685 SCALE 1"=25' (HORIZONTAL) 1 5,� 5 0 25 50 W NP. W/ SERVICE CMIEAR o' CONNECTIONS 1" CORP. 15" SCALE IN FEET 680 " 8i0P (s E DETAIL) STM. XING. SCALE 1 "=5' (VERTICAL) 5 y + 675 2.5 v � m � � � X w Z � � ~ SCALE ON FEET 670 z w _ O Z � O O� t.TH OF z > O N Gr w m m o cr 665 _..__m o_ EXISTING GRADE CL � `r w � 7 J •j '� w of PROPOSED GRADE CL ~ . J. ­­ N rn ro a 0 N o_ m a o N a m a � X W 0 ro rnm 0 W Q W F W �a 5a o_ a II � _ ® 1.00% 1 .98% - 15 �I I a ®4 5 io J m N I a m N � I � ro Irn — —EXISTING GRADE CL o �j g^ HDPE o �j row° m � w PROPOSED GRADE CL + 59 4 3 z n Z O 201.6' - 18" HDPE � V O +> Horizontal Scale = t 25 O » +» t- Vertical Scale = 1 5 Vl O zz p O Z U 0_ r N � o o + z _ro f- w " w m Z —EXISTING GRADE CL r r W W W PROPOSED GRADE CL co r FUTURE GRADE CL 0 O W Z W I Scale = 1 :5 a � rn m -o O w � d" co I I � � II —EXISTING GRADE CL w � o F o II II � I m z m pZ ZO O O � co -O o+»> z z z Horizontal Scale = 1 25 Vertical Scale N > N» + FUTURE GRADE CL rn + x � Niy L Tpggart uo. No. Horizontal Scale = 1 25 n � �o 22341 Vertical Scale = 1 5 '- N rn ro a 0 N o_ m a o N a m a � X W 0 ro rnm 0 W Q W F W �a 5a o_ a II � _ ® 1.00% 1 .98% - 15 �I I a ®4 5 io J m N I a m N � I � ro Irn — —EXISTING GRADE CL o �j g^ HDPE o �j row° m � w PROPOSED GRADE CL + 59 4 3 z n Z O 201.6' - 18" HDPE � V O +> Horizontal Scale = t 25 O » +» t- Vertical Scale = 1 5 Vl O zz p O Z U 0_ r N � o o + z _ro f- w " w m Z —EXISTING GRADE CL r r W W W PROPOSED GRADE CL co r FUTURE GRADE CL 0 O W Z W I Scale = 1 :5 a � rn m -o O w � d" co I I � � II —EXISTING GRADE CL w � o F o II II � I m z m pZ ZO O O � co -O o+»> z z z Horizontal Scale = 1 25 Vertical Scale N > N» o m m ti) ro r of rn m co co a a o O O 15" STM. G. 1.5' CLEAR - -26 82. _ g" SDR 77.9' - o � �g O oro^ a a� h� N fnvo0i m c^o II � O �? o —EXISTING GRADE CL p » PROPOSED GRADE CL ro II r- zzz =o rozo ro m - > w w + > Horizontal Scale = 1 25 + > > z o z Vertical Scale = 1 5 N o_ N a 0 ro rnm 0 Q W F W �a 5a o_ a � 2 ® 1.00% 1 .98% - 15 a N io J m N I a m N � I � ro Irn — —EXISTING GRADE CL o �j w Z 5 o �j row° m � w PROPOSED GRADE CL + 3 z n Z O z � V O +> Horizontal Scale = t 25 O » +» t- Vertical Scale = 1 5 Vl O zz p O Z U 0_ r N � w o + z w " w m Z —EXISTING GRADE CL c00o PROPOSED GRADE CL co r FUTURE GRADE CL � ntel Scale = 1 :25 I Scale = 1 :5 o m m ti) ro r of rn m co co a a o O O 15" STM. G. 1.5' CLEAR - -26 82. _ g" SDR 77.9' - o � �g O oro^ a a� h� N fnvo0i m c^o II � O �? o —EXISTING GRADE CL p » PROPOSED GRADE CL ro II r- zzz =o rozo ro m - > w w + > Horizontal Scale = 1 25 + > > z o z Vertical Scale = 1 5 N o_ N a 0 0 92.0' HPE ® 1.00% 127.1• - 15 io J m N I a m N � I � ro Irn — —EXISTING GRADE CL o �j ,� m�O o �j row° � oo? PROPOSED GRADE CL �D O O N Z O Z O +> Horizontal Scale = t 25 + » +» oZ Vertical Scale = 1 5 zz �zz O 0 0 8" WL XING. 1.5 CLEAR MIN. -� 1.5 3s.T - CLEAR t�" E MIN ® 2.32 8" AN. ING. J J m m oro ro� o� Orn rno o� ro O II II II 0o II IIS �� O Z Z O � O oz zz oz 0',F,.-,a\.TrnFeuJ`. -- -r,,_o TFAiu,errrr.. 7\P1.,., zv[,, i Fn- `,e,n:.� 7 -Ph, - " F jai PI -d-, -16 14 rr,i. ,c „ N o_ N a 0 0 92.0' HPE ® 1.00% 127.1• - 15 io J m N I a m N � I � ro Irn — —EXISTING GRADE CL o �j ,� m�O o �j row° � oo? PROPOSED GRADE CL �D O O N Z O Z O +> Horizontal Scale = t 25 + » +» oZ Vertical Scale = 1 5 zz �zz O 0 0 8" WL XING. 1.5 CLEAR MIN. -� 1.5 3s.T - CLEAR t�" E MIN ® 2.32 8" AN. ING. J J m m oro ro� o� Orn rno o� ro O II II II 0o II IIS �� O Z Z O � O oz zz oz 0',F,.-,a\.TrnFeuJ`. -- -r,,_o TFAiu,errrr.. 7\P1.,., zv[,, i Fn- `,e,n:.� 7 -Ph, - " F jai PI -d-, -16 14 rr,i. ,c „ 0',F,.-,a\.TrnFeuJ`. -- -r,,_o TFAiu,errrr.. 7\P1.,., zv[,, i Fn- `,e,n:.� 7 -Ph, - " F jai PI -d-, -16 14 rr,i. ,c „ i MANDATORY INSPECTIONS AT THE FOLLOWING PHASES ARE REQUIRED FOR ROADS THAT ARE PROPOSED TO BE STATE MAINTAINED, OR PRIVATE STREETS THAT ARE TO BE ACCEPTED BY ALBEMARLE COUNTY: 1. INSTALLATION OF ANY ENCLOSED DRAINAGE SYSTEM BEFORE IT IS COVERED. 2. INSTALLATION OF ANY ENCLOSED UTILITY PLACEMENTS WITHIN THE RIGHT-OF-WAY BEFORE BEING COVERED. 3. CONSTRUCTION OF THE CUTS AND FILLS, INCLUDING FIELD DENSITY TESTS, BEFORE PLACEMENT OF ROADBED BASE MATERIALS. 4. A FINAL PAVEMENT DESIGN, BASED ON ACTUAL SOIL CHARACTERISTICS AND CERTIFIED TESTS, SHALL BE COMPLETED AND APPROVED BEFORE THE PAVEMENT STRUCTURE IS PLACED. 5. PLACEMENT OF BASE MATERIALS, INCLUDING STONE DEPTHS, CONSISTENT WITH THE APPROVED PAVEMENT DESIGN. PRIOR TO PLACEMENT OF THE PAVING COURSE OR COURSES, FOLLOWED BY FIELD DENSITY AND MOISTURE TESTS AND THE PLACEMENT OF A PAVING COURSE AS SOON AS POSSIBLE. 6. CONSTRUCTION OF PAVEMENT, INCLUDING DEPTH AND DENSITY, UPON COMPLETION AS PART OF THE FINAL INSPECTION. 7. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING VDOT A MINIMUM OF ONE WEEK PRIOR TO EACH OF THE ABOVE PHASES OF CONSTRUCTION TO SCHEDULE AN INSPECTION. 8. FAILURE OF THE CONTRACTOR TO SCHEDULE THESE INSPECTIONS WILL REQUIRE ADDITIONAL TESTING OF THE ROADS AT THE DISCRETION OF VDOT OR MAY LEAD TO, THE ROADS NOT BEING ELIGIBLE FOR STATE MAINTENANCE. Upstream Structure CC -2 NOTES[ Total Flow (cfs) Upstreaminvert (ft) 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE, Length (ft) Z 2. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, Manning's n Maximum Flow (cfs) 4000 PSI IF PRECAST. 4 PS PERMANENT 3. CURB HAVING A RADIUS OF 300 FEET OR LESS IPLONG FACE OF CURB) WILL BE PND FOR PS EX/ST/NG GROUND SEED/NG - 3 3 RADIAL CURB. 0.5 2.92 p, THE DEPTH OF CURB MAY BE REDUCED AS MUCH '• 97.50 115" DEPTH) OR INCREASED PS MUCH AS 3" (21" DEPTH)IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A '• m COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE. THE DEPTH IS TO BE 18" AS SHOWN. a 3.72 3.72 NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE IN DEPTH, d' d D� ' p�- ° p SURFACE 6 CG -2 1S TO BE USED ON ROADWAYS MEETING 0.000 0.50 THE REQUIREMENTS FOR CG -6 AS SHOWN IN APPENDIX A OF THE VDOT ROAD DESIGN MANUAL, IN THE SECTION ON GS URBAN STANDARDS. o. e, 675.44 177.30 2.34 18 0.013 8.04 BASE 8.85 677.85 671.80 6-7 6-6 0.220 2" RADIUS ° SUBBASE I I 172.20 1.07 d. 6.. 5.11 BE DOe T D. SURFACE d. d. . 6.03 681.49 D 6-6 6-5 A' BASE 0.85 1.35 SUBBASE 681.43 161.10 6" 18 0.013 12" 5.88 5.88 ACCEPTABLE ALTERNATIVE 681.90 6-5 IF CURB IS EXTRUDED 0.000 0.50 SPECIFICATION 685.90 684.78 `VDOT REFERENCE STANDARD 611 CURB 0.013 ROAD AND BRIDGE STANDARDS I05 REVISION DATE I SHEET 1 OF 1 502 VIRGINIA DEPARTMENT OF TRANSPORTATION 6-3A 201.01 MANDATORY INSPECTIONS AT THE FOLLOWING PHASES ARE REQUIRED FOR ROADS THAT ARE PROPOSED TO BE STATE MAINTAINED, OR PRIVATE STREETS THAT ARE TO BE ACCEPTED BY ALBEMARLE COUNTY: 1. INSTALLATION OF ANY ENCLOSED DRAINAGE SYSTEM BEFORE IT IS COVERED. 2. INSTALLATION OF ANY ENCLOSED UTILITY PLACEMENTS WITHIN THE RIGHT-OF-WAY BEFORE BEING COVERED. 3. CONSTRUCTION OF THE CUTS AND FILLS, INCLUDING FIELD DENSITY TESTS, BEFORE PLACEMENT OF ROADBED BASE MATERIALS. 4. A FINAL PAVEMENT DESIGN, BASED ON ACTUAL SOIL CHARACTERISTICS AND CERTIFIED TESTS, SHALL BE COMPLETED AND APPROVED BEFORE THE PAVEMENT STRUCTURE IS PLACED. 5. PLACEMENT OF BASE MATERIALS, INCLUDING STONE DEPTHS, CONSISTENT WITH THE APPROVED PAVEMENT DESIGN. PRIOR TO PLACEMENT OF THE PAVING COURSE OR COURSES, FOLLOWED BY FIELD DENSITY AND MOISTURE TESTS AND THE PLACEMENT OF A PAVING COURSE AS SOON AS POSSIBLE. 6. CONSTRUCTION OF PAVEMENT, INCLUDING DEPTH AND DENSITY, UPON COMPLETION AS PART OF THE FINAL INSPECTION. 7. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING VDOT A MINIMUM OF ONE WEEK PRIOR TO EACH OF THE ABOVE PHASES OF CONSTRUCTION TO SCHEDULE AN INSPECTION. 8. FAILURE OF THE CONTRACTOR TO SCHEDULE THESE INSPECTIONS WILL REQUIRE ADDITIONAL TESTING OF THE ROADS AT THE DISCRETION OF VDOT OR MAY LEAD TO, THE ROADS NOT BEING ELIGIBLE FOR STATE MAINTENANCE. 4" 3000 PSI "'" CONCRETEII I VDOT ST'D 114": 1' 0 IS I I N 4" 3000 PSI CONCRETE �1-1�1=1�1-1�1�1II� ..�.-_':, +..>^:cz;.-.__:+.:;•r;e�:�,.,:"'` I�L�1I1-1I1�1I1-1�I� - -III-IIIIIIII III III I III -III II - 4 vgoT 2fa All III III nl III STONE BASE TYPICAL SIDEWALK SECTION N.T.S. Face of Cure `j�� Invert une uN //- Face of Curb a I � .T. TX. Rofflop Curl) Curb Std. CG -6 N.T.S. N.T.S. Source: VDOT Road Design Manual, Appendix B Source:: VDOT Road Design Manual, Appendix B 5' TRANSITION EDGE OF PVIMT./ GUTTER PAN ROLLTOP FACE OF CURB CURB FACE OF DI _3 BACK OF CURB BACK OF _ CURB CURB ROLLTOP TO CG -6 TRANSITIONS THE FOLLOWING NOTES APPLY TO CG -6, CG -7, AND ROLL-TOP CURB: 1. CURB AND GUTTER MAY BE PRECAST OF CLASS A4 HYDRAULIC CEMENT CONCRETE OR CAST IN PLACE USING CLASS A3 HYDRAULIC CEMENT CONCRETE. 2. WHEN USED WITH STABILIZED, OPEN -GRADED DRAINAGE LAYERS, THE BOTTOM OF THE CURB AND GUTTER SHALL BE CONSTRUCTED PARALLEL TO THE SLOPE OF THE SUB -BASE COURSES AND TO THE DEPTH OF THE PAVEMENT BUT NOT LESS THAN THE THICKNESS SHOWN. STORM SEWER COMPUTATIONS ADT PLAN N.T.S. Downstream Structure Upstream Structure Area (Acres) Runoff Coef. Total Flow (cfs) Upstreaminvert (ft) "INING Length (ft) Z Pipe Size (in) Manning's n Maximum Flow (cfs) Upstream Velocity (fps) Downstream Velocity (fps) PS PERMANENT AF TO EXISTING GROUND, TYP. EX/ST/NG GROUND SEED/NG - 3 3 0 0.5 2.92 675.09 B/M 97.50 TREATMENT 1 V - DITCH 0.013 4" 3000 PSI "'" CONCRETEII I VDOT ST'D 114": 1' 0 IS I I N 4" 3000 PSI CONCRETE �1-1�1=1�1-1�1�1II� ..�.-_':, +..>^:cz;.-.__:+.:;•r;e�:�,.,:"'` I�L�1I1-1I1�1I1-1�I� - -III-IIIIIIII III III I III -III II - 4 vgoT 2fa All III III nl III STONE BASE TYPICAL SIDEWALK SECTION N.T.S. Face of Cure `j�� Invert une uN //- Face of Curb a I � .T. TX. Rofflop Curl) Curb Std. CG -6 N.T.S. N.T.S. Source: VDOT Road Design Manual, Appendix B Source:: VDOT Road Design Manual, Appendix B 5' TRANSITION EDGE OF PVIMT./ GUTTER PAN ROLLTOP FACE OF CURB CURB FACE OF DI _3 BACK OF CURB BACK OF _ CURB CURB ROLLTOP TO CG -6 TRANSITIONS THE FOLLOWING NOTES APPLY TO CG -6, CG -7, AND ROLL-TOP CURB: 1. CURB AND GUTTER MAY BE PRECAST OF CLASS A4 HYDRAULIC CEMENT CONCRETE OR CAST IN PLACE USING CLASS A3 HYDRAULIC CEMENT CONCRETE. 2. WHEN USED WITH STABILIZED, OPEN -GRADED DRAINAGE LAYERS, THE BOTTOM OF THE CURB AND GUTTER SHALL BE CONSTRUCTED PARALLEL TO THE SLOPE OF THE SUB -BASE COURSES AND TO THE DEPTH OF THE PAVEMENT BUT NOT LESS THAN THE THICKNESS SHOWN. STORM SEWER COMPUTATIONS ADT PLAN N.T.S. Downstream Structure Upstream Structure Area (Acres) Runoff Coef. Total Flow (cfs) Upstreaminvert (ft) Downstream l nve rt (ft) Length (ft) Slope M Pipe Size (in) Manning's n Maximum Flow (cfs) Upstream Velocity (fps) Downstream Velocity (fps) Upstream HGL (ft) Downstream HGL (ft) 6-9 6-8 0 0.5 2.92 675.09 672.32 97.50 2.84 18 0.013 8.42 3.72 3.72 671.08 670.40 6-8 6-7 0.000 0.50 2.82 679.58 675.44 177.30 2.34 18 0.013 8.04 8.85 8.85 677.85 671.80 6-7 6-6 0.220 0.85 2.35 681.43 679.58 172.20 1.07 18 0.013 5.11 6.03 6.03 681.49 679.23 6-6 6-5 0.290 0.85 1.35 684.73 681.43 161.10 2.05 18 0.013 6.03 5.88 5.88 685.52 681.90 6-5 6-3A 0.000 0.50 0.43 685.90 684.78 201.60 0.56 18 0.013 4.71 3.54 3.54 688.41 685.97 6-3A 6-3 0.070 0.94 0.37 688.70 686.00 59.60 4.53 18 0.013 2.22 1.98 1.98 689.11 689.10 STORM SEWER COMPUTATIONS Downstream Structure Upstream Structure Area (Acres) Runoff Coef. Total Flow (cfs) Upstream Invert (ft) Downstream Invert (ft) Length (ft) Slope I%) Pipe Size (in) Manning's n Maximum Flow (cfs) Upstream Velocity (fps) Downstream Velocity (fps) Upstream HGL (ft) Downstream HGL (ft) 7 8 0.090 0.85 2.08 680.85 679.48 127.1 1.08 15.00 0.013 6.97 4.70 4.70 682.80 680.58 8 9 0.030 0.95 0.59 681.87 680.95 92.0 1.00 15.00 0.013 6.98 3.28 3.28 682.83 682.27 9 FLIT. INLET 0.070 0.90 0.42 682.55 681.97 57.9 1.00 15.00 0.013 6.97 2.97 2.97 682.98 682.97 8 19 0.220 0.90 1.07 681.80 680.95 36.7 2.32 15.00 0.013 10.60 5.26 5.26 683.02 683.01 INLET SEWER COMPUTATIONS Structure # Area Runoff Coeff Flow Long. Sloe Spread Gutterwidth/ spread V DOT Ch. 9, App. 9C- 8 Equivalentcross sloe Throat Length Re 'd to et 100% Depth Throat Length A(ac) C Q(cfs) S(ft/ft) T(ft) WIT Eo Se(ft/ft) Lt(ft) d(ft) (ft) 8 0.09 0.85 0.31 0.01 4.40 0.454 0.90 0.10 4.65 0.22 6 9 0.03 0.95 0.11 0.01 3.04 0.658 0.95 0.10 3.00 0.19 4 19 0.22 0.90 1 0.79 0.01 6.29 0.318 0.80 0.09 7.33 0.26 8 34' PRIVATE R/W 114": V POINT OF \ FINISHED SURFACE ROLLTOP GRADE 1.5" SM -9.5 CURB �-- 1/4": V 114' i'--► BASE SUBBASE 2.5" BM -25 6" AGGREGATE(21A) 10' 711 II I I 10, 5' 0,5' PARKING LANE TRAVEL LANE TRAVEL LANE CONCRETE SIDEWALK 20' 14' TYPICAL SECTION FENNELROAD PRIVATE STREET (25 MPH DESIGN SPEED) (STA. 12+41 TO STA. 13+81) N.T.S. 30' PRIVATE R/W TYPICAL SECTION FENNELROAD PRIVATE STREET (25 MPH DESIGN SPEED) N.T.S. 1 24' PRIVATE R/W >4": 1' 1 1/4% V ROLLTOP SURFACE ROLLTOP \ CURB 1.5" SM -9.5 CURB --1/4" 1' 114- : V ->- BM -25 1 6' AGGREGATE(21A) 2' 1i TYPICAL SECTION OLDHAM DRIVE PRIVATE ALLEY (25 MPH DESIGN SPEED) N.T.S. 1 �2 y N N D Q. oy zo U 2Q Q� ic5 O v) a2 � W p Zia OW Wa " LL U� W 20 Ed (6 go4 LU W aN Y W Z Z a OW® REVISIONS 03/28/2018 COUNTY COMMENTS 05/02/2018 COUNTY COMMENTS JAN JAN. 12, 2018 SCALE AS SHOWN CONTOUR INTERVAL N/A J 06cgZ( fnW5gwNa Z �Q J¢ o=-> Z n- > z Zn�Q� POO WOao� J J°°CC0 U a FILE NUMBER 8053 SHEET 7of10 U:\PI;A', Tf:IFP�JI\'115�-OLD TF:ILIBII ' , 7'1,Fh Use,-\Fir.,.l Flu n`,c l:,c,: 7 -Tho=s Fi­l Flan.dv.; ..i.01'. 3:-,F:39 PM. A -'.\F TLIPr, D T¢'IL E,' 1. ]\PIT, _e _',. FILL I FI-I\BI-d ]-Ph- ' rn.TI FI T.dea �/°/SIT 1c [F AS P'J. A,an:.v ' , PB -1 GENERAL PB= NO PROJECTION OF PIPE ABOVE GROUND LINE Is 1 r 1 a �•/ 1. METHOD "A" PIPE BEDDING SHALL BE USED FOR ALL TYPES OF PPE CULVERTS WITHIN THE APPLICABLE HEIGHT OF COVER RANGE NOTED IN THE STANDARD PC -1 TABLES UNLESS NOTED ON THE PLANS W ° LO 0 OTHERWISE 2 H • HEIGHT OF COVER MEASURE➢ FROM TOP OF CULVERT TO FINISHED GRAPE. 3 6 EXCAVATION DEPTH AS SHOWN ON ALMS OR TO FIRM BEARING SOIL. CIRCULAR PIPE 1 0 OUTSIDE DIAMETER OF PIPE.' 4 E ��T IIT III III - Inl b U -III d J III I�71�1' IHII - ILII L A EAR H%SHME �/ isi j� SHARE TO ELEVATION of Mo -POINT OF LARGEST PIPE. N = f�l Z Q NO E _ SII 'J III T N IDIII - 9 - / `GAR -H 3 III 2. d INSIDE DIAMETER OF PPE. 5 LE - IIF. ��� T G MA�ER'AL TO CONTOUR OF PIPE VVVIII Q Ml 3. X WDTIT OF CLASS I BACKFILL MATERIAL BEYOND THE EXTREMITY OF THE PIPE. . 12 WHERE d IS LESS THAN 36". X . 1B" WHERE d IS 36" AND GREATER. J .- : L� J ! I� v MN. SIT �r — ° /10 p " , 10 D c ./ �, T� Mw. 1/ _ _ - I Z O (9 Q U �j a 1` ¢ /.h �Ql 4. WHERE DIRECTED BY THE ENGINEER. BEDDING MATERIAL MAY BE ELIMINATED FOR NORMAL EARTH FOUNDATIONS UNDER ROUTINE ENTRANCE PIPE (EXCEPT PLASTIC PIPET 30" AND LESS IN DIAMETER WITH HEIGHT OF COVER 15'OR LESS. p BpODIRN<u x !`^- MD x _ MATEFIAL 'Mi'XPER i OF 11 "' B' RIA%' 2n 4 D x I I O C W S LL 5. REGULAR BAGKFILL MATERIAL MAY BE USED IN LIEU OF CLASS I BACKFILL MATERIAL FOR AILUNDATION TYPES FOR ROUTINE ENTRANCE PIPE (EXCEPT PLASTIC PIPE)Zi AND LESS IN DIAMETER WITH HEIGHT OF COVER 15' OR LESS. 6. BEDDING MATERIAL AID CLASS BACKFILL MATERIAL MAY BE ELIMINATED FOR SHOULDER NORMAL EARTH FOUNDATION ROCK FOUNDATION FOUNDATION SOFT, YIELDING, OR OTHERWISE UNSUITABLE MATERIAL �// a Z O N W PIPE PROJECTION ABOVE GROUND LINE SLOT INLET (D 13) OUTLET PIPES NSTALATIONS. " W +D of FLL Top— M N. i.5 . D M - >, D - _ — - — d GRDVND ELLIPTICAL PIPE 1. Si OUTSIDE SPAN DIMENSION OF PIPE. 2 52 • NEE SPAN DIMENSION OF PIPE. 3 R - ouislDE RISE DIMENSION of PPE. 4. X WITH OF CLASS (BACKFILL "Ill BEYOND THE EXTREMITY OF THE PIPE. ERE 52 IS LESS THAN 36'. - 10" WHERE S22 IS 36 MO GREATER 5. WHERE DIRECTED BY THE ENGINEEfl. BEDDING MATERIAL MAT BE ELIMINATED FOR �% y = �� TRANSITION BETWEEN PIPE DIAMETERS WHEN DIFFERENT SIZES OF EREO. PIPES ARE ENCOUNTER G INVENT OF OUTLET°PPE T SECTION A-ACc METHOD OF TREATMENT IN DROP INLETS //\�� O � 0 2 J W O I U' "y i• 0 Q W \ i h Q Q _ d `ft ELND LORMAL EARTH FOUNDATIONS UNDER ROUTINE ENTRANCE PIPE WHERE S2 IS 38" OR ESS AND HEIGHT OF COVER 15 OR LESS. fi REGULAR BACKFLL MATERIAL MAY BE USED LEU OF CLASS IBACKFIO_ MATERIAL FOR ALL FOUNDATION TYPES FOR ROUTINE ENTRANCE PIPE WHERE S2 IS 38 OR LESS AND HEIGHT OF COVER 15'OR LESS. PIPE ARCH " ( J �-' JJIJ III II - Fi/ MIN - ✓ D % . 1/10 D MATER AL H / 1 1111-7, Y ROCS OR it J _III- "�� L re \ —CEOODNp"y Max. 2a M _. - L NL M / T / / / '�'' /-_ M' t/td MATERIAL ART( NOTES: HAPNG OF MANHOLE AND INLET INVERTS IN ACCORDANCE WITH THIS DRAWING IS TO MALT TO THOSE STRUCTURES SPECIFIED j ON PLANS OR WHERE INVERT OF PPE 5 ABOVE INVERT OF STRUCTURE. E OR DROP INLET 5 TO BE FORMED AND CONSTRUCTED / MMHCCRCMCE A, �� \ SLOPE TO INVERT OF OUTLET PIPE J ul ? OJJ J 1 vM Q� W N/I H O W 1 E - SPAN DIMENSION of PIPE. 2. R . RISE DIMENSION OF PIPE NORMAL EARTH FOUNDATION ROCK FOUNDATION FOUNDATION SOFT, YIELDING, OR OTHERWISE UNSUITABLE MATERIAL WItH APPLICABLE STANDARD OR SPECIAL DRAWING. poarin.AVES SHARING AS DEFE L1%coNF°o"aMlucTOo00ciAss AG3F OR CLASS CI.EXCSET THAT 2U OF COARSE AGGREGATE MAY BE /� a ,,/// W Q 1 W p BEDD`1, MATERIAL N tlaNKMErvi SP HE �0°RAD BR BRIDGE L'ry NOTES; A �C LAN T rH GL IaAL :1 - uN 1 B la S iCRIALDMiIIC AG C SEE INSi AILAt ON `F PTFE LL'UVIf ® .1- FEABIODIK302 DF THE ROAD AND BRIDGE AND SEORM SEWERS GENERAL NOTES SPECT 3. 8 - SEE PC -1 TABLE FOR APPLICABLE PIPE MATERIAL 4. z WIDTH OF CLASS (BACKFILL MATERIAL BEYOND THE EXTREMITY OF THE PIPE. x• 2" WHERE 52 IS LE55 THAN 36". • 1B" WHERE 52 IS 36" AND GREATER UP TO 4' IN DIAMETER AND CONSIST OF BRICK. I BROKEN CONCRETE OR BROK'.EN CONCRETE Si.BLOCK. THE SURFACE E LEFT SMOOTH BY MEANS OF HAND TROWELLING. NONE OF THE COAREE AGGREGATE SHALL REMAN EXPOSES. DETAILS OF INVERT SHARING AS SHOWN HEREON ARE FOR E%AMPLE _— %/ A' �y' n 2 Z O 2 a, 5. WHERE DIRECTED BY THE ENGINEER. BEDDING MATERIAL MAY BE ELIMINATED FOR NORMAL EARTH FOUNDATIONS UNDER ROUTINE ENTRANCE PIPE WHERE S2 IS 35" OR LESS AND HEIGHT OF COVER SIR OR LESS. 6. REG LM BACKFILL MATERIAL MAY BE USED IN LIEU OF CLASS I BACKFILL MATERIAL FOR FOR ENTRANCE PIPE WHERE S S 35" OR LESS AND ,, _ ON STEEL IOI.00. F'Li uL OF THE ROAD AID FANDCE CL SS I B r F auSnED 55 NFOORMING T THE NU SPE I HUT Oi SIO:IA302 UOFMiITiERROAD SVEA61CAi10N5. NI RCATER IMZEV 21 FOR Ihl AG R BICE' _ PURPOSES ONLY. EACH MANHOLE OR DROP INLET IS TO BE SHARED INDIVIDUALLY TO BEST FIT THE PARTICULAR INLET AND OUTLET CONFIGURATION AND FLOW EWES. PLAN SECTION B -B W O ALL FOUNDATKIN TYPES HEIGHT of COVER R F HER ALL UTHOF P1FF REGULAR BALDNIL MATERIAL _Seo 'r' PLACE of GLASS T BA1." IL" ACCDIIAIE W 302 OF THE ROAD D BRIDGE SPECIFICA:i1G1yiI0N AVDDT METHOD OF TREATMENT IN MANHOLES SPECIFICATION REFERENCE INSTALLATION OF PIPE CULVERTS & STORM SEWERS ROAD BRIV D�SANDMOS INSTALL. OF PIPE CULVERTS AND STORM SEWERS '1EFIER°NT°" VDO-r ROAD Mo BRIDGE STANDARDS STANDARD METHOD OF SHAPING MANHOLE &INLET INVERTS RECTIFICATION REFERENCE 3oz 303 REVISION DATE SHEET i OF 1 R°A "'° B RI -E STANDARDS 5t1EEiH1 DATE 302 REVISIONS GENERAL NOTES CIRC. PIPE BEDDING AND BACKFILL - METHOD „A„ EmsoN Dare VIRGINIA DEPARTMENT OF TRANSPORTATION tOJ.00 303 DEPARTMENT OF TRANSPORTATION 03/28/2018 - _ CC 1z A —� •5 SCRELS S LONG -I PERMSSE E gti�/- AT tz c c, 5,M �Jor Ta cr ory A MN 9f A c CS PERM sRs eLi oN� ss5 DOWEL 9 LONG m 12 C L sL-i #s BMs a a" C -c TVP. .". •. : I LL I I I L I •• os Ba¢s 8 C -C iYP. COUNTY COMMENTS 05/02/2018 COUNTY COMMENTS d¢IN 0� WITH BUFFER STRIP B I Gt B ,( _I A I I I I I I A .-FT-T-7- ( 30'• DIANETEft J I I It— x:21--"-"` y. NUN5� MLE1 A 1'A`1' SEE ATE° °oFEs F°re pETAILS — =\ - TYPICAL DESIGN A— SEE"SHEETS OF 5 '; I I I I I I I ..: I T A, CURB OF aA GF CURBWITH BUFFER STRIP - 1F KGo FAIR OF B _( �L•'�"• 1r11 DATE JAN. 1Z, ZO1$ - AS'`"N � STRUCTURE SIZE AND �, �PLAN WALL THCRNEES 1ARES PLAN MA 777,FOUT SECTION A-ASECTICDI A -ACC ST UCTIQ14PERMILBUFFER STRIP = GOJOINrrreueT.ou 3 creosswALK .' -. .. .. t ( �- SECTION B -B j CR05..whK W" TYPE A SECTION 8-B WITH BUFFER STRIP NOTES -F R 1 /I THE DETECTABLE WAR v SURFACE, SEE SHEET OF 5, IGN TOT D FOR GINNSTILST oM IH —I.PAp ELSWIDER FICIIAIFo LnNwnnc �IiieoEAr'rDP e RA... IruMJM cDft_ u� B re NE CLASS PJ CONCRETE SECTION A -A CLAPS P3 CONCRETE SECTION B -B `SC'AI F 1" = 25' NOTE'Cl GENERAL NOTES ON rHE DETECTABLE WARNING SURFACE. CROESWALI` ,�5 osswaw anew Ah ,.EST OF 5. '��/ coNs°raEcn°aN, r, FA' FCR ALTERAncN NOTES: 1 THE STANDARD SAFETY SLAH (EL -1l IE TO BE USED ONLY WHEN SPECIFIED IN THE PLANS E DRANAGE SUMMARY SHEET PND/OR THE DRANAGE DESCRIPTION. FOR MANHOLES. JUNCTION BOXES, PND CROP INLETS WITH HEIGHTS GREATER THAN 12 FEET, THE SPACING OF THE REOu n'_D LEhGTH TYPICAL PLACEMENT sl; i 5 EET, RECA/DLCS.. OF i11C AT INTERSECTION PE. MI WITHIN CROSSWALK LE TYPE B PARALLEL 5 so wuK is APPLICATION <; e ;FCR sTR LENGi �eN 1 RADE M MLUM AMFGEi H DIAGONAL PLACEMENT 'S u E LAISTO SCGAR DI AARAA OWg51D5 °r OUTS E 5P`AL �nvRov ar°s LANDING �� P WITHIN - I IN 3 3 BEE MAFKE[G w N Q N CROSSWALK AtEA CFE "A'R" _CO RYA �U "� Q U ADJACENT SAFETY SLP185 SNPLL BE 8'TO 12'WITH NO SAFETY SLAB LOCATED WITHIN 6 FEET OF iN TOP OR BOT40M OF THE STRUCTURE. SAFETY SLABS SHALL NOT BE LOCATED BELOW T LET PIPE OF 30"' DIAMETER OR GREATER. 2. THE COST OF THE EL -T IS INCLUDED IN THE COST OF THE STRUCTURE. J. S PENINGS ME TO BE STAGGERED FROM ONE SIDE OF STRUCTURE TO THE OTHEN WHERE APPLICABLE. STEPS ME TO BE STAGGERED ACCORDINGLY. 4. SAFETY SLAB MAY BE CISTHN-PLACE OR PRECAST. CASTHN-PLACE CONCRETE TO BE SEE CAST IN PLACE DRAWINGS FOR FURTHER DETNLS # 5 BARE v 6" C -C FOR, CONTOUR INTERVAL N/A P -1 E CDRO e�/may b �/ 3 GO ` CROSSWAf K -n- " 3000 PSD. PRECAST CONCRETE 15 TO BE A4 (4000 PSD. REINFORCING STEEL t0 BE IN ACCORDANCE WITH AASHTO M31. 5. EES OPENINGS MAY BE 30" DIAMETER OR 30" SOUME. WHEN STRUCTURE WIDTH Is ; —B - 1y °%'RED e z �, CROSSWALK C, H B L TYPICAL PLACEMENT , , d Cz �� LESS THAM 30" THE ACCESS OPENING SHALL BE RECTANGULAR (STRUCTURE WIDTH BY 3o'Cont). 'w V, _ LSEENGAREATYPICAL rz Rp AG 5 is L _ u� PLACEMENT AT INTERSECTION AT INTERSECTION CROSSWALK CROSSWALK WITHIN CROSSWALK DIAGONAL PLACEMENT TYPICAL PRECAST UNIT J 6 1 WITH BUFFER STRIP `'a"os:""xreE<. ossWAL" cE? ° `" R LITA WITHIN CROSSWALK', DIAGONAL PLACEMENT (WITH BUFFER STRIP) WITH BUFFER STRIP `V DDT SEE CATION ROAD AND BRIDGE 5TA1,11A s CG -12 DETECTABLE WARNING SURFACE'WA `REFERS"GE PECIFICATIO 'REFERENCE" CG -12 DETECTABLE WARNING SURFACE ROAD NDaDOT AI A DS E51+EET D2ROF VDOT SPECFC TO TYPICAL CONCRETE SAFETY SLAB FOR DROP INLETS( REFERENCEN ROM AND BRIDGE siaNOARos MANHOLES AND JUNCTION BOXES Lr '-" W w 'R stEEr . of s REVIswN PATE TYPE B (PARALLEL) APPLICATION IDs OFTRANSPORTATION 502 TYPE A (PERPENDICULAR) APPLICATION REVIswNAOAT."R10 5 X02 G 20306 SHEET 1 OF 1 REVISION DATE 302 108'14 VIRGINIA DEPARTMENT OF TRANSPORTATION Q I V (1) a. (j) N_ T >Z Oa:3 z N b 0y(z 0� 00<0 �mpC� 0 0 UMBER53 :78 Q+4'NI,TH Op P' 9 �U- �'r ! ✓/Jyl�yl immy L. Taggart Lio. No. 22841 44 �OF�93IONAL V'�al{� SHEET 8 Of 10 -'.\F TLIPr, D T¢'IL E,' 1. ]\PIT, _e _',. FILL I FI-I\BI-d ]-Ph- ' rn.TI FI T.dea �/°/SIT 1c [F AS P'J. A,an:.v I, F JUrICTI II i3QXES TP I`ISI 2M4 R PHD5, PEDESTALS, LIC- I..00ATION OF OTI'.k UTILITIES (GAS, ELECTRIC, TELF.P (?INE, CABLE, LIC.) EAS=fAENT WIDTH]: WATER OR ,E /EP. ONLY - '0' iAINIP'IIRA (NATER R SEWER 30 MININIUNi SEE PART 3, PARAGRAPH D; SEPA.RATIUN OF WATER d SEWER SYSTEMS. LfILITIE] CN )S SIN,� A WATER OR :`cWL-R EASEMENT SHOULD BE Al' 'a0" TCI THE RIGHT OF WAY, UTILITY LOCATIONS & EASEMENT WIDTHS ITA FIG. '✓A - I U-1 I' COMPRESS ON x 3/4' MALE PIPE COUPUNG ON _R.. EGDAL SOFT COPPER O o FORUSE ON AT ­s FAIIII BEGS SIR AL RESDENTnI ANN PRIGNININ SERVICS DU 1 xt"xt" IEE NO D (D NO SWEATED INTNOS z' DUAL SERVICE COMPRESSION x 3/4" MALE PIPE COUPLING CR APPR_C EGUAL SOFT COPPER O D FOR USE ON DETACHED SINGLE FAMILY ESOENTAL SERVICE WHERE AN RRGATON METER IS NOT PROVIDED. SINGLE SERVICE OTE' 1) SADDLES SHALL BE USED ON PVC PPE. F - CAST IRON LO SHED GRADE L.-NGME VAL.a'Iy ,E IALL sR o. I'NuiLE;1 = } - COPPERSETIER 1/5 BEND COUPLING-\ T ll -I E METER CORPORATION STOP NECe.AS ANY TYPICAL SERVICE LATERAL INSTALLATION (5/8" & 1" METERS) NTS FIG. W -6A TD -10 GOOD FOUNDATION MATERIAL ROCKY FOUNDATION MATERIAL e aenEllslcra r c INITIAL BALI<.FIL s s MIN N MIN^✓Ifl s n'J IO sl M1 J' #' S ;AIN! 1 11 A J. Ch AIEa TFIAIJ + PPC P_':ALS A 11 1 - SU13.NIH ED. 6" REDDING #68 STONE STABLE SI OIL ROC -IK * SCRAPE THE SCITTON1 OF THE TREFICH. REMOVE ALL STJI,F� PO INSURE THE PIPE DOESN'T REST ON ROCK AiJD THEN COMPACT THE SOIL OR PROVIDE A 4" BEDDING OF C63 STONE. FOUNDATION IN POOR SOIL UNDER - CUT CONDITION INITIAL EAC. h:FILL �! HISS L' &" j H . SOIL =_ 711 Nalw = rdlnl I i��hJl r _- 962 STONE 3 _AC GRAfdU LAR HILL AS ..Jf APPROVED BY A S4 :.. . 'TA Z,., STA6LE Snll. OR „OCA STAEI E SOIL OR ROC. F' NOTE 1. NO ROCKS SHALL BE ALLOWED WITHIN 24" OF THE WATERLINES. -.NO ROCKS LARGER THAN 6" IN ANY DIMENSION SHALL BE ALLOWED ABOVE THE INITIAL BACKFILL. 3.THE INITIAL BAO-KFILL SHALL BE PLACED AND COMPACTED IN 6" LIFTS. 4.GIO ORGANIC OR FROZEN MATERIAL OR DEBRIS SHALL BE ALLOWED IN THE TRENCH(. 5. BELL HOLES SHALL BE DUG OUT III ALL CASES. DUCTILE IRON WATER PIPE INSTALLATION & BEDDING IPS FIG, w - 2 TD -' COVER LIFT NOTCH 14 1/2+ - 12 1/2" - 12 3/8" WATER CAST IRON LID ' 18" METER BOX 18" 6" EXTENSION 6++ PIPE SLOT (2 PLACES) NOTES: (1) FOR TOUCH READ METERS A 1-3/4" DIAMETER HOLE IS REQUIRED IN THE LID. TYPICAL METER BOXES METERS) NTS FIG- W-7 TD -10 45 L \` 'd5 rte.;.•./.,_ f/`�✓.j 1145" PLUG l B. IIS FOR ALL BENDS FOR TEE OR WYE FITTINGS WHEN TRENCH �.T\�/A ANCHOP,ACCCMIIiD.4TE \Y/�l/:%/l%�. _ 2F+ HEL ,UIREU. c Ir M EEGDII'IG AS } RFOUIRED K® ; "�! PLUG I� AS MTJ a / SECTION 1 -1 SECTION 2 - 2 n PIPE _L�kLE 6E1'ID Dllrt-f'-IJNS VJL. TEE AfJIJ I`:.UGS VOL. SI_E OF _ (FEET) CU 1'G.: (FE ETI CU.Y'D R ErIU __- __- ____- L H T L H T - - -- 2.sn z sov� 3.01 o.za - 45 2 00 .2_ ,.SO a.15 •• /_' LL 200' 2.52 0.10 2.00 __ 2.50 CIA -- -- 11 1/4 1.50 1 -f.,01 3.E0 U.10 0 TtiP 3.10 _.21 0.4& .I 2.66 .66 J./7 0. `„ I _ 3.10 z ,'i /2 I > r,L � 2.6' 0.32 ' ~� 1.56 2.16 ._J 0.13 ITL i/4 1.66 2.10 0.73 0 7.6' 90 .s3 3.83 3.42 0 8 I 3.33 3. 1.95 ID ' 1� j 3. I I F;S x.00 I /? 2.33 2.86 0. I I �a 1.63 2.33 2.°.i 0 is .L_... 1. THRUST CUJC.KS ARE REI,UIRED GHEHEVER HE PIPELINE CHANCES DIRECTION, CHAR SIZE, DPAG' EINES AND AT VALVES. USE '_SOU f.s.l. EL, JC RETE. 3. Ho C0'JC R ETE SHALL BE POURED ON A.N'f PARI OF THE JOINT. -1. THE GO'r+ISUL 11 NG ENGINEER SHALL BE P.ESPOI`ISI6LE TO IHE V,-:RIFY THE TYPE 3 SIZE ALI- THRUST BLOCKS. CONCRETE THRUST BLOCKS NITS FIG. N.y-3 A I SIDE VIEW ( I TYPICAL METER VAULT N. E.S. FIT. N. - 7A TD -11 1.75" DIANE rE.1 DP�IUED HOLE fl)Il IlUCH READ U N. rs. TOP VIEW . IAME.TFR FLAr 6E.ARIr.G SURFV-E UND-PNEATH o" ALLI,MINUM ACCLSS HAI -H RIVANNA WATER & SEWER AUTHORITY (RWSA GENERAL WATER & SANITARY SEWER NOTES LAST REVISED: APRIL 2016 1.ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL COMPLY WITH THE LATEST VERSION OF THE GENERAL WATER AND SEWER DESIGN AND CONSTRUCTION STANDARDS - VERSION 1.0, ADOPTED IN DECEMBER 2015, EXCEPT AS MODIFIED BELOW OR MODIFIED IN SPECIAL NOTES. 2.RWSA SHALL APPROVE ALL CONSTRUCTION MATERIALS AND METHODS OF CONSTRUCTION. A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH RWSA PRIOR TO THE START OF ANY WORK. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 4.RWSA ENGINEER (VICTORIA FORT AT (434) 977-2970 EXT. 205) SHALL BE NOTIFIED THREE BUSINESS DAYS PRIOR TO THE START OF CONSTRUCTION. 5.ALL WORK IS SUBJECT TO INSPECTION BY RWSA STAFF. NO TIE-INS TO THE EXISTING SYSTEM SHALL BE MADE WITHOUT COORDINATION WITH AND THE PRESENCE OF RWSA STAFF. NO WORK SHALL BE CONDUCTED ON RWSA FACILITIES ON WEEKENDS OR HOLIDAYS WITHOUT SPECIAL WRITTEN PERMISSION FROM RWSA. 5.FOR SANITARY SEWER LINE CONSTRUCTION: RWSA MAY REQUIRE Q E BYPASS PUMPING FOR TIE-INS TO THE EXISTING SYSTEM. ALL DOGHOUSE MANHOLES MUST BE PRESSURE -TESTED BEFORE A CONNECTION IS MADE TO THE SYSTEM. 7.THE LOCATION OF EXISTING UTILITIES AS SHOWN ON THE PLANS IS FROM DATA AVAILABLE AT THE TIME OF DESIGN AND IS NOT NECESSARILY COMPLETE OR ACCURATE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION OF THE LOCATION, SIZE AND DEPTH OF ALL EXISTING UTILITIES, BOTH SURFACE AND SUBSURFACE. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN THE PLANS AND FIELD CONDITIONS. THE CONTRACTOR SHALL USE DUE DILIGENCE TO PROTECT ALL UTILITIES AND STRUCTURES FROM DAMAGE AT ALL TIMES, WHETHER SHOWN ON THE PLANS OR NOT. DAMAGE TO ANY EXISTING UTILITIES SHALL BE REPAIRED BY THE CONTRACTOR TO THE ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER. 8.EROSION AND SEDIMENT CONTROL FACILITIES SHALL NOT BE PERMITTED IN THE RWSA EASEMENT WITHOUT SPECIAL WRITTEN PERMISSION FROM RWSA. NO GRADING SHALL BE PERMITTED IN THE RWSA EASEMENT UNLESS PERMITTED OTHERWISE BY RWSA IN WRITING. 9.NO BLASTING SHALL BE PERMITTED WITHIN 100 FEET OF RWSA FACILITIES WITHOUT WRITTEN PERMISSION AND RWSA APPROVAL OF THE BLASTING PLAN. GROUND MONITORING DURING BLASTING AND A PRE -BLAST SURVEY MAY BE REQUIRED. FOR BLASTING WITHIN 100 FEET OF ANY OPERATIVE RWSA SEWERLINES, BYPASS PUMPING AND/OR PRE- AND POST -CCN MAY BE REQUIRED. RWSA MAY ALSO REQUIRE CERTIFICATION FROM A LICENSED PROFESSIONAL ENGINEER STATING THAT THE PROPOSED BLASTING WILL NOT DAMAGE ANY RWSA FACILITIES. DAMAGE TO ANY UTILITIES DUE TO BLASTING SHALL BE REPAIRED BY THE CONTRACTOR TO THE ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER. 10. THE CONTRACTOR SHALL OBSERVE MINIMUM SEPARATION REQUIREMENTS FOR UTILITY CROSSINGS. WHEN A CROSSING IS MADE UNDER AN EXISTING FACILITY ADEQUATE STRUCTURAL SUPPORT SHALL BE PROVIDED FOR THE EXISTING PIPE. THE AREA OF THE CROSSING SHALL BE BACKFILLED WITH COMPACTED 57 STONE TO THE SPRINGLINE OF THE EXISTING PIPE. 11. NEW WATER MAIN INSTALLATIONS SHALL BE PRESSURE TESTED, CHLORINATED, FLUSHED AND HAVE WATER SAMPLES APPROVED PRIOR TO MAKING ANY PERMANENT CONNECTION TO THE PUBLIC WATER SYSTEM. APPROVED METHODS OF FILLING AND FLUSHING NEWW WATER MAINS WILL BE REQUIRED TO PREVENT ANY CONTAMINATION OF THE PUBLIC WATER SYSTEM. 12. ALL EASEMENTS FOR NEW RWSA FACILITIES SHALL BE RECORDED PRIOR TO PLACING THE NEW FACILITIES INTO SERVICE. 13. NO PERMANENT STRUCTURAL FACILITIES WILL BE PERMITTED IN THE RWSA EASEMENT. THIS INCLUDES BUILDING OVERHANGS, RETAINING WALLS, FOOTERS FOR ANY STRUCTURE, DRAINAGE STRUCTURES, ETC. 14.TREES ARE NOT PERMITTED IN THE RWSA EASEMENT. y 44" MIN. _ i _ 6" MIN. 17.5 fa •60, -I '� 36" ►I 1d' MIN. t-17.5"- 37' MIN. WINGNUT LOCKING ASSEMBLY W. MIN. BYPASS NOTES: 1. PROVIDEf A 6 THICK GRAVEL BED BENEATH THE METER VAULT. 2. MINIMUM WALL THICKNESS FOR PRECAST OR POUR -IN-PLACE VAULTS SHALL BE 4". MINIMUM WALL THICKNESS FOR VAULTS CONSTRUCTED OF MASONARY BLOCK SHALL BE 8++. 3. THE OUTSIDE OF THE VAULT BELOW GRADE SHALL BE COATED WITH AN APPROVED WATER PROOFING COMPOUND. TYPICAL METER VAULT (1 1/2" METERj NTS FIG. W -7B ID -15 ��KyTH Op `rbc �'mmy L. Taggart UG. NO. 22841 v4 �a�Essl ONAL E�C'1�4 A V * Z U 2 N� Q 7 J 2 (D Q. O QQ2 CW 50 ° N yy Q °¢ F , '''d co �j 2 o °CCLU Upc�dv N Ol ¢O V ft IO ¢ . J LL? OLL 22 9coN 4W t9 rMM� N u- a�§ Z ILO % REVISIONS 03/28/2018 COUNTY COMMENTS 05/0712018 COUNTYCOMMENTS DATE JAN. 12, 2018 SCALE 1°=2s' CONTOUR INTERVAL N/A FILE NUMBER 8053 =SHEET Harr --Pea Slzr. o-n',elas',Orl Do`,lalsorl aenEllslcra r c ' s n'J IO sl n,drl. #' S ;AIN! 1 11 A J. Ch AIEa TFIAIJ + PPC P_':ALS A 11 1 - SU13.NIH ED. A I SIDE VIEW ( I TYPICAL METER VAULT N. E.S. FIT. N. - 7A TD -11 1.75" DIANE rE.1 DP�IUED HOLE fl)Il IlUCH READ U N. rs. TOP VIEW . IAME.TFR FLAr 6E.ARIr.G SURFV-E UND-PNEATH o" ALLI,MINUM ACCLSS HAI -H RIVANNA WATER & SEWER AUTHORITY (RWSA GENERAL WATER & SANITARY SEWER NOTES LAST REVISED: APRIL 2016 1.ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL COMPLY WITH THE LATEST VERSION OF THE GENERAL WATER AND SEWER DESIGN AND CONSTRUCTION STANDARDS - VERSION 1.0, ADOPTED IN DECEMBER 2015, EXCEPT AS MODIFIED BELOW OR MODIFIED IN SPECIAL NOTES. 2.RWSA SHALL APPROVE ALL CONSTRUCTION MATERIALS AND METHODS OF CONSTRUCTION. A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH RWSA PRIOR TO THE START OF ANY WORK. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 4.RWSA ENGINEER (VICTORIA FORT AT (434) 977-2970 EXT. 205) SHALL BE NOTIFIED THREE BUSINESS DAYS PRIOR TO THE START OF CONSTRUCTION. 5.ALL WORK IS SUBJECT TO INSPECTION BY RWSA STAFF. NO TIE-INS TO THE EXISTING SYSTEM SHALL BE MADE WITHOUT COORDINATION WITH AND THE PRESENCE OF RWSA STAFF. NO WORK SHALL BE CONDUCTED ON RWSA FACILITIES ON WEEKENDS OR HOLIDAYS WITHOUT SPECIAL WRITTEN PERMISSION FROM RWSA. 5.FOR SANITARY SEWER LINE CONSTRUCTION: RWSA MAY REQUIRE Q E BYPASS PUMPING FOR TIE-INS TO THE EXISTING SYSTEM. ALL DOGHOUSE MANHOLES MUST BE PRESSURE -TESTED BEFORE A CONNECTION IS MADE TO THE SYSTEM. 7.THE LOCATION OF EXISTING UTILITIES AS SHOWN ON THE PLANS IS FROM DATA AVAILABLE AT THE TIME OF DESIGN AND IS NOT NECESSARILY COMPLETE OR ACCURATE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION OF THE LOCATION, SIZE AND DEPTH OF ALL EXISTING UTILITIES, BOTH SURFACE AND SUBSURFACE. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN THE PLANS AND FIELD CONDITIONS. THE CONTRACTOR SHALL USE DUE DILIGENCE TO PROTECT ALL UTILITIES AND STRUCTURES FROM DAMAGE AT ALL TIMES, WHETHER SHOWN ON THE PLANS OR NOT. DAMAGE TO ANY EXISTING UTILITIES SHALL BE REPAIRED BY THE CONTRACTOR TO THE ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER. 8.EROSION AND SEDIMENT CONTROL FACILITIES SHALL NOT BE PERMITTED IN THE RWSA EASEMENT WITHOUT SPECIAL WRITTEN PERMISSION FROM RWSA. NO GRADING SHALL BE PERMITTED IN THE RWSA EASEMENT UNLESS PERMITTED OTHERWISE BY RWSA IN WRITING. 9.NO BLASTING SHALL BE PERMITTED WITHIN 100 FEET OF RWSA FACILITIES WITHOUT WRITTEN PERMISSION AND RWSA APPROVAL OF THE BLASTING PLAN. GROUND MONITORING DURING BLASTING AND A PRE -BLAST SURVEY MAY BE REQUIRED. FOR BLASTING WITHIN 100 FEET OF ANY OPERATIVE RWSA SEWERLINES, BYPASS PUMPING AND/OR PRE- AND POST -CCN MAY BE REQUIRED. RWSA MAY ALSO REQUIRE CERTIFICATION FROM A LICENSED PROFESSIONAL ENGINEER STATING THAT THE PROPOSED BLASTING WILL NOT DAMAGE ANY RWSA FACILITIES. DAMAGE TO ANY UTILITIES DUE TO BLASTING SHALL BE REPAIRED BY THE CONTRACTOR TO THE ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER. 10. THE CONTRACTOR SHALL OBSERVE MINIMUM SEPARATION REQUIREMENTS FOR UTILITY CROSSINGS. WHEN A CROSSING IS MADE UNDER AN EXISTING FACILITY ADEQUATE STRUCTURAL SUPPORT SHALL BE PROVIDED FOR THE EXISTING PIPE. THE AREA OF THE CROSSING SHALL BE BACKFILLED WITH COMPACTED 57 STONE TO THE SPRINGLINE OF THE EXISTING PIPE. 11. NEW WATER MAIN INSTALLATIONS SHALL BE PRESSURE TESTED, CHLORINATED, FLUSHED AND HAVE WATER SAMPLES APPROVED PRIOR TO MAKING ANY PERMANENT CONNECTION TO THE PUBLIC WATER SYSTEM. APPROVED METHODS OF FILLING AND FLUSHING NEWW WATER MAINS WILL BE REQUIRED TO PREVENT ANY CONTAMINATION OF THE PUBLIC WATER SYSTEM. 12. ALL EASEMENTS FOR NEW RWSA FACILITIES SHALL BE RECORDED PRIOR TO PLACING THE NEW FACILITIES INTO SERVICE. 13. NO PERMANENT STRUCTURAL FACILITIES WILL BE PERMITTED IN THE RWSA EASEMENT. THIS INCLUDES BUILDING OVERHANGS, RETAINING WALLS, FOOTERS FOR ANY STRUCTURE, DRAINAGE STRUCTURES, ETC. 14.TREES ARE NOT PERMITTED IN THE RWSA EASEMENT. y 44" MIN. _ i _ 6" MIN. 17.5 fa •60, -I '� 36" ►I 1d' MIN. t-17.5"- 37' MIN. WINGNUT LOCKING ASSEMBLY W. MIN. BYPASS NOTES: 1. PROVIDEf A 6 THICK GRAVEL BED BENEATH THE METER VAULT. 2. MINIMUM WALL THICKNESS FOR PRECAST OR POUR -IN-PLACE VAULTS SHALL BE 4". MINIMUM WALL THICKNESS FOR VAULTS CONSTRUCTED OF MASONARY BLOCK SHALL BE 8++. 3. THE OUTSIDE OF THE VAULT BELOW GRADE SHALL BE COATED WITH AN APPROVED WATER PROOFING COMPOUND. TYPICAL METER VAULT (1 1/2" METERj NTS FIG. W -7B ID -15 ��KyTH Op `rbc �'mmy L. Taggart UG. NO. 22841 v4 �a�Essl ONAL E�C'1�4 A V * Z U 2 N� Q 7 J 2 (D Q. O QQ2 CW 50 ° N yy Q °¢ F , '''d co �j 2 o °CCLU Upc�dv N Ol ¢O V ft IO ¢ . J LL? OLL 22 9coN 4W t9 rMM� N u- a�§ Z ILO % REVISIONS 03/28/2018 COUNTY COMMENTS 05/0712018 COUNTYCOMMENTS DATE JAN. 12, 2018 SCALE 1°=2s' CONTOUR INTERVAL N/A FILE NUMBER 8053 =SHEET 0.'.F TI;IFFIi I`,rU53 lLG TF, IL 6LIlF'/ 7 F'h.. .. 2'`. N,n I PI - ,AI.I Phu_. _ I-1— 1—, 5;'_'/^013 ':3';: �7 M. A-,e°- irs o E oy WJ w m om a � wa IF Na rnI`;OT N v Q w oM t� EroM O E Ea �, n O O \� \E n E Ly o F o i� a_ E ¢Y o f a E Z o E� O �,o o� ��ow .. y Lj E u E �Evii LO ` //� ✓I ��REMAINING BACKFILL SHALL CONFAIPI ROri, MATERIAL f/ LARGER THAN 5' ANY 3L MIr IN DIMEN ION >l Mlft INTIA BACIPFIII.` b"Mlf'1 5" LIFTS) EMBEDMEi`1T ; Ti1OROUGHLY IMPACTED —Ijg /�\ B`! HAND OR APPROVEDu (L MECHANICAL —1 /\ MECHANICAL TAMPER NO. 68 STCIGIE ��-_ HAUNC HIPJG — BEDDING 6" mar 4" min FOUPIDATION (SHALL BE REQUIRED WHEN SOIL ^�%J/N/;: �`/q CVNDITIOfJS ARE UNSTABLE //�/�S (ALL PIPE) S/l�lG/���%� NOTE LU Efl CUFS IN PAVED AREAS WIFI TIN EXISTING VDOT EIGHT--OF-WA'r' SI -TALL QE WITH NO. 41A STONE BAC KI=IDLED EROLI � SEWER SERVICE LATERAL CONNcCIION NOTES: I WHERE A SEWER ERVI-E LAl FAL BONNE 1S T A JANHC',LE \IJD NO INVERT ELEVATION FOR THE SERVICE LATEPAI IS IIIEICATED THE FOP (CPOWN) LEV TI'JJ. OF THE SERVICE LA FEI Al -PIPE SHALL CE AT LEAST 0 HI HEIS THAN THE IJP Il R\WN) ELEVATI-'rd fF FHL -HE LJbJE-T PIPE OVfJE 'I"ED ) THF MANIC LE 2. SEWER FAiERALS TAPPED INTO AD EXISHN -Eb!ER MAIN -HALL �E OfJ fJE -i-D US" J A FIFE SADDLE 3. "1NJl'P GRACE FOR SEWER oLk\._E Cor.NESTION SHALL Gh -"; ,�, (t/•i' PER FOOT) :t. ALL SE`/✓Ea LATERALS SHALL H°.VF. 1 MINIMUM -OVER DIAMETER NIfJ of a 5. ALLF�[v„FRET?,TEHAI-S SHALL HAVE A MINIM4UM r�IVER SALT --/W TREATED FINISHED GROUND 2 , 4 MARKER LUQ END OF SERVICE LATERAL .1AIfJ LINE SECTION I U a W O Z �! 2 NCD, e g= l 2 c�QQm NNJ411 O S N O Q ¢W 50 a2 2 O N ILL! JZ 0� rT} U r� N Opp Vcc NUI Q X v LL2 �LL¢ �l O Y dN 0Lua Z r`n �' 2 C ® Z 0 0 _E o ¢ ¢ aE Q m \� \^ o E E N m _ N r PI 4 SHALL G SCRAPED G.AN DUC FILE ED, PIPE THE ONES M THE OR AND COMPACTED, AND AEI- STONES REMOVED OR A 4" BEDDING OF NO. e8 STORE SHALI- BE PROVIDED 3.WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM n BEDDIfJG UF- IVO. 6E STONE TYPICAL SEWER PIPE />// =,�f '45 U'O' ! [y _ _ Ll DIJE WYE -TEE �i ��� PLAN O W REVISIONS 03/28/2018 COUNTY COMMENTS 05/02/2 COUNTY 2/2 18 TB INSTALLATION IN TRENCH VS nRIE- TYPICAL MANHOLE FRAME & COVER NTS S-3 SEWER SERVICE LATERAL CONNECTIONFIG. N.T.S FIG S -I -D TD -28 IN T,S Flr�. S-2 TD -25 TD -27 DATE SANITARY SEWER NOTES JAN. 12, 2018 scALE RIVANNA WATER & SEWER AUTHORITY (RWSA) 1. ALL CONNECTIONS TO RWSA MANHOLES SHALL BE WATERTIGHT AND MADE WITH A FLEXIBLE RUBBERBOOT. 2. ALL CORING METHODS, THE CORING CONTRACTOR AND ALL MATERIALS FOR CONSTRUCTION SHALL BE APPROVED BY RWSA IN WHITING PRIOR TO CONSTRUCTION. 3. RWSA ENGINEERING STAFF SHALL BE PRESENT FOR ALL CORES INTO THE MANHOLES. CONTACT RWSA ENGINEERING A MINIMUM OF 3 BUSINESS DAYS IN ADVANCE TO SCHEDULE A CORE OF A MANHOLE. 4. BYPASS PUMPING MAY BE REQUIRED AT THE SOLE DISCRETIONOF RWSA STAFF. 5. GROUTING OF THE MANHOLE BENCH OR INTERIOR MAY BE REQUIRED, AT THE SOLE DISCRETION OF RWSA STAFF, FOR A SMOOTH TRANSITION OF FLOW. 6. EXISTING MANHOLES SHALL BE BACKFILLED TO ORIGINAL GRADE TO THE SATISFACTION OF RWSA. CONTOUR INTERVAL NSA MATERU,S TO TRENCH SPOILS TO BE PfACED ON THEGROUND TO BE GRADED NIGH ACEDOFNTRENCH /LOW SIDE OF TRENCH MIR CONTOURS DURING CONSTRUCTION. / DURING CONSTRUCTION. AFTER BACKFlLL • •• •• •• •• •••• •• •• • / TOP OF GROUN .: :� � � ::^:: OQw - --- W N Z lW Q V ( 1 1 rLnY /� � V / LL � Z uj =�J 3 COMPACTION PER COUNTY SPECIFlCAPON (REMNNING BACKBLL SHALL NOT COWAN ROCK, CLOD, OR DEDRIS MATERIAL IARCER THAN 5• IN ANY DIMENSION. 24• MIN. .: ;.8;' .'..MIN. THOR BACKFlLL" (fi• LIFTS) ' COMPACTED BY -1W OR APPROVED OR PPPRONLY MECHANICAL TAMPER. EMBEDMEM 'ONLY DIAMETER OF PIPE —SPRING UNE OF PIPE .._ HUNCHING MAX. BEDDING: 6: MIN. 4 NO. 68 STONE .. ... ... ... :.'.' '� FOUNDATION (SHALL BE REQUIRED WHEN SOILDO CONDITIONS PRE UNSTABLE) [ALL PIPE] NOTE: CONTRACTOR MUST INSURE THE STONE IS PROPERLY COMPACTED, ESPECIALLY UNDER THE HAUNCHES OF THE PIPE. BEDDING, BACKFILL AND TRENCH SPOIL PLACEMENT W (L LZ 1 L 0 U J 06 c + W O Q co 0 /Y OI W LL N U Q of t, FILE NUMBER 77 A/° > m(ny L. T,dggart Lic. No. 8053 22841 �of�ssl ONAL F'�Gt}w SHEET 10 Of 10 0.'.F TI;IFFIi I`,rU53 lLG TF, IL 6LIlF'/ 7 F'h.. .. 2'`. N,n I PI - ,AI.I Phu_. _ I-1— 1—, 5;'_'/^013 ':3';: �7 M. A-,e°-