Loading...
HomeMy WebLinkAboutSDP201800054 Approval - County 2018-09-06COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 September 6, 2018 Scott Collins, P.E. Collins Engineering 200 Garrett Street, Suite K Charlottesville, VA 22902 RE: SDP201800054 and SUB201800119 Brookhill Block 8B — Initial Site Plan and Preliminary Subdivision Plat - Action Letter Mr. Collins: The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced site plan and plat. See below and attached for conditions and process: SITE PLAN: This approval shall be valid for a period of five (5) years from the date of this letter, provided that the developer submits a final site plan for all or a portion of the site within one (1) year after the date of this letter as provided in section 32.4.3.1 of Chapter 18 of the Code of the County of Albemarle, and thereafter diligently pursues approval of the final site plan. In accordance with Chapter 18 Section 32.4.2.8 Early or Mass Grading may be permitted after the following approvals are received: 1. Engineering approval of a VSMP plan meeting the requirements of Chapter 17 of the Code of the County of Albemarle. 2. Approval of all easements for facilities for stormwater management and drainage control. 3. Submittal of a tree conservation checklist with areas for tree preservation identified. The final site plan will not be considered to have been officially submitted until the following items are received: 1. A final site plan that satisfies all of the requirements of section 32.6 of Chapter 18 of the Code. 2. Applicable fee outlined in the application. SUBDIVISION: This approval shall be valid for a period of five (5) years from the date of this letter, provided that the developer submits a final plat for all or a portion of the site within one (1) year after the date of this letter as provided in the Section 14-226 of the Code of the County of Albemarle, and thereafter diligently pursues approval of the final plat. The final plat will not be considered to have been officially submitted until the following items are received: 1. A final plat that satisfies all of the requirements of section 14-303 and sections 14-304 through 14-318 of the Code, and the conditions attached to this letter. 2. Applicable fee outlined in the application. Please submit 8 copies of the final plans to the Community Development Department for both the site plan and subdivision plat. The assigned Lead Reviewer will then distribute the plans to all reviewing agencies. The Department of Community Development shall not accept submittal of the final site plan or subdivision plat for signature until tentative approvals for the attached conditions from the following agencies/reviewers have been obtained: SRC Members. Albemarle County Planning Services (Planner) — 2 copies (Cameron Langille, blan ig_llegalbemarle.org) Albemarle County Engineering Services (Engineer) — 1 copy (Emily Cox, ecox(aalbemarle.org) Albemarle County Information Services (E911) — 1 copy (Elise Kiewra, ekiewra(aalbemarle.org) Albemarle County Building Inspections — 1 copy (Michael Dellinger, mdellinger(kalbemarle.org) Albemarle County Planning Service (Architectural Review Board) — 1 copy (Heather McMahon, hmcmahon(a) albemarle.org) Albemarle County Fire & Rescue — 1 copy (Shawn Maddox, smaddox(calbemarle.org) Albemarle County Service Authority — 1 copy (Richard Nelson, rnelson(a),serviceauthority.org) Rivanna Water and Sewer Authority — 1 copy (Victoria Fort, vfortgrivanna.org) Virginia Department of Transportation — 1 copy (Adam Moore, adam.moore(&vdot.virginia.gov) If you have any questions about these conditions or the submittal requirements please contact me at extension (434) 296-5832 ext. 3432 or blan ig'lle(&albemarle.org. Sincerely, Cameron Langille Senior Planner CC: Alan Taylor Riverbend Development 321 E. Main Street Charlottesville, VA 22902 alan@riverbenddev.com Albemarle County Planning Services (Planner) — Cameron Langille, blan ig lle(c-r�,albemarle.org — Required changes: Changes to be addressed prior to final site plan and final plat approval: [32.5.2 (i)] Please address the following comments related to road improvements: a. The final site plan for Block 8B will need to accurately depict all improvements within the right-of- ways visible on the plans. A road plan application must be submitted, reviewed, and approved prior to final site plan and final plat approval. Once the road plans are approved, the right of ways for new streets in Block 8B must be reviewed, approved, and recorded prior to final site plan approval. b. [14-410 and 14-4221 Alley A must have sidewalks and street trees along both sides of the street. c. All roads shown within Block 8B are labeled as proposed private streets or private alleys. Per Section 2.8.1 on pages 24-25 of the Code of Development, the following streets within Block 8B are required to follow the "Neighborhood Streets — VDOT Public Roads" standard: all of Wesley Circle, Noush Lane, and Road E. The streets shown do not have the required features for the Neighborhood Streets type, including parking along one side of the street. Please revise. If the layout and design of Block 8B is affected due to widening the right of way to incorporate on -street parking, the site plan and preliminary plat may need to go through the site review committee again. d. Please label all roads visible on Block 8B final subdivision plat with a width measurement and state whether the road is public or private. Prior to final plat approval, all street right of ways that have been dedicated to public use or under private easement should feature a label stating the deed book and page number. 2. [General Comment] Lots 16-27 do not meet minimum frontage requirements because their driveway is shown along Alley A/Noush Court and the other side of the lot fronts along a private street "Road E." See page 30 of the Code of Development for further information. a. Per discussion between staff and the applicant at the Site Review Committee Meeting, the plans will be revised so that Road E is designed to the "Neighborhood Streets — VDOT Public Roads standard in Section 2.8.1 of the COD. 3. [ZMA201500007] Sheet 2 is not the approved Application Plan. Revise to include the approved plan that was modified at the Board of Supervisors meeting to not include the trailhead at Ashwood Blvd. Link to approved plan. 4. [Application Plan; COD; Proffers] When will the greenway easement within Block 8A be dedicated to public use? Per proffer #2 of ZMA201500007, the greenway must be dedicated to the County. 2,4 _Greenspace and Amenities 13rookhilI will feature ower 100 acres ofGreenspace This Greenspace represents more than 35% of the entire community's land area, and includes the Buffer areas, the Greenway and stream buffers, parks and civic amenity areas, and general open space The Greenspace will not only provide a linear trail system throughout the community, but shall also preserve environmentally sensitive areas such as steep slopes, streams, and stream buffers All of the Greenspace areas shall be located outside of private lots and right -of --way All Greenspace within Brookhill, with the exception of the Greenwway, will be owned and maintained by the Homeowners Association. Establishment of the buffers, trails, and amenities within the Greenspace will be the responsibility of the developer UP011 written request by [lie County, but nor prior to the issuance of [hc five hundredtli (5000)) Pcrtnit for a klwclling within the Pro. ect. the thwnzr shall dLAicaic to 1 c County an onwi 7enr for public use over the Greenwsy area, si; shown on the Application flan. Prior to the C'ounly's request to dedicate such casement, the Owner inay dedicate portions of the Greenway by casein nt concurrently with one or more subs iti ision plats for anaas ling adjacent to the Gjnr onway: prDvlded however, that Owner way re;,erue to quch cast cincnt,,. r ghm of access for grading, ulilitics and waint.QnanC,�. each subdivision plat shall depicl the Greenway area ro be dedicared and shall bear a notation that the Grecnway area is dedicated for pubhC use• IF, itt [he time the County ruluems dcdif amion cif [he Circenway. any pirt of the Grecnway that has not heed dedicalt d by subdivision p1m.. shall be (within six (6) nwnth-, of sxich reitucsi) al Owner's cost, suncyed. }Matted and recorded with one or rnDrc deeds of cascnscrit dedication. 5. [ZMA201500007] hi accordance with Section 2.14 on page 31 of the COD, lots 31-35 do not qualify as amenity oriented lots because there is not an open area that is 50' in width from face of building to face of building. These lots must be served by a public street. See comment #2 above for further information. 6. [32.5.2 (o) and ZMA201500007] Please expand the Block Area Summary on Sheet 3 to include all the columns contained in Table 2 of the Code of Development. The required and proposed acreages of each feature should also be stated so that staff can verify compliance with the minimum requirements for greenspace/amenities, as well as the development area requirements. a. The proposed acreages of each feature in Blocks 3 and 4 that are currently under site plan review should also be stated even though they are not part of the Block 8B initial site plan/preliminary plat review. b. The Block Area Summary on Sheet 3 does not include the proposed acreage of Block 4C, please revise. c. Under "Land Areas" on Sheet 1, please state the acreage of land within the "development area" as shown in Table 2 on page 6 of the Code of Development. d. The "Land Areas" note should also contain the proposed acreage of amenity areas. 7. [32.5.2 (a)] The land area of all blocks in Brookhill may not be modified more than 15% of the gross land area shown in Table 2 (page 6) of the Code of Development. Please be aware that the proposed gross land area (20.7 acres) of Block 8A and 8B is currently modified by 20% (5.1 acres less than the acreage specific in the COD), according to the Total Project Area on Sheet 1. This is not permitted. a. The "Land Areas" and "Open Space Provided" sections on Sheet 1 do not match the "Total Project Area" on Sheet 1, or the Block Area Summary on Sheet 3, or the Open Space Calculation on Sheet 5. Please revise and comply with the requirements of Table 2 of the Code of Development. 8. [32.5.2 (a)] Please amend the watershed note on Sheet 1 to state whether that is a water supply watershed. 9. [32.5.2 (a)] Prior to final site plan approval and plat approval, please revise the Existing Conditions and all other applicable drawings where adjacent properties are visible. The correct so that the correct Tax Map Parcel numbers for the Block 3A Ice Rink and Block 4 apartments may exist by the time of final review and these should be labeled with the correct deed book and instrument number. 10. 132.5.2 (a)] On Sheet 1, please state the Special Use Permit application number that was approved to allow grading activities in the Flood Hazard Overlay District. The approved application number is SP201500025 and the County approval date was November 9, 2016. a. Please add the approved conditions of SP201500025 to the final site plan and plat. 11. [32.5.2 (a)] Under Zoning on Sheet 1, please state the Board of Supervisors approval date of November 9, 2016 to the notes for both SP201500025 and ZMA201500007. 12. [32.5.2 (a)] Please amend the Zoning note on Sheet 1 to include all applicable overlay districts. It should state Neighborhood Model Development District as the primary zoning district. Block 8B also lies within the following overlay districts: EC - Entrance Corridor Overlay, AIA — Airport Impact Overlay, and Managed and Preserved Steep Slopes Overlay Zoning Districts. 13. [32.5.2 (c)] The limits of managed and Preserved Steep Slopes are not shown on the drawings as stated in the Note on Sheet 1. Please show the limits of these features. a. Please be aware that all Preserved Steep Slopes areas must be located within open space and need to be shown on the final site plan and plat. 14. [32.5.2 (a)] Please add a note to Sheet 1 titled "Block Classification" with "Neighborhood Density Residential" as the block type for Block 8B, as stipulated by the Brookhill Code of Development. 15. [32.5.2 (b)] The Zoning Administrator and Director of Planning have determined that the proposed use in Block 8B is considered "Attached Single -Family Dwelling Units" as described in Sections 2.2.2 and 2.3.2.3 of the Code of Development and the County Zoning Ordinance. Please amend the "Proposed Use" on Sheet 1 to state "55 Attached Single -Family Residential Parcels — 110 Total Dwelling Units. See attached email. a. Please remove the use note on the drawings that states Block 8B is a multi -family condominium. 16. [32.5.2 (b)] Please state the maximum building footprint permitted on Sheet 1 in accordance with Table 2.3.2.3 on page 18 of the COD. 17. [32.5.2 (b)] Please state the minimum and maximum lot sizes permitted in Block 8B in accordance with Section 2.3.2.3 on page 18 of the Code of Development. 18. [32.5.2 (a)] Please amend the setbacks note on Sheet 1. It should state all permitted setbacks (including porches and garages, as well as the notes column) in accordance with Table 2.3.2.3 from page 18 of the Brookhill Code of Development. a. The porches setback figure is incorrect, porches must be setback a minimum of 5' along the front property lines. b. Please revise the garage setback figures stated. The exhibit from page 30 of the Code of Development should be added as an inset to the setbacks note. The garage setbacks are different depending on the road scenario adjacent to a given lot. 19. [32.5.2 (a)] The minimum parking requirement calculation note on Sheet 1 is incorrect. Parking must be provided in accordance with Section 2.9 of the COD, and the garage and driveway exhibit shown on page 30 of the Code of Development. a. Each single-family lot must have a minimum of 2 off-street parking spaces. Since each lot will have two separate dwelling units, a minimum of 220 parking spaces total are required in Block 8B. There are currently on 36 on -street parking spaces provided, with a presumed 110 parking spaces (two each lot) on private lots. Please add the additional parking spaces as required. 20. [32.5.2 (b)] Please amend the "Allowable Density" note on Sheet 1. The allowable density for Block 8B is 2- 6 dwelling units/acre. 21. [32.5.2 (b)] Please provide a calculation of the proposed units per acre for Block 8B and overall Block 8. The "Proposed Density" note on sheet 1 does not state this. a. Please be aware that the du/acre proposed within Block 8B is approximately 15 du/acre as proposed. The Zoning Administrator has stated that the 110 dwelling units can be constructed in Block 8B as long as the future uses in Block 8A are not dwelling units. Essentially, the overall density throughout the entirety of Block 8 cannot exceed the 2-6 unit range. 22. [32.5.2 (a)] Per Table 2.3.2.3 of the Code of Development, please show the minimum and maximum setback lines locations across all applicable drawings. Label each setback line as a front, side, corner side, or rear setback and state the dimensions in the label. Setbacks should be measured from the proposed right-of-way. 23. [32.5.2 (n)] Pedestrian crosswalks must be provided at all locations within the site where ramps connect sidewalks on opposite sides of vehicular travel ways. a. Please label the dimensions and surface materials in compliance with the County's design standards. 24. [32.5.2 (n)] Please label and call out the locations of the primary and secondary building entrances to the building in accordance with the Neighborhood Density Residential block regulations Section 2.2.3 (page 11) of the Code of Development. a. Lots 16-27 and 31-35 do not currently meet the required building entrance locations since they do not front on a public street or amenity area. Final site plan and plat will not be approved until these lots front on a public street or an amenity area. 25. [ZMA201500007] No setbacks lines are shown on Lots 32-37, please revise. 26. [32.5.2 (a)] Block 8B must provide the minimum recreation area and facilities specified in Section 4.16 of the Zoning Ordinance. State the equipment for the playground area as well as what kind of sport court is being proposed. Show the materials and dimensions. 27. [32.5.2 (k)] Please show the location of all proposed sewer and drainage easements. Label as "proposed" with a size/width measurement. 28. [32.5.2 (1)] Please label all utility easements as "proposed" with a size/width measurement. 29. [32.5.2 (n)] Please state the proposed surface materials for all parking lots, travel ways, walkways, etc. in a label on the site plan drawings. 30. [COD; 32.5.2(a)] Some retaining wall heights exceed the 6' maximum requirement specified in the COD on pages 23-24. Please revise. 31. [32.5.2 (e)] Please provide more details about the existing landscape features as described in Section 18- 32.7.9.4(c). a. The Albemarle County Conservation Plan Checklist and Chapter 3.38 of the Virginia Erosion and Sediment Control handbook. The Conservation Plan Checklist will need to be signed by the owners and provided as an exhibit on the final site plan for Block 3A. 32. [32.7.9] The landscaping plan has none of the required information regarding the proposed landscaping, and is not clear. A detailed landscape plan in accordance with the ordinance is required for final site plan at a scale of 1"=30'. It appears that required landscaping is located within lots, if so, an easement on those lots will be required. Additional comments will be given at final site plan once a full landscape plan with more detail is submitted. 33. [32.7.9] Please provide individual landscaping schedules for required landscaping in accordance with Sections 32.7.9.5, 32.7.9.6, 32.7.9.7, 32.7.9.8 of the Zoning Ordinance. Each schedule should state the Botanical Name and Common Name of each species proposed, the proposed caliper and height at time of installation, and the canopy coverage canopy coverage area per plant species. The canopy area for each species can be found on the Albemarle County Recommended Plants List and Albemarle County Plants Canopy Calculations tables. PDFs of these documents can be accessed through the Department of Community Development webpage: LINK. 34. [32.7.9.5, and 14-410, and 14-4221 Street trees are not shown along Roads F, E, and Alley A. Please revise the landscaping plan. 35. [32.7.9.61 The 9 space parking lot at the south of Block 8B will need to be screened in accordance with Section 32.7.9.6 and 32.7.9.7 of the Zoning Ordinance. Staff cannot verify if the provided trees meet the minimum 5% canopy requirement. 36. [32.7.9.8 (a)] Please provide a calculation for the minimum tree canopy required and proposed in Block 8B based on the use type. The minimum tree canopy is 20% based on the density of Block 8B. a. [32.7.9.8 (b)] Please provide a landscape schedule that lists the Botanical Name and Common Name of each species is included, the proposed caliper and height at time of installation, and the canopy coverage area per plant species as stated on the Albemarle County Plants Canopy Calculations (this table should be specifically for the 20% minimum tree canopy requirement). 37. [32.7.9.91 Please add a note to the Landscape plans stating "All landscaping shall be installed by the first planting season following the issuance of the first certificate of occupancy within the development." 38. [32.7.9.91 Please add a note to the Landscape plans stating "All landscaping and screening shall be maintained in a healthy condition by the current owner or a property owners' association, and replaced when necessary. Replacement material shall comply with the approved landscape plan." 39. [32.6.2 (h)] Please provide a signature panel with a line for each member of the Site Review Committee. A copy of the SRC signature panel template is attached. 40. [ZMA201500007] Per Proffer #9A-C and Section 2.13 of the Code of Development, the historic marker to commemorate the Brookhill manor house shall be installed with the first phase of development. The marker is shown in different areas on the road plans for Block 3 and the Block 8B plans. Please clarify the location. 41. [ZMA201500007] Notes 1 and 4 on Sheet 1 conflict with what is shown on the plans. a. Drainage easements and required landscaping buffers (20' Polo Ground Road and the Block 19 buffer) must be within private easements to be owned and maintained by the Brookhill HOA. These will not be dedicated to public use, so Note 2 needs to be revised for clarity. b. Note 4 needs to be revised. If any landscaping required by the Zoning Ordinance will be within open space parcels, the HOA will maintain those features. All required street trees must be located within public or private road right of ways. 42. [14-317] An instrument evidencing maintenance of all required improvements that will not be owned or maintained by the County is required with the final. This includes private street and alley easements, sidewalk easements (if applicable), buffer easements, landscaping easements (if applicable), etc. 43. [General Comment] Please provide a narrative regarding the timeline for installation of the required 20' undisturbed and new landscaping buffer around the Brookhill manor house in Block 19 that is adjacent to Block 8B. Please see Section 2.4.2 of the Code of Development for the manor house buffer requirements. a. The Road 113 application (SUB201800115) proposes to disturb land and some existing trees on/adjacent to Block 19. Some drawings delineate an "Existing 20' buffer" near Block 19. The buffer needs to be located adjacent to but outside of the parcel boundaries of Block 19, per Section 2.4.2 and 2.13 of the COD. b. Pending applicant response to this comment, western and southern portions of the buffer may need to be shown on the Block 8B final site plan as required landscaping. The COD appears to allow the Block 19 buffer requirement to be satisfied in two general methods: i. Submit a subdivision plat to create the 3 +/- acre Block 19 parcel and include a buffer easement around the parcel on that plat. A landscaping typical section for the buffer will need to be provided as a plat detail specifying the types and quantities of vegetation to be planted in the buffer easement. ii. Install each side of the buffer as part of the subdivision plat, site plan, or road plan for adjacent blocks, including Block 8B. The landscaping plan for these applications will specify the types and quantities of vegetation to be planted in the buffer easement. 44. [4.17] Please provide a full lighting plan with the final site plan in compliance with Section 4.17 of the Zoning Ordinance. 45. [General Comment] The plans label a Day Breach Dam Break Inundation Zone. However, Albemarle County GIS shows no state dam break inundation zones within the development. Please clarify. 46. [General Comment] Please revise the Sheet List Table on Sheet 1 to match the sheet numbers provided. 47. [General Comment] Please see the attached document from the United States Postal Service regarding approval by the USPS for mail delivery locations. It is up to the applicant to coordinate a centralized mail delivery location for the lots in Block 8B in accordance with USPS requirements. Staff may ask for written verification from the USPS that a mail delivery location has been approved by the post master during review of the final plans. Please contact Cameron Langille at the Department of Community Development at blan ig llekalbemarle.org or 296- 5832 ext. 3432 for further information. Comments From Other Reviewers: Albemarle County Engineering Services (Engineer) — Emily Cox, ecoxgalbemarle.org— Requested Changes, see attached. Albemarle County Information Services (E911) — Elise Kiewra, ekiewrakalbemarle.or — Requested Changes, see attached. Albemarle County Building Inspections — Michael Dellinger, mdellingergalbemarle.org — Requested Changes: 1. Retaining walls greater than 3 feet in height require a separate building permit. Walls exceeding 4 feet in height require a stamped engineered design also. Albemarle County Planning Services (Architectural Review Board) — Heather McMahon, hmcmahon cr,albemarle.org — Requested Changes, see attached. Albemarle County Department of Fire Rescue — Shawn Maddox, smaddoxkalbemarle.org — Requested changes, see attached. Albemarle County Service Authority — Richard Nelson, rnelson&serviceauthority.org — No Objection, see attached recommendation. Virginia Department of Transportation — Adam Moore, Adam.Moore(&vdot.vir ig nia.gov — Requested changes, see attached. County of Albemarle Department of Community Development Memorandum To: Cameron Langille From: Emily Cox Date: 20 Aug 2018 Subject: Brookhill — Block 8B - ISP (SDP201800054) The initial site plan for Brookhill — Block 8B has been reviewed by Engineering. The following comments will need to be addressed before approval: 1. WPO Plan must be approved before final site plan can be approved. 2. Road Plan must be approved before final site plan can be approved. Road plan must include all roads encompassed by this site plan. There appears to be a road between sections 4A & 8A as well as through 8A. 3. VDOT approval is necessary before final site plan can be approved. 4. The minimum ROW (or easement width) is 30' per the Design Standards Manual. VDOT subdivision street design guide — Appendix b, section B-4-B-3-d states that the pavement width can be reduced to 22ft, but the right-of-way must still be 30 feet. 5. Ensure all critical slopes, buffers, etc. are shown as approved on ZMA 2015-007 on all applicable sheets. 6. Ensure the accurate FEMA 100 year floodplain is shown. The ZMA appeared to show the 500 year. Also, Note 4 states there is not floodplain, however there is floodplain shown on the plans. 7. Show how the proposed impacts to the steep slopes and Greenway compare to the approved ZMA. 8. On sheet 4, an approved VSMP plan is referenced. Provide the approved plan # and facilitiy ID's that are proposed to be modified or removed. 9. Show all proposed parking space dimensions (at each parking area). 10. Show top and bottom elevations of proposed retaining walls. Note that per COD, Page 23, the maximum height is six feet. 11. Please label contour elevations. 12. 2:1 Slopes should be avoided wherever possible. The 2:1 slopes behind lots 1-15 are not desirable. 13. Water quality and quantity requirements will be fully evaluated with the VSMP Plan submission. Please note that all concentrated outfalls must be analyzed to comply with state requirements. Also, water quality summary table for overall Brookhill Development must be provided. County of Albemarle Department of Community Development Memorandum To: Cameron Langille From: Emily Cox Date: 20 Aug 2018 Subject: Brookhill — Block 8B — Preliminary Plat (SUB201800119) The preliminary subdivision plat for Brookhill — Block 8B has been reviewed by Engineering. The following comments will need to be addressed before approval: 1. WPO Plan must be approved before subdivision can be approved. 2. Road Plan must be approved before subdivision can be approved. Road plan must include all roads encompassed by this site plan. 3. VDOT approval is necessary before subdivision can be approved. 4. Ensure all critical slopes, buffers, etc. are shown as approved on ZMA 2015-007 on all applicable sheets. 5. Ensure the accurate FEMA 100 year floodplain is shown. The ZMA appeared to show the 500 year. 6. Note 1 on Sheet 4 says no floodplain exists on site, however, a floodplain is shown. Please clarify and correct. 7. SWM facility easements must be shown and recorded with a deed. 11 County of Albemarle Department of Community Development`_ 401 McIntire Road, North Wing Charlottesville, Virginia 22902 PLAN REVIEW COMMENTS - E911 APPLICATION#: SDP201800054 TMP: 04600-00-00-01800 DATE: 7/23/2018 FROM: Elise Kiewra ekiewra@albemarle.org Geographic Data Services (GDS) www.albemarle.org/gds (434) 296-5832 ext. 3030 Acceptable Road Names: NOUSH LN NOUSH CT WESLEY CIR Note: Road names must be on ALL pages of the site plan. However, some things to note: 1. Noush Ln does not have anything addressed off it so it is technically not needed. If you are going to extent it across the road, the road directly across from it on the site plan will also need to be named Noush Ln. 2. It appears all the houses lots 1-15,38-55 appear to be facing Stella Ln. If this is the case they will get Stella Ln addresses. Noush Ct can still be used but nothing will be addressed off it. 3. Same for lots 16-27, if they are facing ROAD E, they will be addressed off that and it will need a road name. 4. If this is the case for these roads you could potentially move Noush Ct to where ROAD E is located and just have Noush Ct be an alley that does not need a name if all the houses are addressed off Stella Ln. A PDF version of the Ordinance and Manual can be found here: httas://www.albemarle.ora/unload/imaaes/Forms Center/Departments/Geoaraphic Data Service s/Forms/Road Namina and Property Numberina Ordinance and Manual.ndf Please consult the County's Road Name Index to check your road names prior to submittal. The Index can be found here: http://www.albemarle.org/albemarle/upload/images/webapps/roads/ Parcel and mapping information can be found here: http://gisweb.albemarle.org/ If you should have any questions, please do not hesitate to contact our office. 11 County of Albemarle Department of Community Development`_ 401 McIntire Road, North Wing Charlottesville, Virginia 22902 PLAN REVIEW COMMENTS - E911 APPLICATION#: SUB201800119 TMP: 04600-00-00-01800 DATE: 7/23/2018 FROM: Elise Kiewra ekiewra@albemarle.org Geographic Data Services (GDS) www.albemarle.org/gds (434) 296-5832 ext. 3030 Acceptable Road Names: NOUSH LN NOUSH CT WESLEY CIR Note: Road names must be on ALL pages of the site plan. However, some things to note: 1. Noush Ln does not have anything addressed off it so it is technically not needed. If you are going to extent it across the road, the road directly across from it on the site plan will also need to be named Noush Ln. 2. It appears all the houses lots 1-15,38-55 appear to be facing Stella Ln. If this is the case they will get Stella Ln addresses. Noush Ct can still be used but nothing will be addressed off it. 3. Same for lots 16-27, if they are facing ROAD E, they will be addressed off that and it will need a road name. 4. If this is the case for these roads you could potentially move Noush Ct to where ROAD E is located and just have Noush Ct be an alley that does not need a name if all the houses are addressed off Stella Ln. A PDF version of the Ordinance and Manual can be found here: httas://www.albemarle.ora/unload/imaaes/Forms Center/Departments/Geoaraphic Data Service s/Forms/Road Namina and Property Numberina Ordinance and Manual.ndf Please consult the County's Road Name Index to check your road names prior to submittal. The Index can be found here: http://www.albemarle.org/albemarle/upload/images/webapps/roads/ Parcel and mapping information can be found here: http://gisweb.albemarle.org/ If you should have any questions, please do not hesitate to contact our office. Review Comments for SDP201800054 Initial Site Plan Project Name: Brookhill - Blk 8B - Initial Date Completed: Monday, August 20. 2018 DepartmentlDivisionlAgency: Review Status: Reviewer: Heather McMahon CDD ARB See Recommendations This item was placed on the CONSENT AGENDA of the 8- 0-18 ARB meeting_ Motion: Mr_ Binsted moved to approve the } consent agenda and forward the recommendations outlined in the staff reports for the Initial Site Plans to the Agent for the Site Review Committee_ as follows_ ARB-2018-102: Brookhill Block 8B — Initial Site Development Plan i.7M.+Parcel 04600000001800) • Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and recommended conditions of initial plan approval: 1_ None_ Note that a Certificate of Appropriateness is required prior to final site plan approval_ Regarding recommendations on the plan as it relates to the guidelines: None_ Regarding conditions to be satisfied prior to issuance of a grading permit: None_ • Regarding the final site plan submittal: 1_ Architecture and landscaping will be reviewed with a future submittal_ A Certificate of Appropriateness is required prior to final site plan approval- _ Provide site sections of Block 8B from the EC to determine visibility of the proposed buildings and site structures- 3- Submit material and color samples, dimensioned elevations of the fagades, and floor plans of the attached multi -family buildings on lots 1-16 and 38-66 for review_ 4_ Provide the standard window glass note on the architectural elevations submitted for review: Window glass in the Entrance Corridors should meet the following criteria: Visible light transmittance (VLT) shall not drop below 40%_ Visible light reflectance (VLR) shall not exceed 30%_ 5_ Provide a roof plan and architectural elevations that show the placement and proposed heights of mechanical units. if roof -mounted mechanical equipment is proposed Shox how all visibility of mechanical equipment from the EC will be eliminated- 6- If above-grorind utilities are proposed, provide these and their easements on revised site plans- 7- I17clrlde the mechanical equipment note on the revised site plans and architectural drawings: Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated- 8- Provide in the site plan sufficient details to show that all proposed light fixtures meet the requirements of the lighting ordinance- 9- Provide a landscape plan for review at a scale of 1° = 30'_ Include utilities and their easements on the plan as }r5,ell as a plant schedule_ 10_ Provide street trees on the east and south sides of Road EAVesley Circle_ 11_ Provide shade trees on the eastern edge of the site around the four parking spaces_ 12_ Provide the standard plant health note on all landscape plans submitted for review: All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited Shrubs and trees shall be pruned minimally and only to support the overall health of the plant_ Page: County of Albemarle Printed On: 0812220'18 Review Comments for SUB201800119 Preliminary Plat Project Name: Erookhill - Blk_ 8B - Preliminary Date Completed: Monday, August 20, 2018 Department1DivisionfAgency: Review Sys: Reviewer: Heather McMahon CBBARB See Recommendations This item was placed on the CONSENT AGENDA of the 8- 0-18 ARB meeting_ Motion: Mr_ Binsted moved to approve the consent agenda and forward the recommendations outlined in the staff reports for the Initial Site Plans to the Agent for the Site Review Committee_ as follows_ ARB-2018-102: Brookhill Block 8B — Initial Site Development Plan i.7M.+Parcel 04600000001800) • Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and recommended conditions of initial plan approval: 1_ None_ Note that a Certificate of Appropriateness is required prior to final site plan approval_ Regarding recommendations on the plan as it relates to the guidelines: None_ Regarding conditions to be satisfied prior to issuance of a grading permit: None_ • Regarding the final site plan submittal: 1_ Architecture and landscaping will be reviewed with a future submittal_ A Certificate of Appropriateness is required prior to final site plan approval- _ Provide site sections of Block 8B from the EC to determine visibility of the proposed buildings and site structures- 3- Submit material and color samples, dimensioned elevations of the fagades, and floor plans of the attached multi -family buildings on lots 1-16 and 38-66 for review_ 4_ Provide the standard window glass note on the architectural elevations submitted for review: Window glass in the Entrance Corridors should meet the following criteria: Visible light transmittance (VLT) shall not drop below 40%_ Visible light reflectance (VLR) shall not exceed 30%_ 5_ Provide a roof plan and architectural elevations that show the placement and proposed heights of mechanical units. if roof -mounted mechanical equipment is proposed Shox how all visibility of mechanical equipment from the EC will be eliminated- 6- If above-grOLInd utilities are proposed, provide these and their easements on revised site plans- 7- I11CILIde the mechanical equipment note on the revised site plans and architectural drawings: Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated- 8- Provide in the site plan sufficient details to show that all proposed light fixtures meet the requirements of the lighting ordinance- 9- Provide a landscape plan for review at a scale of 1° = 30'_ Include utilities and their easements on the plan as }r5,ell as a plant schedule_ 10_ Provide street trees on the east and south sides of Road EAVesley Circle_ 11_ Provide shade trees on the eastern edge of the site around the four parking spaces_ 12_ Provide the standard plant health note on all landscape plans submitted for review: All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited Shrubs and trees shall be pruned minimally and only to support the overall health of the plant_ Page: County of Albemarle Printed On: 0812220'18 Cameron Langille From: Richard Nelson <rnelson@serviceauthority.org> Sent: Wednesday, July 25, 2018 11:22 AM To: Cameron Langille Subject: SDP201800054 and SUB201800119 - Brookhill Block 8B - Preliminary and Initial Cameron, I recommend SDP201800054 and SUB201800119 - Brookhill Block 8B - Preliminary and Initial for approval. A revised master plan and updated hydraulic model will be required prior to final approval (which will be provided by the applicant for plans currently under review). Submit 3 copies of site plan to ACSA for water and sewer review. RWSA sewer flow capacity will be required prior to final approval. Thanks, Richard Nelson Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (434) 977-4511 Stephen C. Brich, P.E. Commissioner COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper, Virginia 22701 August 16, 2018 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Cameron Langille Re: Brookhill Block 8B — Preliminary Plat & Initial Site Plan SUB-2018-00119 SDP-2018-00054 Review #1 Dear Mr. Langille: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plans as submitted by Collins Engineering, dated 25 June 2018, and offers the following comments: 1. The entrance on to the proposed public road at the northern end of the site does not appear to meet corner clearance requirements. This entrance does not appear on the SUB201800115 plan, as noted on this plan. 2. Provide intersection site distance lines and profiles for all public road intersections and entrances. 3. Note that the final site and subdivision plans must show conformance with the VDOT Road Design Manual Appendices B(1) and F, as well as any other applicable standards, regulations or other requirements. Please provide two copies of the revised plan along with a comment response letter. If further information is desired, please contact Justin Deel at 434-422-9894. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the Charlottesville Residency Transportation and Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, �]' c PA -- Adam J. oore, P.E. Area Land Use Engineer Charlottesville Residency VirginiaDOT.org WE KEEP VIRGINIA MOVING Review Comments for SDP201800054 11nitial Site Plan Project Name: Brookhill - Blk 8B - Initial Date Completed: Thursday, August 30, 2018 Department1DivisionfAgency: Review Sys: Reviewer: Shawn Maddox F Fire Rescue Requested Changes E 1 _ Noush Court does net meet the minimum 0' of clear travel width_ If this private street is going to serve as a primary means of access for any dwelling units it must be increased in width- _ Streets with 20' or less of clear unobstructed travel width must be marked no parking on one side_ Please ensure street parking is marked appropriately throughout this phase- 3- Add a hydrant in the area of Lot 1 or 16_ Based on the current layout use of a hydrant sho}xii on the plan could potentially restrict any other vehicular traffic in this phase- 4- As these phases are approved and constructed please keep in mind that if a travel way exceeds 150' in length and the proposed road connections are not made then an approved emergency apparatus turn around must be provided_ Any questions, or necessary coordination, can be directed to the fire marshal's office- 5- No hydrants shown on sheet 6A, one should be added in this block unless spacing is verified Page: County of Albemarle Printed On: 10910612018 MANAGER, OPERATIONS PROGRAM SUPPORT UNITED STATES POSTAL SERVICE 10LINITED STATES — POST13L SERVICE Date: November 23,2015 Subject: New Developments In April 2012, the USPS revised regulation to clarify options for delivery and to provide the USPS greater autonomy in determining how deliveries are added to the Postal Service network. While curbline and sidewalk delivery remain viable and approved modes of delivery, the USPS will determine how and when to approve these modes of delivery consistent with existing Postal Operations Manual (POM) regulation regarding in -growth and both establishment and extension of delivery. Each year, new delivery addresses are added to our city, rual and contract routes which has a major impact to our delivery cost. To control costs, we need to ensure new residential deliveries are being made via centralized delivery. We must adhere to the guidelines that govern establishment of new delivery. The City/County authorities (Planning and Zoning) can not give approval of delivery service. The Postal Service cannot honor agreements that have been made between Planning and Zoning and the developer. At a minimum, the USPS will work with the builders and developers to determine what the best mode of delivery is for the area prior to establishing or extending delivery service. However, as a national agency, the USPS reserves the right to establish delivery in the most consistent and cost effective means viable to meet our federal mandate of providing a free form of service that best meets the need to establish and maintain a safe, reliable and efficient national Postal Service. Please review the changes to the POM regarding Modes of Delivery and Delivery Equipment. The changes are designed to enhance our ability to increase centralized and CBU delivery. • Centralized and CBU delivery is now the default mode of delivery in business areas. Any exceptions to centralized or CBU delivery mode in business areas must be approved by the District. (631.2) • For new residential delivery, CBU is now the default. Exceptions to permit curbline delivery must be approved by the District. (631.32) • New deliveries within an existing block with an established mode of delivery no longer assume the existing mode of delivery. We can require a more efficient mode of delivery (sidewalk delivery, for example). (631.41) • While we do not control addresses for buildings, we do control the sequential ordering of addresses within any centralized delivery equipment. (631.442) • If more than one building in a complex has the same street address, the delivery equipment must be grouped at a single location even if some of the units are in a different building. (631.452) -2- • Centralized delivery or CBU is the default option for delivery in mobile homes or trailer parks that are permanent residences. Any exceptions to centralized or CBU delivery mode must be approved by the District (631.462b) • For dormitories and residence halls not directly affiliated with colleges, the Postal Service determines the mode of delivery and can require the property owner to accept mail for all the tenants. We will not distribute mail into centralized delivery equipment. (631.52) • Delivery equipment must conform with the USPS standards for CBUs and high-rise delivery equipment, USPS STD 4C wall mounted mail receptacles. Local offices do not have the authority to approve any other centralized delivery equipment. (631.441) • When obsolete delivery equipment is replaced in multi -unit buildings, it must be replaced with equipment that meets current standards. (632.621) The USPS standards include options for parcel lockers that we should ensure are provided. There was also great consideration regarding safety of delivery, which also resulted in the determination the the type of delivery warrented in your area. APPROVALS DATE DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNER/ZONING ENGINEER INSPECTIONS ARB DEPARTMENT OF FIRE RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARMENT OF TRANSPORTATION HEALTH DEPARTMENT